60 related articles for article (PubMed ID: 21276500)
1. Are intrasac pressure measurements useful after endovascular repair of abdominal aortic aneurysms?
Milner R; De Rango P; Verzini F; Cao P
J Vasc Surg; 2011 Feb; 53(2):534-9. PubMed ID: 21276500
[TBL] [Abstract][Full Text] [Related]
2. Editors' commentary.
Forbes TL; Ricco JB
J Vasc Surg; 2011 Feb; 53(2):539. PubMed ID: 21276501
[No Abstract] [Full Text] [Related]
3. Part one: for the motion. Serial sac pressure measurements can determine which type II endoleaks can be treated.
Milner R
Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):143-5. PubMed ID: 21316020
[No Abstract] [Full Text] [Related]
4. Aortic aneurysm pressure sensors can be of value in the acute postoperative setting.
Gandhi RT; Katzen BT; Tsoukas AI; Geisbüsch P
Vasc Endovascular Surg; 2011 Jul; 45(5):412-7. PubMed ID: 21576207
[TBL] [Abstract][Full Text] [Related]
5. Part two: against the motion. Measuring intra-sac pressure measurements is of no benefit to the patient.
De Rango P; Verzini F; Cao P
Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):145-8. PubMed ID: 21316021
[No Abstract] [Full Text] [Related]
6. First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms.
Ellozy SH; Carroccio A; Lookstein RA; Minor ME; Sheahan CM; Juta J; Cha A; Valenzuela R; Addis MD; Jacobs TS; Teodorescu VJ; Marin ML
J Vasc Surg; 2004 Sep; 40(3):405-12. PubMed ID: 15337865
[TBL] [Abstract][Full Text] [Related]
7. In vitro analysis of type II endoleaks and aneurysm sac pressurization on longitudinal stent-graft displacement.
Knowles M; Pellisar T; Murphy EH; Stanley GA; Hashmi AF; Arko MZ; Arko FR
J Endovasc Ther; 2011 Aug; 18(4):601-6. PubMed ID: 21861753
[TBL] [Abstract][Full Text] [Related]
8. Are intra-sac pressure measurements useful following endovascular repair of abdominal aortic aneurysms?
Forbes TL; Ricco JB
Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):148-9. PubMed ID: 21413169
[No Abstract] [Full Text] [Related]
9. Trans-Atlantic debate: Are intra-sac pressure measurements useful following endovascular repair of abdominal aortic aneurysms?
Ricco JB; Forbes TL
Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):143. PubMed ID: 21413193
[No Abstract] [Full Text] [Related]
10. Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study.
Chaudhuri A; Ansdell LE; Grass AJ; Adiseshiah M
Eur J Vasc Endovasc Surg; 2004 Oct; 28(4):373-8. PubMed ID: 15350558
[TBL] [Abstract][Full Text] [Related]
11. Experience and outcomes after a decade of endovascular abdominal aortic aneurysm repair: a retrospective study from a community-based single center.
Kalteis M; Haller F; Artmann A; Ratzenböck M; Hartl P; Lugmayr H
Ann Vasc Surg; 2012 Apr; 26(3):330-7. PubMed ID: 22285344
[TBL] [Abstract][Full Text] [Related]
12. Treatment of type II endoleaks with a novel polyurethane thrombogenic foam: induction of endoleak thrombosis and elimination of intra-aneurysmal pressure in the canine model.
Rhee JY; Trocciola SM; Dayal R; Lin S; Chaer R; Kumar N; Mousa A; Bernheim J; Christos P; Prince M; Marin ML; Gordon R; Badimon J; Fuster V; Kent KC; Faries PL
J Vasc Surg; 2005 Aug; 42(2):321-8. PubMed ID: 16102634
[TBL] [Abstract][Full Text] [Related]
13. Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair.
Baril DT; Silverberg D; Ellozy SH; Carroccio A; Jacobs TS; Sachdev U; Teodorescu VJ; Lookstein RA; Marin ML
Ann Vasc Surg; 2008 Jan; 22(1):30-6. PubMed ID: 18083340
[TBL] [Abstract][Full Text] [Related]
14. A novel treatment approach to a type II endoleak at endograft implantation using components of an endosensor monitoring device.
Louwers LM; Seder CW; Bove PG
Vasc Endovascular Surg; 2010 Oct; 44(7):568-71. PubMed ID: 20675313
[TBL] [Abstract][Full Text] [Related]
15. Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: correlation with chronic sac pressure measurement.
Ellozy SH; Carroccio A; Lookstein RA; Jacobs TS; Addis MD; Teodorescu VJ; Marin ML
J Vasc Surg; 2006 Jan; 43(1):2-7. PubMed ID: 16414379
[TBL] [Abstract][Full Text] [Related]
16. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms.
Baum RA; Carpenter JP; Cope C; Golden MA; Velazquez OC; Neschis DG; Mitchell ME; Barker CF; Fairman RM
J Vasc Surg; 2001 Jan; 33(1):32-41. PubMed ID: 11137921
[TBL] [Abstract][Full Text] [Related]
17. Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular repair of abdominal aortic aneurysms.
Velazquez OC; Baum RA; Carpenter JP; Golden MA; Cohn M; Pyeron A; Barker CF; Criado FJ; Fairman RM
J Vasc Surg; 2000 Oct; 32(4):777-88. PubMed ID: 11013042
[TBL] [Abstract][Full Text] [Related]
18. Endovascular repair of abdominal aortic aneurysms: device-specific outcome.
Ouriel K; Clair DG; Greenberg RK; Lyden SP; O'Hara PJ; Sarac TP; Srivastava SD; Butler B; Sampram ES
J Vasc Surg; 2003 May; 37(5):991-8. PubMed ID: 12756344
[TBL] [Abstract][Full Text] [Related]
19. Annual rupture risk of abdominal aortic aneurysm enlargement without detectable endoleak after endovascular abdominal aortic repair.
Koole D; Moll FL; Buth J; Hobo R; Zandvoort HJ; Bots ML; Pasterkamp G; van Herwaarden JA;
J Vasc Surg; 2011 Dec; 54(6):1614-22. PubMed ID: 21917405
[TBL] [Abstract][Full Text] [Related]
20. Long-term outcomes of secondary procedures after endovascular aneurysm repair.
Mehta M; Sternbach Y; Taggert JB; Kreienberg PB; Roddy SP; Paty PS; Ozsvath KJ; Darling RC
J Vasc Surg; 2010 Dec; 52(6):1442-9. PubMed ID: 20724099
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]