BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 2125884)

  • 1. [Studies on the low skin impedance points and the feature of its distribution along the channels by microcomputer. I. Observation on the reliability of the measurement].
    Hu X; Wu B; Xu J; Hao J
    Zhen Ci Yan Jiu; 1990; 15(3):232-8. PubMed ID: 2125884
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Studies on the low skin impedance points and the feature of its distribution along the channels by microcomputer. II. Distribution of LSIPS along the channels].
    Hu X; Wu B; Xu J; Huang X; Hau J
    Zhen Ci Yan Jiu; 1993; 18(2):163-7. PubMed ID: 8070047
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computerized plotting of low skin impedance points.
    Hu X; Wu B; Huang X; Xu J
    J Tradit Chin Med; 1992 Dec; 12(4):277-82. PubMed ID: 1291821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Effect of increase and decrease of measurement voltage on skin impedance].
    Wu B; Hu X; Xu J
    Zhen Ci Yan Jiu; 1993; 18(2):104-7. PubMed ID: 8070036
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Observation on the distribution of LSIPs along three yang meridians as well as ren and du meridians].
    Huang X; Xu J; Wu B; Hu X
    Zhen Ci Yan Jiu; 1993; 18(2):98-103. PubMed ID: 8070051
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Distribution of low skin impedance points along meridians over the medial side of forearm].
    Hu X; Huang X; Xu J; Wu B
    Zhen Ci Yan Jiu; 1993; 18(2):94-7. PubMed ID: 8070050
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of multifrequency impedance of biologic active points using a dry electrode system.
    Kim MS; Cho YC; Seo ST; Son CS; Kim YN
    J Altern Complement Med; 2012 Sep; 18(9):864-9. PubMed ID: 22913285
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Newly explored electrical properties of normal skin and special skin sites.
    Mayer-Gindner A; Lek-Uthai A; Abdallah O; Bolz A
    Biomed Tech (Berl); 2004 May; 49(5):117-24. PubMed ID: 15212196
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method.
    Rezaei S; Khorsand A; Jamali J
    Acupunct Med; 2012 Jun; 30(2):127-31. PubMed ID: 22467248
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A new sensor technique for measurements of electrical potential profiles of human skin at acupuncture points].
    Wiegele B; Schober G; Kuder J; Kolb FP; Irnich D
    Forsch Komplementmed; 2006 Aug; 13(4):227-32. PubMed ID: 16980770
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of subcutaneous impedance by four-electrode method at acupoints located with single-power alternative current.
    Zhang WB; Jeong DM; Lee YH; Lee MS
    Am J Chin Med; 2004; 32(5):779-88. PubMed ID: 15633812
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrical skin impedance at acupuncture points.
    Pearson S; Colbert AP; McNames J; Baumgartner M; Hammerschlag R
    J Altern Complement Med; 2007 May; 13(4):409-18. PubMed ID: 17532733
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method of local skin perfusion detection.
    Hálek J
    J Med Syst; 2000 Aug; 24(4):257-64. PubMed ID: 11057404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement and analysis of skin electrical impedance.
    Yamamoto Y
    Acta Derm Venereol Suppl (Stockh); 1994; 185():34-8. PubMed ID: 8091925
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new bioimpedance research device (BIRD) for measuring the electrical impedance of acupuncture meridians.
    Wong FW; Lim CE; Smith W
    J Altern Complement Med; 2010 Mar; 16(3):257-64. PubMed ID: 20192910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Frequency dependence of impedances at the acupuncture point Quze (PC3).
    Johng HM; Cho JH; Shin HS; Soh KS; Koo TH; Choi SY; Koo HS; Park MS
    IEEE Eng Med Biol Mag; 2002; 21(2):33-6. PubMed ID: 12012602
    [No Abstract]   [Full Text] [Related]  

  • 17. Rapid assessment of electrode characteristics for impedance imaging.
    Newell JC; Isaacson D; Gisser DG
    IEEE Trans Biomed Eng; 1990 Jul; 37(7):735-8. PubMed ID: 2394462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The mosaic electrical characteristics of the skin.
    Panescu D; Cohen KP; Webster JG; Stratbucker RA
    IEEE Trans Biomed Eng; 1993 May; 40(5):434-9. PubMed ID: 8225332
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Skin impedance measurements using simple and compound electrodes.
    Woo EJ; Hua P; Webster JG; Tompkins WJ; Pallás-Areny R
    Med Biol Eng Comput; 1992 Jan; 30(1):97-102. PubMed ID: 1640763
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site.
    Grimnes S; Jabbari A; Martinsen ØG; Tronstad C
    Skin Res Technol; 2011 Feb; 17(1):26-34. PubMed ID: 20923453
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.