These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Comparison of three-dimensional pseudo-continuous arterial spin labeling perfusion imaging with gradient-echo and spin-echo dynamic susceptibility contrast MRI. Wong AM; Yan FX; Liu HL J Magn Reson Imaging; 2014 Feb; 39(2):427-33. PubMed ID: 23677620 [TBL] [Abstract][Full Text] [Related]
5. Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T. Fernández-Seara MA; Wang Z; Wang J; Rao HY; Guenther M; Feinberg DA; Detre JA Magn Reson Med; 2005 Nov; 54(5):1241-7. PubMed ID: 16193469 [TBL] [Abstract][Full Text] [Related]
6. Arterial spin labeling with simultaneous multi-slice echo planar imaging. Feinberg DA; Beckett A; Chen L Magn Reson Med; 2013 Dec; 70(6):1500-6. PubMed ID: 24130105 [TBL] [Abstract][Full Text] [Related]
7. Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling. Gai ND; Chou YY; Pham D; Butman JA Magn Reson Imaging; 2017 Dec; 44():119-124. PubMed ID: 28867670 [TBL] [Abstract][Full Text] [Related]
8. A novel continuous arterial spin labeling approach for CBF measurement in rats with reduced labeling time and optimized signal-to-noise ratio efficiency. Meng Y; Lei H MAGMA; 2009 Apr; 22(2):135-42. PubMed ID: 19082645 [TBL] [Abstract][Full Text] [Related]
9. Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification. Gallichan D; Jezzard P Magn Reson Med; 2009 Mar; 61(3):686-95. PubMed ID: 19132757 [TBL] [Abstract][Full Text] [Related]
10. Optimization of simultaneous multislice EPI for concurrent functional perfusion and BOLD signal measurements at 7T. Ivanov D; Poser BA; Huber L; Pfeuffer J; Uludağ K Magn Reson Med; 2017 Jul; 78(1):121-129. PubMed ID: 27465273 [TBL] [Abstract][Full Text] [Related]
11. Theoretical and experimental evaluation of multi-band EPI for high-resolution whole brain pCASL Imaging. Li X; Wang D; Auerbach EJ; Moeller S; Ugurbil K; Metzger GJ Neuroimage; 2015 Feb; 106():170-81. PubMed ID: 25462690 [TBL] [Abstract][Full Text] [Related]
12. Intra- and interscanner reliability and reproducibility of 3D whole-brain pseudo-continuous arterial spin-labeling MR perfusion at 3T. Wu B; Lou X; Wu X; Ma L J Magn Reson Imaging; 2014 Feb; 39(2):402-9. PubMed ID: 23723043 [TBL] [Abstract][Full Text] [Related]
14. Three-dimensional whole-brain perfusion quantification using pseudo-continuous arterial spin labeling MRI at multiple post-labeling delays: accounting for both arterial transit time and impulse response function. Qin Q; Huang AJ; Hua J; Desmond JE; Stevens RD; van Zijl PC NMR Biomed; 2014 Feb; 27(2):116-28. PubMed ID: 24307572 [TBL] [Abstract][Full Text] [Related]
15. Effects of systematic partial volume errors on the estimation of gray matter cerebral blood flow with arterial spin labeling MRI. Petr J; Mutsaerts HJMM; De Vita E; Steketee RME; Smits M; Nederveen AJ; Hofheinz F; van den Hoff J; Asllani I MAGMA; 2018 Dec; 31(6):725-734. PubMed ID: 29916058 [TBL] [Abstract][Full Text] [Related]