BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 21255488)

  • 1. Experience with a new device for clearing mucus from the endotracheal tube.
    Stone RH; Bricknell SS
    Respir Care; 2011 Apr; 56(4):520-2. PubMed ID: 21255488
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Removal of endotracheal tube obstruction with a secretion clearance device.
    Mietto C; Foley K; Salerno L; Oleksak J; Pinciroli R; Goverman J; Berra L
    Respir Care; 2014 Sep; 59(9):e122-6. PubMed ID: 24368863
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Endotracheal Tube Scraping on Airway Resistance.
    Scott JB; Dubosky MN; Vines DL; Sulaiman AS; Jendral KR; Singh G; Patel A; Kaplan CA; Gurka DP; Balk RA
    Respir Care; 2017 Nov; 62(11):1423-1427. PubMed ID: 28790149
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 72-hour study to test the efficacy and safety of the "Mucus Slurper" in mechanically ventilated sheep.
    Li Bassi G; Curto F; Zanella A; Stylianou M; Kolobow T
    Crit Care Med; 2007 Mar; 35(3):906-11. PubMed ID: 17255853
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of endotracheal tube obstruction by analysis of the expiratory flow signal.
    Guttmann J; Eberhard L; Haberthür C; Mols G; Kessler V; Lichtwarck-Aschoff M; Geiger K
    Intensive Care Med; 1998 Nov; 24(11):1163-72. PubMed ID: 9876979
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of partial endotracheal tube obstruction by forced pressure oscillations.
    Schumann S; Lichtwarck-Aschoff M; Haberthür C; Stahl CA; Möller K; Guttmann J
    Respir Physiol Neurobiol; 2007 Mar; 155(3):227-33. PubMed ID: 16861058
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Acoustic method to estimate the longitudinal area profile of endotracheal tubes.
    Van Surell C; Louis B; Lofaso F; Beydon L; Brochard L; Harf A; Fredberg J; Isabey D
    Am J Respir Crit Care Med; 1994 Jan; 149(1):28-33. PubMed ID: 8111593
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Blind intubation device for nasotracheal intubation in 100 oral and maxillofacial surgery patients with anticipated difficult airways: a prospective evaluation.
    Sun Y; Jiang H; Zhu Y; Xu H; Huang Y
    Eur J Anaesthesiol; 2009 Sep; 26(9):746-51. PubMed ID: 19451824
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endotracheal Tubes Cleaned With a Novel Mechanism for Secretion Removal: A Randomized Controlled Clinical Study.
    Pinciroli R; Mietto C; Piriyapatsom A; Chenelle CT; Thomas JG; Pirrone M; Bry L; Wojtkiewicz GR; Nahrendorf MP; Kacmarek RM; Berra L
    Respir Care; 2016 Nov; 61(11):1431-1439. PubMed ID: 27460104
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Airway obstruction caused by endotracheal tube cuff herniation during creation of tracheal stoma.
    Kao MC; Yu YS; Liu HT; Tsai SK; Lin SM; Huang YC
    Acta Anaesthesiol Taiwan; 2005 Mar; 43(1):59-62. PubMed ID: 15869007
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Changes in resistances of endotracheal tubes with reductions in the cross-sectional area.
    El-Khatib MF; Husari A; Jamaleddine GW; Ayoub CM; Bou-Khalil P
    Eur J Anaesthesiol; 2008 Apr; 25(4):275-9. PubMed ID: 18177540
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Change in expiratory flow detects partial endotracheal tube obstruction in pressure-controlled ventilation.
    Kawati R; Vimlati L; Guttmann J; Hedenstierna G; Sjöstrand U; Schumann S; Lichtwarck-Aschoff M
    Anesth Analg; 2006 Sep; 103(3):650-7. PubMed ID: 16931676
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnosing partially obstructed endotracheal tubes: the advent of intelligent ventilator monitors.
    Simpson SQ
    Crit Care Med; 2005 Jan; 33(1):249-50. PubMed ID: 15644688
    [No Abstract]   [Full Text] [Related]  

  • 14. Endotracheal Tube Obstruction Among Patients Mechanically Ventilated for ARDS Due to COVID-19: A Case Series.
    Wiles S; Mireles-Cabodevila E; Neuhofs S; Mukhopadhyay S; Reynolds JP; Hatipoğlu U
    J Intensive Care Med; 2021 May; 36(5):604-611. PubMed ID: 33375893
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stenting allows weaning and extubation in ventilator- or tracheostomy dependency secondary to benign airway disease.
    Noppen M; Stratakos G; Amjadi K; De Weerdt S; D'Haese J; Meysman M; Vincken W
    Respir Med; 2007 Jan; 101(1):139-45. PubMed ID: 16709452
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Devices for difficult airway management in academic emergency departments: results of a national survey.
    Levitan RM; Kush S; Hollander JE
    Ann Emerg Med; 1999 Jun; 33(6):694-8. PubMed ID: 10339685
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A defective endotracheal tube.
    Chua WL; Ng AS
    Singapore Med J; 2002 Sep; 43(9):476-8. PubMed ID: 12568427
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Micropatterned Endotracheal Tubes Reduce Secretion-Related Lumen Occlusion.
    Mann EE; Magin CM; Mettetal MR; May RM; Henry MM; DeLoid H; Prater J; Sullivan L; Thomas JG; Twite MD; Parker AE; Brennan AB; Reddy ST
    Ann Biomed Eng; 2016 Dec; 44(12):3645-3654. PubMed ID: 27535564
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Miniature acoustic guidance system for endotracheal tubes.
    Juan EJ; Mansfield JP; Wodicka GR
    IEEE Trans Biomed Eng; 2002 Jun; 49(6):584-96. PubMed ID: 12046704
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fatal endotracheal tube obstruction due to the ball valve effect.
    Woittiez KJ; Woittiez AJ
    BMJ Case Rep; 2015 Jan; 2015():. PubMed ID: 25618886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.