BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 21248391)

  • 1. Bias in iterative reconstruction of low-statistics PET data: benefits of a resolution model.
    Walker MD; Asselin MC; Julyan PJ; Feldmann M; Talbot PS; Jones T; Matthews JC
    Phys Med Biol; 2011 Feb; 56(4):931-49. PubMed ID: 21248391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of methods for quantification of rCBF using high-resolution [¹⁵O]H₂O PET images.
    Walker MD; Feldmann M; Matthews JC; Anton-Rodriguez JM; Wang S; Koepp MJ; Asselin MC
    Phys Med Biol; 2012 Apr; 57(8):2251-71. PubMed ID: 22455998
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of image-space resolution modeling for studies with the high-resolution research tomograph.
    Sureau FC; Reader AJ; Comtat C; Leroy C; Ribeiro MJ; Buvat I; Trébossen R
    J Nucl Med; 2008 Jun; 49(6):1000-8. PubMed ID: 18511844
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Studying the properties of the updating coefficients in the OSEM algorithm for iterative image reconstruction in PET.
    Gaitanis A; Kontaxakis G; Spyrou G; Panayiotakis G; Tzanakos G
    Comput Methods Programs Biomed; 2010 Sep; 99(3):219-29. PubMed ID: 20083322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method for accurate modelling of the crystal response function at a crystal sub-level applied to PET reconstruction.
    Stute S; Benoit D; Martineau A; Rehfeld NS; Buvat I
    Phys Med Biol; 2011 Feb; 56(3):793-809. PubMed ID: 21239844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of the injected activity in dynamic 3D PET: a generalized approach using patient-specific NECs as demonstrated by a series of 15O-H2O scans.
    Walker MD; Matthews JC; Asselin MC; Saleem A; Dickinson C; Charnley N; Julyan PJ; Price PM; Jones T
    J Nucl Med; 2009 Sep; 50(9):1409-17. PubMed ID: 19690021
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method.
    Kudomi N; Watabe H; Hayashi T; Iida H
    Phys Med Biol; 2007 Apr; 52(7):1893-908. PubMed ID: 17374918
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time iterative monitoring of radiofrequency ablation tumor therapy with 15O-water PET imaging.
    Bao A; Goins B; Dodd GD; Soundararajan A; Santoyo C; Otto RA; Davis MD; Phillips WT
    J Nucl Med; 2008 Oct; 49(10):1723-9. PubMed ID: 18794264
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph.
    van Velden FH; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R
    J Nucl Med; 2009 Jan; 50(1):72-80. PubMed ID: 19091902
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fully 4D list-mode reconstruction applied to respiratory-gated PET scans.
    Grotus N; Reader AJ; Stute S; Rosenwald JC; Giraud P; Buvat I
    Phys Med Biol; 2009 Mar; 54(6):1705-21. PubMed ID: 19242055
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A new Bayesian reconstruction algorithm for PET images based on correction of the detected sinogram data].
    Chen Y; Wang QQ; Huang ZY; Chen WF
    Nan Fang Yi Ke Da Xue Xue Bao; 2007 Mar; 27(3):325-8. PubMed ID: 17425984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multi-ray-based system matrix generation for 3D PET reconstruction.
    Moehrs S; Defrise M; Belcari N; Guerra AD; Bartoli A; Fabbri S; Zanetti G
    Phys Med Biol; 2008 Dec; 53(23):6925-45. PubMed ID: 19001696
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of bias and variance in low-count OSEM list mode reconstruction.
    Jian Y; Planeta B; Carson RE
    Phys Med Biol; 2015 Jan; 60(1):15-29. PubMed ID: 25479254
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PET image reconstruction: A stopping rule for the MLEM algorithm based on properties of the updating coefficients.
    Gaitanis A; Kontaxakis G; Spyrou G; Panayiotakis G; Tzanakos G
    Comput Med Imaging Graph; 2010 Mar; 34(2):131-41. PubMed ID: 19744826
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of analytical reconstruction with a new gap-filling method in comparison to iterative reconstruction in [¹¹C]-raclopride PET studies.
    Tuna U; Johansson J; Ruotsalainen U
    Ann Nucl Med; 2014 Jun; 28(5):417-29. PubMed ID: 24647993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels.
    Vandenberghe S; Staelens S; Byrne CL; Soares EJ; Lemahieu I; Glick SJ
    Phys Med Biol; 2006 Jun; 51(12):3105-25. PubMed ID: 16757866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET.
    Ortuño JE; Kontaxakis G; Rubio JL; Guerra P; Santos A
    Phys Med Biol; 2010 Apr; 55(7):1833-61. PubMed ID: 20224156
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Statistical dynamic image reconstruction in state-of-the-art high-resolution PET.
    Rahmim A; Cheng JC; Blinder S; Camborde ML; Sossi V
    Phys Med Biol; 2005 Oct; 50(20):4887-912. PubMed ID: 16204879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE.
    Lamare F; Turzo A; Bizais Y; Le Rest CC; Visvikis D
    Phys Med Biol; 2006 Feb; 51(4):943-62. PubMed ID: 16467589
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM.
    Reader AJ; Sureau FC; Comtat C; Trébossen R; Buvat I
    Phys Med Biol; 2006 Nov; 51(21):5455-74. PubMed ID: 17047263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.