445 related articles for article (PubMed ID: 21301136)
1. Physiological assessment of myocardial perfusion using nuclear cardiology would enhance coronary artery disease patient care: which imaging modality is best for evaluation of myocardial ischemia? (SPECT-side).
Yoshinaga K; Manabe O; Tamaki N
Circ J; 2011; 75(3):713-22; discussion 731. PubMed ID: 21301136
[TBL] [Abstract][Full Text] [Related]
2. Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease.
George RT; Arbab-Zadeh A; Miller JM; Vavere AL; Bengel FM; Lardo AC; Lima JA
Circ Cardiovasc Imaging; 2012 May; 5(3):333-40. PubMed ID: 22447807
[TBL] [Abstract][Full Text] [Related]
3. Serial myocardial perfusion imaging: defining a significant change and targeting management decisions.
Iskandrian AE; Hage FG; Shaw LJ; Mahmarian JJ; Berman DS
JACC Cardiovasc Imaging; 2014 Jan; 7(1):79-96. PubMed ID: 24433711
[TBL] [Abstract][Full Text] [Related]
4. [Progress in nuclear cardiology: new imaging beyond perfusion and function].
Tamaki N
Nihon Igaku Hoshasen Gakkai Zasshi; 1999 Oct; 59(12):656-62. PubMed ID: 10565167
[TBL] [Abstract][Full Text] [Related]
5. Prognostic impact of reducing myocardial ischemia identified using ECG-gated myocardial perfusion SPECT in Japanese patients with coronary artery disease: J-ACCESS 4 study.
Nanasato M; Matsumoto N; Nakajima K; Chikamori T; Moroi M; Takehana K; Momose M; Nishina H; Kasai T; Yoda S; Kiso K; Yamamoto H; Nishimura S; Yamashina A; Kusuoka H; Hirayama A; Nishimura T
Int J Cardiol; 2018 Sep; 267():202-207. PubMed ID: 29859707
[TBL] [Abstract][Full Text] [Related]
6. Myocardial flow reserve derived by dynamic perfusion single-photon emission computed tomography reflects the severity of coronary atherosclerosis.
Iguchi N; Utanohara Y; Suzuki Y; Suzuki M; Hagiya K; Higuchi R; Takamisawa I; Tobaru T; Sumiyoshi T; Isobe M
Int J Cardiovasc Imaging; 2018 Sep; 34(9):1493-1501. PubMed ID: 29679191
[TBL] [Abstract][Full Text] [Related]
7. Multicentre multi-device hybrid imaging study of coronary artery disease: results from the EValuation of INtegrated Cardiac Imaging for the Detection and Characterization of Ischaemic Heart Disease (EVINCI) hybrid imaging population.
Liga R; Vontobel J; Rovai D; Marinelli M; Caselli C; Pietila M; Teresinska A; Aguadé-Bruix S; Pizzi MN; Todiere G; Gimelli A; Chiappino D; Marraccini P; Schroeder S; Drosch T; Poddighe R; Casolo G; Anagnostopoulos C; Pugliese F; Rouzet F; Le Guludec D; Cappelli F; Valente S; Gensini GF; Zawaideh C; Capitanio S; Sambuceti G; Marsico F; Filardi PP; Fernández-Golfín C; Rincón LM; Graner FP; de Graaf MA; Stehli J; Reyes E; Nkomo S; Mäki M; Lorenzoni V; Turchetti G; Carpeggiani C; Puzzuoli S; Mangione M; Marcheschi P; Giannessi D; Nekolla S; Lombardi M; Sicari R; Scholte AJ; Zamorano JL; Underwood SR; Knuuti J; Kaufmann PA; Neglia D; Gaemperli O;
Eur Heart J Cardiovasc Imaging; 2016 Sep; 17(9):951-60. PubMed ID: 26992419
[TBL] [Abstract][Full Text] [Related]
8. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging.
Doukky R; Hayes K; Frogge N; Balakrishnan G; Dontaraju VS; Rangel MO; Golzar Y; Garcia-Sayan E; Hendel RC
Circulation; 2013 Oct; 128(15):1634-43. PubMed ID: 24021779
[TBL] [Abstract][Full Text] [Related]
9. Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease-state-of-the-evidence and clinical recommendations.
