  • 1. Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.
    Facure A; França WF
    Med Phys; 2010 Dec; 37(12):6332-7. PubMed ID: 21302790
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
    Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
    Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prediction of neutron induced radioactivity in the concrete walls of a PET cyclotron vault room with MCNPX.
    Martínez-Serrano JJ; Díez de los Ríos A
    Med Phys; 2010 Nov; 37(11):6015-21. PubMed ID: 21158313
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The refined shielding design for the cyclotron room of the Buddhist Tzu Chi General Hospital.
    Sheu RD; Chen CC; Sheu RJ; Kao CH; Jiang SH
    Radiat Prot Dosimetry; 2005; 115(1-4):216-21. PubMed ID: 16381715
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of the neutron dose field around a biomedical cyclotron: FLUKA simulation and experimental measurements.
    Infantino A; Cicoria G; Lucconi G; Pancaldi D; Vichi S; Zagni F; Mostacci D; Marengo M
    Phys Med; 2016 Dec; 32(12):1602-1608. PubMed ID: 27919623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis and improvement of cyclotron thallium target room shield.
    Hajiloo N; Raisali G; Aslani G
    Radiat Prot Dosimetry; 2008; 130(4):427-33. PubMed ID: 18417490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiation Protection Studies for Medical Particle Accelerators using Fluka Monte Carlo Code.
    Infantino A; Cicoria G; Lucconi G; Pancaldi D; Vichi S; Zagni F; Mostacci D; Marengo M
    Radiat Prot Dosimetry; 2017 Apr; 173(1-3):185-191. PubMed ID: 27886990
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators.
    Martínez-Ovalle SA; Barquero R; Gómez-Ros JM; Lallena AM
    Radiat Prot Dosimetry; 2012 Mar; 148(4):457-64. PubMed ID: 21750004
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo neutron doses estimations inside a PET cyclotron vault room.
    Barquero R; Méndez R; Martí-Climent JM; Quincoces G
    Radiat Prot Dosimetry; 2007; 126(1-4):477-81. PubMed ID: 17504752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. On the tenth value distance of the photon field along the maze of high-energy linear accelerator vaults.
    Han Z; Chin LM
    J Appl Clin Med Phys; 2018 Mar; 19(2):311-316. PubMed ID: 29374424
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shielding implications for secondary neutrons and photons produced within the patient during IMPT.
    DeMarco J; Kupelian P; Santhanam A; Low D
    Med Phys; 2013 Jul; 40(7):071701. PubMed ID: 23822405
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preliminary production of 211At at the Texas A&M University Cyclotron Institute.
    Martin TM; Bhakta V; Al-Harbi A; Hackemack M; Tabacaru G; Tribble R; Shankar S; Akabani G
    Health Phys; 2014 Jul; 107(1):1-9. PubMed ID: 24849899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator.
    Krmar M; Nikolić D; Kuzmanović A; Kuzmanović Z; Ganezer K
    Med Phys; 2013 Aug; 40(8):083902. PubMed ID: 23927362
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Neutron shielding calculations in a proton therapy facility based on Monte Carlo simulations and analytical models: criterion for selecting the method of choice.
    Titt U; Newhauser WD
    Radiat Prot Dosimetry; 2005; 115(1-4):144-8. PubMed ID: 16381702
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Decommissioning of a Medical Cyclotron Vault: The Case Study of the National Cancer Institute of Milano.
    Pola A; Bortot D; Pasquato S; Mazzucconi D; Chiesa C; Zanellati F; Brusa A
    Health Phys; 2024 Aug; 127(2):276-286. PubMed ID: 38394553
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neutron spectra due (13)N production in a PET cyclotron.
    Benavente JA; Vega-Carrillo HR; Lacerda MA; Fonseca TC; Faria FP; da Silva TA
    Appl Radiat Isot; 2015 May; 99():20-4. PubMed ID: 25699664
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Study of the neutron field in the vicinity of an unshielded PET cyclotron.
    Méndez R; Iñiguez MP; Martí-Climent JM; Peñuelas I; Vega-Carrillo HR; Barquero R
    Phys Med Biol; 2005 Nov; 50(21):5141-52. PubMed ID: 16237246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  