These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 21303392)

  • 1. Programming ICDs in the Modern Era beyond Out-of-the Box Settings.
    Mansour F; Khairy P
    Pacing Clin Electrophysiol; 2011 Apr; 34(4):506-20. PubMed ID: 21303392
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ICD monitoring zones: intricacies, pitfalls, and programming tips.
    Mansour F; Khairy P
    J Cardiovasc Electrophysiol; 2008 May; 19(5):568-74. PubMed ID: 18266679
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks.
    Tzeis S; Andrikopoulos G; Kolb C; Vardas PE
    Europace; 2008 Nov; 10(11):1256-65. PubMed ID: 18708639
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?
    Francia P; Balla C; Uccellini A; Cappato R
    J Cardiovasc Electrophysiol; 2009 Sep; 20(9):1077-82. PubMed ID: 19500231
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study.
    Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK;
    J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Expanding the benefits of implantable cardioverter-defibrillator therapy: "is less more"?
    Jackson LR; Daubert JP; Thomas KL
    Prog Cardiovasc Dis; 2012; 54(4):372-8. PubMed ID: 22226007
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inappropriate shock: a failure of SVT discriminators in a dual chamber ICD?
    Al-Ahmad A; Tsiperfal A; Hsia HH; Wang PJ
    Pacing Clin Electrophysiol; 2006 Dec; 29(12):1413-5. PubMed ID: 17201851
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rationale and design of the OPTION study: optimal antitachycardia therapy in ICD patients without pacing indications.
    Kolb C; Tzeis S; Sturmer M; Babuty D; Schwab JO; Mantovani G; Janko S; Aimé E; Ocklenburg R; Sick P
    Pacing Clin Electrophysiol; 2010 Sep; 33(9):1141-8. PubMed ID: 20487351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.
    Mishkin JD; Saxonhouse SJ; Woo GW; Burkart TA; Miles WM; Conti JB; Schofield RS; Sears SF; Aranda JM
    J Am Coll Cardiol; 2009 Nov; 54(22):1993-2000. PubMed ID: 19926003
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implantable cardioverter defibrillator algorithms: status review in terms of computational cost.
    Cebrián A; Millet J; Castells F
    Biomed Tech (Berl); 2007 Feb; 52(1):25-30. PubMed ID: 17313330
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improving contemporary algorithms for implantable cardioverter-defibrillator function.
    Shome S; Li D; Thompson J; McCabe A
    J Electrocardiol; 2010; 43(6):503-8. PubMed ID: 20719333
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implantable cardioverter-defibrillators in patients with hypertrophic cardiomyopathy -- dilemmas and difficulties.
    Przybylski A; Małecka L; Pytkowski M; Chojnowska L; Lewandowski M; Sterliński M; Maciag A; Ruzyłło W; Szwed H
    Kardiol Pol; 2005 Oct; 63(4):391-7; discussion 398. PubMed ID: 16273479
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Therapeutic strategies in inappropriate ICD therapy].
    Klein G; Korte T
    Herz; 2005 Nov; 30(7):619-24. PubMed ID: 16333588
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inappropriate shocks or inappropriate programming? A review of Guidant's reconfirmation algorithm.
    Mansour F; Guash E; Berruezo A; Brugada J; Tolosana JM; Mont L
    Europace; 2009 Aug; 11(8):1120-2. PubMed ID: 19443435
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.
    Klein GJ; Gillberg JM; Tang A; Inbar S; Sharma A; Unterberg-Buchwald C; Dorian P; Moore H; Duru F; Rooney E; Becker D; Schaaf K; Benditt D;
    J Cardiovasc Electrophysiol; 2006 Dec; 17(12):1310-9. PubMed ID: 17096661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia.
    Chen RH; Chen KP; Wang FZ; Hua W; Chen X; Zhang S
    Chin Med J (Engl); 2006 Apr; 119(7):557-63. PubMed ID: 16620696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy.
    Lin G; Nishimura RA; Gersh BJ; Phil D; Ommen SR; Ackerman MJ; Brady PA
    Heart; 2009 May; 95(9):709-14. PubMed ID: 19282314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differences in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients.
    Wilkoff BL; Hess M; Young J; Abraham WT
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1002-9. PubMed ID: 15363071
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-chamber implantable cardioverter defibrillators reduce clinical adverse events related to atrial fibrillation when compared with single-chamber defibrillators: a subanalysis of the DATAS trial.
    Ricci RP; Quesada A; Almendral J; Arribas F; Wolpert C; Adragao P; Zoni-Berisso M; Navarro X; DeSanto T; Grammatico A; