137 related articles for article (PubMed ID: 2129447)
1. Kinetic modelling and continuous on-line blood volume measurement during dialysis therapy.
Mann H; Stiller S; Gladziwa U; Königs F
Nephrol Dial Transplant; 1990; 5 Suppl 1():144-6. PubMed ID: 2129447
[TBL] [Abstract][Full Text] [Related]
2. Characteristic profiles of circulating blood volume during dialysis therapy.
Stiller S; Thömmes A; Königs F; Schallenberg U; Mann H
ASAIO Trans; 1989; 35(3):530-2. PubMed ID: 2597525
[TBL] [Abstract][Full Text] [Related]
3. Nature and rate of vascular refilling during hemodialysis and ultrafiltration.
Schneditz D; Roob J; Oswald M; Pogglitsch H; Moser M; Kenner T; Binswanger U
Kidney Int; 1992 Dec; 42(6):1425-33. PubMed ID: 1474776
[TBL] [Abstract][Full Text] [Related]
4. Changes in blood volume during dialysis are dependent upon the rate and amount of ultrafiltrate.
Mann H; Ernst E; Gladziwa U; Schallenberg U; Stiller S
ASAIO Trans; 1989; 35(3):250-2. PubMed ID: 2597456
[TBL] [Abstract][Full Text] [Related]
5. Measurement of relative blood volume changes during haemodialysis: merits and limitations.
Dasselaar JJ; Huisman RM; de Jong PE; Franssen CF
Nephrol Dial Transplant; 2005 Oct; 20(10):2043-9. PubMed ID: 16105867
[No Abstract] [Full Text] [Related]
6. A new method of continuous haemoglobinometric measurement of blood volume during haemodialysis.
Schallenberg U; Stiller S; Mann H
Life Support Syst; 1987; 5(4):293-305. PubMed ID: 3431150
[TBL] [Abstract][Full Text] [Related]
7. Computerised monitoring of sodium and fluid during haemodialysis.
Sturniolo A; Costanzi S; Barbera G; Ruffini MP; Passalacqua S; Fulignati P; Splendiani G
Nephrol Dial Transplant; 1990; 5 Suppl 1():162-4. PubMed ID: 2129452
[TBL] [Abstract][Full Text] [Related]
8. L-carnitine improves vascular refilling in haemodialysis patients during ultrafiltration.
Záruba J; Probst W; Binswanger U
Nephrol Dial Transplant; 1994; 9(5):587-8. PubMed ID: 8090349
[No Abstract] [Full Text] [Related]
9. Determination of fluid shifts during chronic hemodialysis using bioimpedance spectroscopy and an in-line hematocrit monitor.
Jabara AE; Mehta RL
ASAIO J; 1995; 41(3):M682-7. PubMed ID: 8573892
[TBL] [Abstract][Full Text] [Related]
10. Haemodialysis with on-line monitoring equipment: tools or toys?
Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
[TBL] [Abstract][Full Text] [Related]
11. Interstitial correction of blood volume decrease during hemodialysis.
Kouw PM; De Vries PM; Oe PL
Int J Artif Organs; 1989 Oct; 12(10):626-31. PubMed ID: 2807587
[TBL] [Abstract][Full Text] [Related]
12. Time to Reconsider the Role of Relative Blood Volume Monitoring for Fluid Management in Hemodialysis.
Keane DF; Baxter P; Lindley E; Rhodes L; Pavitt S
ASAIO J; 2018; 64(6):812-818. PubMed ID: 29677039
[TBL] [Abstract][Full Text] [Related]
13. [Continuous measurement of blood volume changes in hemodialysis using an ultrasound method].
Roob JM; Schneditz D; Haas GM; Horina JH; Pogglitsch H
Wien Klin Wochenschr; 1990 Mar; 102(5):131-6. PubMed ID: 2181783
[TBL] [Abstract][Full Text] [Related]
14. Assessing the blood volume and heart rate responses during haemodialysis in fluid overloaded patients using support vector regression.
Javed F; Savkin AV; Chan GS; Middleton PM; Malouf P; Steel E; Mackie J; Lovell NH
Physiol Meas; 2009 Nov; 30(11):1251-66. PubMed ID: 19812455
[TBL] [Abstract][Full Text] [Related]
15. Body fluid dynamics during dialysis and in dialysis hypotension.
Koomans HA
Contrib Nephrol; 1996; 119():173-81. PubMed ID: 8783611
[No Abstract] [Full Text] [Related]
16. Short time dialysis with continuous blood volume control.
Stiller S; Schallenberg U; Gladziwa U; Ernst E; Mann H
Int J Artif Organs; 1990 Feb; 13(2):83-6. PubMed ID: 2347660
[TBL] [Abstract][Full Text] [Related]
17. Dialysis schedule-related fluid state and cardiovascular effects.
Wizemann V; Timio M
Nephrol Dial Transplant; 1998; 13 Suppl 6():91-3. PubMed ID: 9719212
[No Abstract] [Full Text] [Related]
18. A physiologically based model of vascular refilling during ultrafiltration in hemodialysis.
de los Reyes V AA; Fuertinger DH; Kappel F; Meyring-Wösten A; Thijssen S; Kotanko P
J Theor Biol; 2016 Feb; 390():146-55. PubMed ID: 26643943
[TBL] [Abstract][Full Text] [Related]
19. Blood volume modeling and refilling rate estimation in hemodialysis by continuous hemoglobin monitoring.
Arrigo G; Bucci R; Colasanti G; Rustici A; Sivo M; Rizza V; D'Amico G
Int J Artif Organs; 1995 Sep; 18(9):509-12. PubMed ID: 8582767
[TBL] [Abstract][Full Text] [Related]
20. Change in inferior vena caval diameter detected by ultrasonography during and after hemodialysis.
Tetsuka T; Ando Y; Ono S; Asano Y
ASAIO J; 1995; 41(1):105-10. PubMed ID: 7727811
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]