These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
204 related articles for article (PubMed ID: 21292380)
1. Comparison of non-calibrated pulse-contour analysis with continuous thermodilution for cardiac output assessment in patients with induced hypothermia after cardiac arrest. Haenggi M; Barthelmes D; Ulmer H; Takala J; Jakob SM Resuscitation; 2011 Apr; 82(4):423-6. PubMed ID: 21292380 [TBL] [Abstract][Full Text] [Related]
2. Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients. Gödje O; Friedl R; Hannekum A Med Sci Monit; 2001; 7(6):1344-50. PubMed ID: 11687755 [TBL] [Abstract][Full Text] [Related]
3. Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients. Sander M; von Heymann C; Foer A; von Dossow V; Grosse J; Dushe S; Konertz WF; Spies CD Crit Care; 2005; 9(6):R729-34. PubMed ID: 16356221 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Missant C; Rex S; Wouters PF Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125 [TBL] [Abstract][Full Text] [Related]
5. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Bogert LW; Wesseling KH; Schraa O; Van Lieshout EJ; de Mol BA; van Goudoever J; Westerhof BE; van Lieshout JJ Anaesthesia; 2010 Nov; 65(11):1119-25. PubMed ID: 20860647 [TBL] [Abstract][Full Text] [Related]
6. Non-invasive continuous cerebral temperature monitoring in patients treated with mild therapeutic hypothermia: an observational pilot study. Zeiner A; Klewer J; Sterz F; Haugk M; Krizanac D; Testori C; Losert H; Ayati S; Holzer M Resuscitation; 2010 Jul; 81(7):861-6. PubMed ID: 20398992 [TBL] [Abstract][Full Text] [Related]
8. Accuracy of continuous thermodilution cardiac output monitoring by pulmonary artery catheter during therapeutic hypothermia in post-cardiac arrest patients. Ameloot K; Meex I; Genbrugge C; Jans F; Malbrain M; Mullens W; Dens J; De Deyne C; Dupont M Resuscitation; 2014 Sep; 85(9):1263-8. PubMed ID: 25008135 [TBL] [Abstract][Full Text] [Related]
9. A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Cecconi M; Dawson D; Casaretti R; Grounds RM; Rhodes A Minerva Anestesiol; 2010 Dec; 76(12):1010-7. PubMed ID: 20634793 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage. Mutoh T; Ishikawa T; Nishino K; Yasui N J Neurosurg Anesthesiol; 2009 Jul; 21(3):218-25. PubMed ID: 19542999 [TBL] [Abstract][Full Text] [Related]
11. Comparison of arterial pressure cardiac output monitoring with transpulmonary thermodilution in septic patients. Böettger SF; Pavlovic D; Gründling M; Wendt M; Hung O; Henzler D; Kern HR; Lehmann C Med Sci Monit; 2010 Mar; 16(3):PR1-7. PubMed ID: 20190696 [TBL] [Abstract][Full Text] [Related]
12. Unreliability of pulse contour-derived cardiac output in piglets simulating acute hemorrhagic shock and rapid volume expansion. Lee CH; Wang JY; Huang KL; Chiu HW; Fei TC; Chen TS; Chang H J Trauma; 2010 Jun; 68(6):1357-61. PubMed ID: 20539180 [TBL] [Abstract][Full Text] [Related]
13. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. Lorsomradee S; Lorsomradee S; Cromheecke S; De Hert SG J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266 [TBL] [Abstract][Full Text] [Related]
14. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients. Scully CG; Gomatam S; Forrest S; Strauss DG J Clin Monit Comput; 2016 Oct; 30(5):577-86. PubMed ID: 26285740 [TBL] [Abstract][Full Text] [Related]
16. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Hamzaoui O; Monnet X; Richard C; Osman D; Chemla D; Teboul JL Crit Care Med; 2008 Feb; 36(2):434-40. PubMed ID: 18091547 [TBL] [Abstract][Full Text] [Related]
17. Monitoring of cardiac output by pulse contour method. Thomas B Acta Anaesthesiol Belg; 1978; 29(3):259-70. PubMed ID: 751431 [TBL] [Abstract][Full Text] [Related]
18. Validation of a new arterial pulse contour-based cardiac output device. de Waal EE; Kalkman CJ; Rex S; Buhre WF Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493 [TBL] [Abstract][Full Text] [Related]
19. Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology. Breukers RB; Jansen JR Acta Anaesthesiol Scand; 2004 May; 48(5):658-61. PubMed ID: 15101866 [TBL] [Abstract][Full Text] [Related]
20. Reproducibility of transpulmonary thermodilution measurements in patients with burn shock and hypothermia. Holm C; Mayr M; Hörbrand F; Tegeler J; Henckel von Donnersmarck G; Mühlbauer W; Pfeiffer UJ J Burn Care Rehabil; 2005; 26(3):260-5. PubMed ID: 15879748 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]