170 related articles for article (PubMed ID: 21285480)
1. A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.
Asuni G; Jensen JM; McCurdy BM
Phys Med Biol; 2011 Feb; 56(4):1207-23. PubMed ID: 21285480
[TBL] [Abstract][Full Text] [Related]
2. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
[TBL] [Abstract][Full Text] [Related]
3. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
[TBL] [Abstract][Full Text] [Related]
4. Monte Carlo simulation of small electron fields collimated by the integrated photon MLC.
Mihaljevic J; Soukup M; Dohm O; Alber M
Phys Med Biol; 2011 Feb; 56(3):829-43. PubMed ID: 21242628
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo commissioning of clinical electron beams using large field measurements.
O'Shea TP; Sawkey DL; Foley MJ; Faddegon BA
Phys Med Biol; 2010 Jul; 55(14):4083-105. PubMed ID: 20601775
[TBL] [Abstract][Full Text] [Related]
6. Validation of calculations for electrons modulated with conventional photon multileaf collimators.
Klein EE; Vicic M; Ma CM; Low DA; Drzymala RE
Phys Med Biol; 2008 Mar; 53(5):1183-208. PubMed ID: 18296757
[TBL] [Abstract][Full Text] [Related]
7. The influence of a novel transmission detector on 6 MV x-ray beam characteristics.
Venkataraman S; Malkoske KE; Jensen M; Nakonechny KD; Asuni G; McCurdy BM
Phys Med Biol; 2009 May; 54(10):3173-83. PubMed ID: 19420428
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo modeling of the ModuLeaf miniature MLC for small field dosimetry and quality assurance of the clinical treatment planning system.
Crop F; Reynaert N; Pittomvils G; Paelinck L; De Gersem W; De Wagter C; Vakaet L; De Neve W; Thierens H
Phys Med Biol; 2007 Jun; 52(11):3275-90. PubMed ID: 17505102
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements.
Edimo P; Clermont C; Kwato MG; Vynckier S
Phys Med; 2009 Sep; 25(3):111-21. PubMed ID: 18722148
[TBL] [Abstract][Full Text] [Related]
10. Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation.
Chow JC; Grigorov GN
Phys Med Biol; 2007 Jul; 52(13):3965-77. PubMed ID: 17664588
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo dose calculation improvements for low energy electron beams using eMC.
Fix MK; Frei D; Volken W; Neuenschwander H; Born EJ; Manser P
Phys Med Biol; 2010 Aug; 55(16):4577-88. PubMed ID: 20668339
[TBL] [Abstract][Full Text] [Related]
12. Theoretical and experimental validation of treatment planning for narrow MLC defined photon fields.
Lydon JM
Phys Med Biol; 2005 Jun; 50(11):2701-14. PubMed ID: 15901964
[TBL] [Abstract][Full Text] [Related]
13. Linac-based isocentric electron-photon treatment of radically operated breast carcinoma with enhanced dose uniformity in the field gap area.
Tenhunen M; Nyman H; Strengell S; Vaalavirta L
Radiother Oncol; 2009 Oct; 93(1):80-6. PubMed ID: 19433339
[TBL] [Abstract][Full Text] [Related]
14. Electron contamination in 8 and 18 MV photon beams.
Zhu TC; Palta JR
Med Phys; 1998 Jan; 25(1):12-9. PubMed ID: 9472821
[TBL] [Abstract][Full Text] [Related]
15. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
16. Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.
Chen Z; Agostinelli AG; Wilson LD; Nath R
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):872-85. PubMed ID: 15183491
[TBL] [Abstract][Full Text] [Related]
17. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
18. Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images.
Jarry G; Verhaegen F
Phys Med Biol; 2007 Apr; 52(8):2277-99. PubMed ID: 17404469
[TBL] [Abstract][Full Text] [Related]
19. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems.
Paelinck L; Reynaert N; Thierens H; De Neve W; De Wagter C
Phys Med Biol; 2005 May; 50(9):2055-69. PubMed ID: 15843736
[TBL] [Abstract][Full Text] [Related]
20. Absolute dose calculations for Monte Carlo simulations of radiotherapy beams.
Popescu IA; Shaw CP; Zavgorodni SF; Beckham WA
Phys Med Biol; 2005 Jul; 50(14):3375-92. PubMed ID: 16177516
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]