BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

525 related articles for article (PubMed ID: 21274519)

  • 1. Comparison of different types of stationary phases for the analysis of soy isoflavones by HPLC.
    Manchón N; D'Arrigo M; García-Lafuente A; Guillamón E; Villares A; Martínez JA; Ramos A; Rostagno MA
    Anal Bioanal Chem; 2011 May; 400(5):1251-61. PubMed ID: 21274519
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fast analysis of isoflavones by high-performance liquid chromatography using a column packed with fused-core particles.
    Manchón N; D'Arrigo M; García-Lafuente A; Guillamón E; Villares A; Ramos A; Martínez JA; Rostagno MA
    Talanta; 2010 Oct; 82(5):1986-94. PubMed ID: 20875606
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gel.
    Nováková L; Matysová L; Solichová D; Koupparis MA; Solich P
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Dec; 813(1-2):191-7. PubMed ID: 15556533
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fast analysis of soy isoflavones by high-performance liquid chromatography with monolithic columns.
    Rostagno MA; Palma M; Barroso CG
    Anal Chim Acta; 2007 Jan; 582(2):243-9. PubMed ID: 17386499
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6 mm I.D. silica monolithic columns.
    Gritti F; Guiochon G
    J Chromatogr A; 2012 May; 1238():77-90. PubMed ID: 22503619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.
    Kurdi SE; Muaileq DA; Alhazmi HA; Bratty MA; Deeb SE
    Acta Pharm; 2017 Jun; 67(2):203-213. PubMed ID: 28590909
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of monolithic HPLC columns for various pharmaceutical separations: method transfer from conventional phases and batch to batch repeatability.
    El Deeb S; Preu L; Wätzig H
    J Pharm Biomed Anal; 2007 May; 44(1):85-95. PubMed ID: 17346916
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Practical comparison of 2.7 microm fused-core silica particles and porous sub-2 microm particles for fast separations in pharmaceutical process development.
    Abrahim A; Al-Sayah M; Skrdla P; Bereznitski Y; Chen Y; Wu N
    J Pharm Biomed Anal; 2010 Jan; 51(1):131-7. PubMed ID: 19758782
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.
    Ma Y; Chassy AW; Miyazaki S; Motokawa M; Morisato K; Uzu H; Ohira M; Furuno M; Nakanishi K; Minakuchi H; Mriziq K; Farkas T; Fiehn O; Tanaka N
    J Chromatogr A; 2015 Feb; 1383():47-57. PubMed ID: 25648581
    [TBL] [Abstract][Full Text] [Related]  

  • 10. System maps for retention of neutral organic compounds under isocratic conditions on a reversed-phase monolithic column.
    Chu Y; Poole CF
    J Chromatogr A; 2003 Jun; 1003(1-2):113-21. PubMed ID: 12899300
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of solvent polarity and acidity on the extraction efficiency of isoflavones from soybeans (Glycine max).
    Lin F; Giusti MM
    J Agric Food Chem; 2005 May; 53(10):3795-800. PubMed ID: 15884799
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultra high-performance liquid chromatography of porphyrins in clinical materials: column and mobile phase selection and optimisation.
    Benton CM; Lim CK; Moniz C; Jones DJ
    Biomed Chromatogr; 2012 Jun; 26(6):714-9. PubMed ID: 22031323
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of monolithic columns in pharmaceutical analysis. Determination of indomethacin and its degradation products.
    Záková P; Sklenárová H; Nováková L; Hájková R; Matysová L; Solich P
    J Sep Sci; 2009 Aug; 32(15-16):2786-92. PubMed ID: 19603393
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance Comparison Between Monolithic, Core-Shell, and Totally Porous Particulate Columns for Application in Greener and Faster Chromatography.
    Ibrahim AE; Hashem H; Saleh H; Elhenawee M
    J AOAC Int; 2018 Nov; 101(6):1985-1992. PubMed ID: 29843866
    [No Abstract]   [Full Text] [Related]  

  • 15. Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column.
    Chocholouš P; Kosařová L; Satínský D; Sklenářová H; Solich P
    Talanta; 2011 Aug; 85(2):1129-34. PubMed ID: 21726748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of a Chromolith RP-18e column for the screening of beta-blockers.
    Pous-Torres S; Ruiz-Angel MJ; Torres-Lapasió JR; García-Alvarez-Coque MC
    J Sep Sci; 2009 Aug; 32(15-16):2841-53. PubMed ID: 19606443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.
    Aral T; Aral H; Ziyadanoğulları B; Ziyadanoğulları R
    Talanta; 2015 Jan; 131():64-73. PubMed ID: 25281074
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Adsorption, separation, and purification of cyclosporine A using reversed-phase liquid chromatography].
    Li Z; Fu Q; Dai Z; Jin Y; Liang X
    Se Pu; 2022 Jan; 40(1):66-73. PubMed ID: 34985217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The separation of flavonoids from Pongamia pinnata using combination columns in high-speed counter-current chromatography with a three-phase solvent system.
    Yin H; Zhang S; Long L; Yin H; Tian X; Luo X; Nan H; He S
    J Chromatogr A; 2013 Nov; 1315():80-5. PubMed ID: 24090596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monolithic silica columns for high-efficiency separations by high-performance liquid chromatography.
    Ishizuka N; Kobayashi H; Minakuchi H; Nakanishi K; Hirao K; Hosoya K; Ikegami T; Tanaka N
    J Chromatogr A; 2002 Jun; 960(1-2):85-96. PubMed ID: 12150566
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.