BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

379 related articles for article (PubMed ID: 21302785)

  • 1. Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom.
    Schaeken B; Lelie S; Meijnders P; Van den Weyngaert D; Janssens H; Verellen D
    Med Phys; 2010 Dec; 37(12):6292-9. PubMed ID: 21302785
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetry in translation total body irradiation technique: a computer treatment planning approach and an experimental study concerning lung sparing.
    Zabatis Ch; Koligliatis T; Xenofos S; Pistevou K; Psarakos K; Haritanti A; Beroukas K
    J BUON; 2008; 13(2):253-62. PubMed ID: 18555474
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Total body irradiation-an attachment free sweeping beam technique.
    Härtl PM; Treutwein M; Hautmann MG; März M; Pohl F; Kölbl O; Dobler B
    Radiat Oncol; 2016 Jun; 11():81. PubMed ID: 27287010
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of Dose Calculation for Hemibody Treatments at Extended Distance Using a Commercial Treatment Planning System.
    Batta Y; Juhasz J; Farrell T
    J Med Imaging Radiat Sci; 2019 Jun; 50(2):261-271. PubMed ID: 31176434
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In-vivo dosimetry by diode semiconductors in combination with portal films during TBI: reporting a 5-year clinical experience.
    Mangili P; Fiorino C; Rosso A; Cattaneo GM; Parisi R; Villa E; Calandrino R
    Radiother Oncol; 1999 Sep; 52(3):269-76. PubMed ID: 10580875
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of helical tomotherapy machine using EPR/alanine dosimetry.
    Perichon N; Garcia T; François P; Lourenço V; Lesven C; Bordy JM
    Med Phys; 2011 Mar; 38(3):1168-77. PubMed ID: 21520829
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: II. Clinical electron beams.
    Zeng GG; McEwen MR; Rogers DW; Klassen NV
    Phys Med Biol; 2005 Mar; 50(6):1119-29. PubMed ID: 15798312
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calibration of a mosfet detection system for 6-MV in vivo dosimetry.
    Scalchi P; Francescon P
    Int J Radiat Oncol Biol Phys; 1998 Mar; 40(4):987-93. PubMed ID: 9531385
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.
    Anton M; Wagner D; Selbach HJ; Hackel T; Hermann RM; Hess CF; Vorwerk H
    Phys Med Biol; 2009 May; 54(9):2915-31. PubMed ID: 19384000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aperture modulated, translating bed total body irradiation.
    Hussain A; Villarreal-Barajas JE; Dunscombe P; Brown DW
    Med Phys; 2011 Feb; 38(2):932-41. PubMed ID: 21452729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Midplane dose determination during total body irradiation using in vivo dosimetry.
    Ribas M; Jornet N; Eudaldo T; Carabante D; Duch MA; Ginjaume M; Gómez de Segura G; Sánchez-Doblado F
    Radiother Oncol; 1998 Oct; 49(1):91-8. PubMed ID: 9886703
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of dose painting of lung tumours using alanine/EPR dosimetry.
    Knudtsen IS; Svestad JG; Skaug Sande EP; Rekstad BL; Rødal J; van Elmpt W; Öllers M; Hole EO; Malinen E
    Phys Med Biol; 2016 Mar; 61(6):2243-54. PubMed ID: 26913997
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of the pure alanine in PMMA tube dosimeter applicability for dosimetry of radiotherapy photon beams: a feasibility study.
    Al-Karmi AM; Ayaz AA; Al-Enezi MS; Abdel-Rahman W; Dwaikat N
    Australas Phys Eng Sci Med; 2015 Sep; 38(3):425-34. PubMed ID: 26138456
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Medical reference dosimetry using EPR measurements of alanine: development of an improved method for clinical dose levels.
    Helt-Hansen J; Rosendal F; Kofoed IM; Andersen CE
    Acta Oncol; 2009; 48(2):216-22. PubMed ID: 18759145
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements.
    Bentefour el H; Tang S; Cascio EW; Testa M; Samuel D; Prieels D; Gottschalk B; Lu HM
    Med Phys; 2015 Apr; 42(4):1936-47. PubMed ID: 25832084
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of field-in-field technique for total body irradiation.
    Onal C; Sonmez A; Arslan G; Sonmez S; Efe E; Oymak E
    Int J Radiat Oncol Biol Phys; 2012 Aug; 83(5):1641-8. PubMed ID: 22284688
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A practical EPR dosimetry system for routine use in radiotherapy: uncertainty analysis of lithium formate dosimeters at the therapeutic dose level.
    Höfel S; Stehle M; Zwicker F; Fix MK; Drescher M
    Phys Med Biol; 2021 Feb; 66(4):045005. PubMed ID: 32422627
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Verification of four-dimensional photon dose calculations.
    Vinogradskiy YY; Balter P; Followill DS; Alvarez PE; White RA; Starkschall G
    Med Phys; 2009 Aug; 36(8):3438-47. PubMed ID: 19746777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Acuros
    Öllers MC; Swinnen ACC; Verhaegen F
    Med Phys; 2020 Nov; 47(11):5829-5837. PubMed ID: 32970849
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.