These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 21258307)

  • 21. Evaluation of the microcolumn technology for pretransfusion testing in multiple myeloma patients.
    Fabijańska-Mitek J; Zupańska B; Pogłód R; Gorajek M; Lopieńska H; Kraj M
    Vox Sang; 1998; 74(1):31-5. PubMed ID: 9481858
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of conventional tube test with diamed gel microcolumn assay for anti-D titration.
    Novaretti MC; Jens E; Pagliarini T; Bonifácio SL; Dorlhiac-Llacer PE; Chamone DA
    Clin Lab Haematol; 2003 Oct; 25(5):311-5. PubMed ID: 12974722
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Drug-induced immune hemolytic anemia investigation: Comparison between tube test and microcolumn agglutination (gel test) for the detection of drug-dependent antibodies in the presence of soluble drug.
    Nguyen TN; Fihman V; Maenulein E; Vinatier I; Klaren JM
    Transfus Clin Biol; 2020 Aug; 27(3):133-138. PubMed ID: 32561329
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Comparative study of antibody identification in the gel centrifugation test (ID Microtyping System), solid phase antiglobulin test (Solidscreen Capture R, Ready ID) and tube test].
    Hitzler W; Johanson C; Schömig-Brekner J; Mathias D
    Beitr Infusionsther; 1992; 30():370-4. PubMed ID: 1284737
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anti-A antibody transfused with non-group-specific platelets. Serological abnormalities.
    Thomas L; Tuscany FL; Wilner GD
    Arch Pathol Lab Med; 1981 Jan; 105(1):52-3. PubMed ID: 6893913
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Effect of HLA antibodies on the gel centrifugation test].
    Stangenberg W; Kretschmer V; Ponath N
    Beitr Infusionsther Transfusionsmed; 1996; 33():43-6. PubMed ID: 8974707
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Polyethylene glycol antiglobulin tube versus gel microcolumn: influence on the incidence of delayed hemolytic transfusion reactions and delayed serologic transfusion reactions.
    Winters JL; Richa EM; Bryant SC; Tauscher CD; Bendix BJ; Stubbs JR
    Transfusion; 2010 Jul; 50(7):1444-52. PubMed ID: 20230534
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.
    Villarnovo D; Burton SA; Horney BS; MacKenzie AL; Vanderstichel R
    Vet Clin Pathol; 2016 Sep; 45(3):411-6. PubMed ID: 27378560
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The evolution of pretransfusion testing: from agglutination to solid-phase red cell adherence tests.
    Plapp FV; Sinor LT; Rachel JM
    Crit Rev Clin Lab Sci; 1989; 27(2):179-209. PubMed ID: 2656094
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The gel test: investigation into the aetiology and the significance of a positive auto-control.
    Eichler H; Kretschmer V
    Infusionsther Transfusionsmed; 1995 Aug; 22(4):232-6. PubMed ID: 7496122
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Observations on antibody determination and differentiation with papain test erythrocytes using the gel centrifugation technique (ID-Microtyping System)].
    Strobel E; Wüllenweber J
    Infusionsther Transfusionsmed; 1995 Feb; 22(1):25-30. PubMed ID: 7727960
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [The "Eilbek capillary"--a new immune hematologic technic].
    Fischer K; Brettle J; Poschmann A
    Beitr Infusionsther; 1990; 26():374-6. PubMed ID: 1703876
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Increasing patient safety in veterinary transfusion medicine: an overview of pretransfusion testing.
    Tocci LJ; Ewing PJ
    J Vet Emerg Crit Care (San Antonio); 2009 Feb; 19(1):66-73. PubMed ID: 19691586
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pretransfusion testing practices in North America, 2005-2010: an analysis of the College Of American Pathologists Interlaboratory Comparison Program J-survey data, 2005-2010.
    Downes KA; Shulman IA
    Arch Pathol Lab Med; 2012 Mar; 136(3):294-300. PubMed ID: 22372905
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Gel agglutination test--a new test system for semiquantitative detection of feto-maternal transfusion in Rhesus incompatibility].
    David M; Stelzer A; Wittmann G; Dudenhausen JW; Salama A
    Z Geburtshilfe Neonatol; 1999; 203(6):241-5. PubMed ID: 10612196
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Single-center comparison of gel microcolumn and solid-phase methods for antibody screening.
    Schmidt A; Bendix BJ; Eapen EK; Bryant SC; Stubbs JR
    Immunohematology; 2013; 29(3):101-4. PubMed ID: 24325170
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Incomplete pretransfusion testing leads to surgical delays.
    McWilliams B; Yazer MH; Cramer J; Triulzi DJ; Waters JH
    Transfusion; 2012 Oct; 52(10):2139-44; quiz 2145. PubMed ID: 22348700
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Antibody of undetermined specificity: frequency, laboratory features, and natural history.
    Liu C; Grossman BJ
    Transfusion; 2013 May; 53(5):931-8. PubMed ID: 23305295
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Conventional tube agglutination with polyethylene glycol versus Red Cell Affinity Column Technology (ReACT): a comparison of antibody detection methods.
    Brumit MC; Stubbs JR
    Ann Clin Lab Sci; 2002; 32(2):155-8. PubMed ID: 12017197
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The relative utility of the autologous control and the antiglobulin test phase of the crossmatch.
    Perkins JT; Arruza M; Fong K; Sosler SD; Saporito C
    Transfusion; 1990; 30(6):503-7. PubMed ID: 2378021
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.