These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
231 related articles for article (PubMed ID: 21257372)
21. Force-Sensorless Identification and Classification of Tissue Biomechanical Parameters for Robot-Assisted Palpation. Gutierrez-Giles A; Padilla-CastaƱeda MA; Alvarez-Icaza L; Gutierrez-Herrera E Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433266 [TBL] [Abstract][Full Text] [Related]
22. Viscoelastic characterization of the primate finger pad in vivo by microstep indentation and three-dimensional finite element models for tactile sensation studies. Kumar S; Liu G; Schloerb DW; Srinivasan MA J Biomech Eng; 2015 Jun; 137(6):061002. PubMed ID: 25751365 [TBL] [Abstract][Full Text] [Related]
23. Input and output for surgical simulation: devices to measure tissue properties in vivo and a haptic interface for laparoscopy simulators. Ottensmeyer MP; Ben-Ur E; Salisbury JK Stud Health Technol Inform; 2000; 70():236-42. PubMed ID: 10977548 [TBL] [Abstract][Full Text] [Related]
24. Parameter identification of hyperelastic material properties of the heel pad based on an analytical contact mechanics model of a spherical indentation. Suzuki R; Ito K; Lee T; Ogihara N J Mech Behav Biomed Mater; 2017 Jan; 65():753-760. PubMed ID: 27764748 [TBL] [Abstract][Full Text] [Related]
25. The development of a material model and wheel-tissue interaction for simulating wheeled surgical robot mobility. Rentschler ME; Reid JD Comput Methods Biomech Biomed Engin; 2009 Apr; 12(2):239-48. PubMed ID: 19012064 [TBL] [Abstract][Full Text] [Related]
26. Finite element modeling of haptic thermography: A novel approach for brain tumor detection during minimally invasive neurosurgery. Sadeghi-Goughari M; Mojra A J Therm Biol; 2015 Oct; 53():53-65. PubMed ID: 26590456 [TBL] [Abstract][Full Text] [Related]
27. Air-float palpation probe for tissue abnormality identification during minimally invasive surgery. Wanninayake IB; Dasgupta P; Seneviratne LD; Althoefer K IEEE Trans Biomed Eng; 2013 Oct; 60(10):2735-44. PubMed ID: 23708764 [TBL] [Abstract][Full Text] [Related]
28. Artificial palpation in robotic surgery using haptic feedback. Abiri A; Juo YY; Tao A; Askari SJ; Pensa J; Bisley JW; Dutson EP; Grundfest WS Surg Endosc; 2019 Apr; 33(4):1252-1259. PubMed ID: 30187198 [TBL] [Abstract][Full Text] [Related]
29. Using visual cues to enhance haptic feedback for palpation on virtual model of soft tissue. Li M; Konstantinova J; Secco EL; Jiang A; Liu H; Nanayakkara T; Seneviratne LD; Dasgupta P; Althoefer K; Wurdemann HA Med Biol Eng Comput; 2015 Nov; 53(11):1177-86. PubMed ID: 26018755 [TBL] [Abstract][Full Text] [Related]
30. A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue. Han L; Noble JA; Burcher M Ultrasound Med Biol; 2003 Jun; 29(6):813-23. PubMed ID: 12837497 [TBL] [Abstract][Full Text] [Related]
31. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model. Li M; Konstantinova J; Xu G; He B; Aminzadeh V; Xie J; Wurdemann H; Althoefer K PLoS One; 2017; 12(3):e0172703. PubMed ID: 28248996 [TBL] [Abstract][Full Text] [Related]
32. A Survey on Force Sensing Techniques in Robot-Assisted Minimally Invasive Surgery. Wang W; Wang J; Luo Y; Wang X; Song H IEEE Trans Haptics; 2023; 16(4):702-718. PubMed ID: 37922188 [TBL] [Abstract][Full Text] [Related]
33. Estimation of the hyperelastic parameters of fresh human oropharyngeal soft tissues using indentation testing. Haddad SMH; Dhaliwal SS; Rotenberg BW; Ladak HM; Samani A J Mech Behav Biomed Mater; 2020 Aug; 108():103798. PubMed ID: 32469719 [TBL] [Abstract][Full Text] [Related]
34. Behavioral characteristics of manual palpation to localize hard nodules in soft tissues. Konstantinova J; Li M; Mehra G; Dasgupta P; Althoefer K; Nanayakkara T IEEE Trans Biomed Eng; 2014 Jun; 61(6):1651-9. PubMed ID: 24845274 [TBL] [Abstract][Full Text] [Related]
35. Evaluating tactile feedback in robotic surgery for potential clinical application using an animal model. Wottawa CR; Genovese B; Nowroozi BN; Hart SD; Bisley JW; Grundfest WS; Dutson EP Surg Endosc; 2016 Aug; 30(8):3198-209. PubMed ID: 26514132 [TBL] [Abstract][Full Text] [Related]
36. The MUSHA underactuated hand for robot-aided minimally invasive surgery. Selvaggio M; Fontanelli GA; Marrazzo VR; Bracale U; Irace A; Breglio G; Villani L; Siciliano B; Ficuciello F Int J Med Robot; 2019 Jun; 15(3):e1981. PubMed ID: 30588772 [TBL] [Abstract][Full Text] [Related]
37. Video-tactile pneumatic sensor for soft tissue elastic modulus estimation. Gubenko MM; Morozov AV; Lyubicheva AN; Goryacheva IG; Dosaev MZ; Ju MS; Yeh CH; Su FC Biomed Eng Online; 2017 Aug; 16(1):94. PubMed ID: 28764711 [TBL] [Abstract][Full Text] [Related]
38. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery. Moradi Dalvand M; Shirinzadeh B; Shamdani AH; Smith J; Zhong Y Int J Med Robot; 2014 Mar; 10(1):11-21. PubMed ID: 23640908 [TBL] [Abstract][Full Text] [Related]
39. Mechanical modeling and characterization of meniscus tissue using flat punch indentation and inverse finite element method. Seyfi B; Fatouraee N; Imeni M J Mech Behav Biomed Mater; 2018 Jan; 77():337-346. PubMed ID: 28965040 [TBL] [Abstract][Full Text] [Related]
40. Mechanical response of brain to mechanical stimuli--animal model investigation. Szotek S; Kobielarz M; Maksymowicz K Neurol Neurochir Pol; 2007; 41(6):525-32. PubMed ID: 18224575 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]