Taqueti VR; Dorbala S; Wolinsky D; Abbott B; Heller GV; Bateman TM; Mieres JH; Phillips LM; Wenger NK; Shaw LJ
J Nucl Cardiol; 2017 Aug; 24(4):1402-1426. PubMed ID: 28585034
[TBL] [Abstract][Full Text] [Related]
10. Technetium-99m-labelled HL91 and technetium-99m-labelled MIBI SPECT imaging for the detection of ischaemic viable myocardium: a preliminary study.
Liu M; Ma Z; Guo X; Zhu J; Su J
Clin Physiol Funct Imaging; 2012 Jan; 32(1):25-32. PubMed ID: 22152075
[TBL] [Abstract][Full Text] [Related]
11. SPECT Versus PET Myocardial Perfusion Imaging in Patients with Equivocal CT.
Singh V; Di Carli MF
Curr Cardiol Rep; 2020 May; 22(6):43. PubMed ID: 32451746
[TBL] [Abstract][Full Text] [Related]
12. Changes in ischaemia as assessed with single-photon emission computed tomography myocardial perfusion imaging in high-risk patients with diabetes without cardiac symptoms: relation with coronary atherosclerosis on computed tomography coronary angiography.
de Graaf MA; Roos CJ; Mansveld JM; Kharagjitsingh AV; Dibbets-Schneider P; Kroft LJ; Jukema JW; Ficaro EP; Bax JJ; Scholte AJ
Eur Heart J Cardiovasc Imaging; 2015 Aug; 16(8):863-70. PubMed ID: 25680384
[TBL] [Abstract][Full Text] [Related]
13. PET-Based Imaging of Ischemic Heart Disease.
Chen K; Miller EJ; Sadeghi MM
PET Clin; 2019 Apr; 14(2):211-221. PubMed ID: 30826019
[TBL] [Abstract][Full Text] [Related]
14. [Nuclear cardiology: the present functions and future perspectives].
Mei X; Fan C
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Feb; 30(1):191-4, 212. PubMed ID: 23488162
[TBL] [Abstract][Full Text] [Related]
15. Comparative effectiveness of exercise electrocardiography with or without myocardial perfusion single photon emission computed tomography in women with suspected coronary artery disease: results from the What Is the Optimal Method for Ischemia Evaluation in Women (WOMEN) trial.
Shaw LJ; Mieres JH; Hendel RH; Boden WE; Gulati M; Veledar E; Hachamovitch R; Arrighi JA; Merz CN; Gibbons RJ; Wenger NK; Heller GV;
Circulation; 2011 Sep; 124(11):1239-49. PubMed ID: 21844080
[TBL] [Abstract][Full Text] [Related]
16. Effective risk stratification of patients on the basis of myocardial perfusion SPECT is dependent on appropriate patient selection.
Alexander S; Doukky R
Curr Cardiol Rep; 2015 Jan; 17(1):549. PubMed ID: 25418932
[TBL] [Abstract][Full Text] [Related]
17. Yield and diagnostic value of stress myocardial perfusion imaging in patients without known coronary artery disease presenting with syncope.
AlJaroudi WA; Alraies MC; Wazni O; Cerqueira MD; Jaber WA
Circ Cardiovasc Imaging; 2013 May; 6(3):384-91. PubMed ID: 23418293
[TBL] [Abstract][Full Text] [Related]
18. State of the Art in Noninvasive Imaging of Ischemic Heart Disease and Coronary Microvascular Dysfunction in Women: Indications, Performance, and Limitations.
Koilpillai P; Aggarwal NR; Mulvagh SL
Curr Atheroscler Rep; 2020 Oct; 22(12):73. PubMed ID: 33009953
[TBL] [Abstract][Full Text] [Related]
19. Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction.
Clerc OF; Fuchs TA; Possner M; Vontobel J; Mikulicic F; Stehli J; Liga R; Benz DC; Gräni C; Pazhenkottil AP; Gaemperli O; Buechel RR; Kaufmann PA
Eur Heart J Cardiovasc Imaging; 2017 Jan; 18(1):31-38. PubMed ID: 26985074
[TBL] [Abstract][Full Text] [Related]
20. The present role of nuclear cardiology in clinical practice.
Clark AN; Beller GA
Q J Nucl Med Mol Imaging; 2005 Mar; 49(1):43-58. PubMed ID: 15724135
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]