569 related articles for article (PubMed ID: 21246378)
1. Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups.
Mulier M; Jaecques SV; Raaijmaakers M; Nijs J; Van der Perre G; Jonkers I
Arch Orthop Trauma Surg; 2011 Jul; 131(7):941-8. PubMed ID: 21246378
[TBL] [Abstract][Full Text] [Related]
2. Unstable versus stable uncemented femoral stems: a radiological study of periprosthetic bone changes in two types of uncemented stems with different concepts of fixation.
Bodén H; Adolphson P; Oberg M
Arch Orthop Trauma Surg; 2004 Jul; 124(6):382-92. PubMed ID: 15112084
[TBL] [Abstract][Full Text] [Related]
3. Different loss of BMD using uncemented press-fit and whole polyethylene cups fixed with cement: repeated DXA studies in 96 hips randomized to 3 types of fixation.
Digas G; Kärrholm J; Thanner J
Acta Orthop; 2006 Apr; 77(2):218-26. PubMed ID: 16752282
[TBL] [Abstract][Full Text] [Related]
4. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.
Digas G
Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289
[TBL] [Abstract][Full Text] [Related]
5. [A comparative study on short-term effectiveness between cemented and uncemented total hip arthroplasty for osteonecrosis of femoral head after renal transplantation].
Yu L; Qi C; Yu T; Meng Q; Zhao X; Liu K; Cai Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1409-13. PubMed ID: 24640354
[TBL] [Abstract][Full Text] [Related]
6. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.
Bidar R; Kouyoumdjian P; Munini E; Asencio G
Orthop Traumatol Surg Res; 2009 Dec; 95(8):579-87. PubMed ID: 19926546
[TBL] [Abstract][Full Text] [Related]
7. Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: a prospective study using computed tomography-assisted osteodensitometry.
Mueller LA; Schmidt R; Ehrmann C; Nowak TE; Kress A; Forst R; Pfander D
J Orthop Res; 2009 Feb; 27(2):176-82. PubMed ID: 18752277
[TBL] [Abstract][Full Text] [Related]
8. The uncemented isoelastic/isotitan total hip arthroplasty. A 10-15 years follow-up with bone mineral density evaluation.
Nagi ON; Kumar S; Aggarwal S
Acta Orthop Belg; 2006 Jan; 72(1):55-64. PubMed ID: 16570896
[TBL] [Abstract][Full Text] [Related]
9. Clinical outcome and quantitative evaluation of periprosthetic bone-remodeling of an uncemented femoral component with taper design. A prospective study.
Pitto RP; Schramm M; Hohmann D; Schmidt R
Chir Organi Mov; 2001; 86(2):87-97. PubMed ID: 12025051
[TBL] [Abstract][Full Text] [Related]
10. Primary aseptic revision of the femoral component of a cemented total hip arthroplasty using a cemented technique without bone graft.
Bardou-Jacquet J; Souillac V; Mouton A; Chauveaux D
Orthop Traumatol Surg Res; 2009 Jun; 95(4):243-8. PubMed ID: 19523892
[TBL] [Abstract][Full Text] [Related]
11. [Oblong acetabular cup, type TC, for revision total hip arthroplasty].
Trč T; Stastný E
Acta Chir Orthop Traumatol Cech; 2012; 79(6):506-11. PubMed ID: 23286682
[TBL] [Abstract][Full Text] [Related]
12. [Influence of the Type of Hip-Component Fixation and Age of Patients on Mid-Term Revision Rate of Total Hip Replacement].
Kubinec V
Acta Chir Orthop Traumatol Cech; 2018; 85(1):46-53. PubMed ID: 30257769
[TBL] [Abstract][Full Text] [Related]
13. Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss.
Rahmy AI; Gosens T; Blake GM; Tonino A; Fogelman I
Osteoporos Int; 2004 Apr; 15(4):281-9. PubMed ID: 14661072
[TBL] [Abstract][Full Text] [Related]
14. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.
Finnilä S; Moritz N; SvedströM E; Alm JJ; Aro HT
Acta Orthop; 2016 Feb; 87(1):48-54. PubMed ID: 26569616
[TBL] [Abstract][Full Text] [Related]
15. Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.
Beldame J; Carreras F; Oger P; Beaufils P
Orthop Traumatol Surg Res; 2009 Nov; 95(7):478-90. PubMed ID: 19801209
[TBL] [Abstract][Full Text] [Related]
16. Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.
Bjerkholt H; Høvik O; Reikerås O
J Orthop Traumatol; 2010 Sep; 11(3):155-8. PubMed ID: 20811923
[TBL] [Abstract][Full Text] [Related]
17. [Use of uncemented Beznoska acetabular cup - mid-term results at the orthopedic ward in Pelhrimov].
Letocha J; Behounek J; Skoták M
Acta Chir Orthop Traumatol Cech; 2007 Jun; 74(3):195-201. PubMed ID: 17623608
[TBL] [Abstract][Full Text] [Related]
18. Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.
Hailer NP; Garellick G; Kärrholm J
Acta Orthop; 2010 Feb; 81(1):34-41. PubMed ID: 20180715
[TBL] [Abstract][Full Text] [Related]
19. Obesity, age, sex, diagnosis, and fixation mode differently affect early cup failure in total hip arthroplasty: a matched case-control study of 4420 patients.
Röder C; Bach B; Berry DJ; Eggli S; Langenhahn R; Busato A
J Bone Joint Surg Am; 2010 Aug; 92(10):1954-63. PubMed ID: 20720138
[TBL] [Abstract][Full Text] [Related]
20. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]