BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 21248694)

  • 1. Tri-layered electrospinning to mimic native arterial architecture using polycaprolactone, elastin, and collagen: a preliminary study.
    McClure MJ; Sell SA; Simpson DG; Walpoth BH; Bowlin GL
    J Vis Exp; 2011 Jan; (47):. PubMed ID: 21248694
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A three-layered electrospun matrix to mimic native arterial architecture using polycaprolactone, elastin, and collagen: a preliminary study.
    McClure MJ; Sell SA; Simpson DG; Walpoth BH; Bowlin GL
    Acta Biomater; 2010 Jul; 6(7):2422-33. PubMed ID: 20060934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tri-layered vascular grafts composed of polycaprolactone, elastin, collagen, and silk: Optimization of graft properties.
    McClure MJ; Simpson DG; Bowlin GL
    J Mech Behav Biomed Mater; 2012 Jun; 10():48-61. PubMed ID: 22520418
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrospun polydioxanone-elastin blends: potential for bioresorbable vascular grafts.
    Sell SA; McClure MJ; Barnes CP; Knapp DC; Walpoth BH; Simpson DG; Bowlin GL
    Biomed Mater; 2006 Jun; 1(2):72-80. PubMed ID: 18460759
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Engineering poly(hydroxy butyrate-co-hydroxy valerate) based vascular scaffolds to mimic native artery.
    Deepthi S; Nivedhitha Sundaram M; Vijayan P; Nair SV; Jayakumar R
    Int J Biol Macromol; 2018 Apr; 109():85-98. PubMed ID: 29247731
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The mechanical performance of weft-knitted/electrospun bilayer small diameter vascular prostheses.
    Xie Y; Guan Y; Kim SH; King MW
    J Mech Behav Biomed Mater; 2016 Aug; 61():410-418. PubMed ID: 27111627
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Controlled fabrication of triple layered and molecularly defined collagen/elastin vascular grafts resembling the native blood vessel.
    Koens MJ; Faraj KA; Wismans RG; van der Vliet JA; Krasznai AG; Cuijpers VM; Jansen JA; Daamen WF; van Kuppevelt TH
    Acta Biomater; 2010 Dec; 6(12):4666-74. PubMed ID: 20619367
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrochemical fabrication of a biomimetic elastin-containing bi-layered scaffold for vascular tissue engineering.
    Nguyen TU; Shojaee M; Bashur CA; Kishore V
    Biofabrication; 2018 Nov; 11(1):015007. PubMed ID: 30411718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and comprehensive assessment of a biomimetic tri-layer tubular scaffold via biodegradable polymers for vascular tissue engineering applications.
    Jia W; Li M; Weng H; Gu G; Chen Z
    Mater Sci Eng C Mater Biol Appl; 2020 May; 110():110717. PubMed ID: 32204029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vascular replacement using a layered elastin-collagen vascular graft in a porcine model: one week patency versus one month occlusion.
    Koens MJ; Krasznai AG; Hanssen AE; Hendriks T; Praster R; Daamen WF; van der Vliet JA; van Kuppevelt TH
    Organogenesis; 2015; 11(3):105-21. PubMed ID: 26060888
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acellular vascular grafts generated from collagen and elastin analogs.
    Kumar VA; Caves JM; Haller CA; Dai E; Liu L; Grainger S; Chaikof EL
    Acta Biomater; 2013 Sep; 9(9):8067-74. PubMed ID: 23743129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elasticity assessment of electrospun nanofibrous vascular grafts: a comparison with femoral ovine arteries.
    Bagnasco DS; Ballarin FM; Cymberknop LJ; Balay G; Negreira C; Abraham GA; Armentano RL
    Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():446-54. PubMed ID: 25491850
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrospinning collagen/chitosan/poly(L-lactic acid-co-ε-caprolactone) to form a vascular graft: mechanical and biological characterization.
    Yin A; Zhang K; McClure MJ; Huang C; Wu J; Fang J; Mo X; Bowlin GL; Al-Deyab SS; El-Newehy M
    J Biomed Mater Res A; 2013 May; 101(5):1292-301. PubMed ID: 23065755
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrospun Tissue-Engineered Arterial Graft Thickness Affects Long-Term Composition and Mechanics.
    Wu YL; Szafron JM; Blum KM; Zbinden JC; Khosravi R; Best CA; Reinhardt JW; Zeng Q; Yi T; Shinoka T; Humphrey JD; Breuer CK; Wang Y
    Tissue Eng Part A; 2021 May; 27(9-10):593-603. PubMed ID: 32854586
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coaxially-structured fibres with tailored material properties for vascular graft implant.
    Johnson R; Ding Y; Nagiah N; Monnet E; Tan W
    Mater Sci Eng C Mater Biol Appl; 2019 Apr; 97():1-11. PubMed ID: 30678891
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Towards compliant small-diameter vascular grafts: Predictive analytical model and experiments.
    Bouchet M; Gauthier M; Maire M; Ajji A; Lerouge S
    Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():715-723. PubMed ID: 30948109
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrospun PET/PCL small diameter nanofibrous conduit for biomedical application.
    Rahmati Nejad M; Yousefzadeh M; Solouk A
    Mater Sci Eng C Mater Biol Appl; 2020 May; 110():110692. PubMed ID: 32204006
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fabrication and modification of wavy multicomponent vascular grafts with biomimetic mechanical properties, antithrombogenicity, and enhanced endothelial cell affinity.
    Mi HY; Jing X; Li ZT; Lin YJ; Thomson JA; Turng LS
    J Biomed Mater Res B Appl Biomater; 2019 Oct; 107(7):2397-2408. PubMed ID: 30689292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical and biocompatible characterizations of a readily available multilayer vascular graft.
    Madhavan K; Elliott WH; Bonani W; Monnet E; Tan W
    J Biomed Mater Res B Appl Biomater; 2013 May; 101(4):506-19. PubMed ID: 23165922
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Functionally graded electrospun scaffolds with tunable mechanical properties for vascular tissue regeneration.
    Thomas V; Zhang X; Catledge SA; Vohra YK
    Biomed Mater; 2007 Dec; 2(4):224-32. PubMed ID: 18458479
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.