246 related articles for article (PubMed ID: 21287738)
1. [STR profiling of genomic DNA from HE stained tissue sections].
Liu Y; Zhao ZM; Li L; Deng KF
Fa Yi Xue Za Zhi; 2010 Oct; 26(5):349-52. PubMed ID: 21287738
[TBL] [Abstract][Full Text] [Related]
2. [STR genotyping in unbuffered formalin fixed paraffin embedded tissue].
Liu Y; Li L; Zhao ZM; Zhang SH; Zhao SM
Fa Yi Xue Za Zhi; 2009 Oct; 25(5):337-40, 344. PubMed ID: 20000040
[TBL] [Abstract][Full Text] [Related]
3. [Forensic analysis of LCN DNA using sample concentration methods followed by miniSTR genotyping].
Gu LH; Dong Y; Zhang C; Xu Y; Chen RH; Hu W; Chen LK; Zhou HG
Fa Yi Xue Za Zhi; 2010 Oct; 26(5):361-3. PubMed ID: 21287741
[TBL] [Abstract][Full Text] [Related]
4. [Forensic application of expressmarker 22 STR loci direct PCR amplification kit].
Zou KN; Cao Y; Xia ZF; Zheng WG; Zhou HG
Fa Yi Xue Za Zhi; 2012 Dec; 28(6):448-50. PubMed ID: 23484329
[TBL] [Abstract][Full Text] [Related]
5. Multiplex STR typing of aortic tissues from unidentified cadavers.
Sato Y; Motani H; Inoue H; Hayakawa M; Yajima D; Nagasawa S; Kobayashi K; Sato K; Otsuka K; Iwase H
Leg Med (Tokyo); 2009 Apr; 11 Suppl 1():S455-7. PubMed ID: 19362507
[TBL] [Abstract][Full Text] [Related]
6. Efficiency evaluation of a DNA extraction and purification protocol on archival formalin-fixed and paraffin-embedded tissue.
Farrugia A; Keyser C; Ludes B
Forensic Sci Int; 2010 Jan; 194(1-3):e25-8. PubMed ID: 19781880
[TBL] [Abstract][Full Text] [Related]
7. [Application of MiniFiler kit in forensic DNA testing of low copy number template].
Tang JP; Wu D; Zhang C; Zhou HG
Fa Yi Xue Za Zhi; 2007 Aug; 23(4):304-6. PubMed ID: 17896528
[TBL] [Abstract][Full Text] [Related]
8. [Developing of a new multicolor-fluorescent labeled STR amplification kit].
Li L; Chen GH; Li CT; Liu Y; Lin Y; Que TZ; Zhao ZM; Wang YX
Fa Yi Xue Za Zhi; 2006 Apr; 22(2):111-6. PubMed ID: 16850595
[TBL] [Abstract][Full Text] [Related]
9. AmpFlSTR Profiler Plus and AmpFlSTR COfiler analysis of tissues stored in GenoFix, a new tissue preservation solution for mass disaster DNA identification.
Frégeau CJ; Vanstone H; Borys S; McLean D; Maroun JA; Birnboin HC; Fourney RM
J Forensic Sci; 2001 Sep; 46(5):1180-90. PubMed ID: 11569563
[TBL] [Abstract][Full Text] [Related]
10. Analysis of human fecal material for autosomal and Y chromosome STRs.
Roy R
J Forensic Sci; 2003 Sep; 48(5):1035-40. PubMed ID: 14535665
[TBL] [Abstract][Full Text] [Related]
11. [Effect of urinary trypsin inhibitor on DNA genotyping in urine samples].
Zhang SH; Zhao SM; Li CT
Fa Yi Xue Za Zhi; 2010 Dec; 26(6):443-5, 448. PubMed ID: 21425608
[TBL] [Abstract][Full Text] [Related]
12. Typeability of PowerPlex Y (Promega) profiles in selected tissue samples incubated in various environments.
Niemcunowicz-Janica A; Pepiński W; Janica JR; Janica J; Skawrońska M; Koc-Zórawska E
Arch Med Sadowej Kryminol; 2007; 57(4):385-8. PubMed ID: 18432137
[TBL] [Abstract][Full Text] [Related]
13. Automated forensic DNA purification optimized for FTA card punches and identifiler STR-based PCR analysis.
Tack LC; Thomas M; Reich K
Clin Lab Med; 2007 Mar; 27(1):183-91. PubMed ID: 17416311
[TBL] [Abstract][Full Text] [Related]
14. [Determination of polymorphic DNA sequences STR-PCR in decomposed human tissues].
Piasecka-Pazik D; Szczerkowska Z
Arch Med Sadowej Kryminol; 2003; 53(3):209-14. PubMed ID: 14669717
[TBL] [Abstract][Full Text] [Related]
15. [The evaluation of Identifiler system in paternity testing].
Que TZ; Yan PH; Lin Y; Liu Y; Li L
Fa Yi Xue Za Zhi; 2009 Jun; 25(3):184-6. PubMed ID: 19697775
[TBL] [Abstract][Full Text] [Related]
16. Development of STR profiles from firearms and fired cartridge cases.
Horsman-Hall KM; Orihuela Y; Karczynski SL; Davis AL; Ban JD; Greenspoon SA
Forensic Sci Int Genet; 2009 Sep; 3(4):242-50. PubMed ID: 19647709
[TBL] [Abstract][Full Text] [Related]
17. STR profiles from DNA samples with "undetected" or low quantifiler results.
Cupples CM; Champagne JR; Lewis KE; Cruz TD
J Forensic Sci; 2009 Jan; 54(1):103-7. PubMed ID: 19018932
[TBL] [Abstract][Full Text] [Related]
18. A quadruplex real-time qPCR assay for the simultaneous assessment of total human DNA, human male DNA, DNA degradation and the presence of PCR inhibitors in forensic samples: a diagnostic tool for STR typing.
Hudlow WR; Chong MD; Swango KL; Timken MD; Buoncristiani MR
Forensic Sci Int Genet; 2008 Mar; 2(2):108-25. PubMed ID: 19083806
[TBL] [Abstract][Full Text] [Related]
19. Concordance study between the AmpFlSTR MiniFiler PCR amplification kit and conventional STR typing kits.
Hill CR; Kline MC; Mulero JJ; Lagacé RE; Chang CW; Hennessy LK; Butler JM
J Forensic Sci; 2007 Jul; 52(4):870-3. PubMed ID: 17553078
[TBL] [Abstract][Full Text] [Related]
20. Validation of a 16-locus fluorescent multiplex system.
Krenke BE; Tereba A; Anderson SJ; Buel E; Culhane S; Finis CJ; Tomsey CS; Zachetti JM; Masibay A; Rabbach DR; Amiott EA; Sprecher CJ
J Forensic Sci; 2002 Jul; 47(4):773-85. PubMed ID: 12136984
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]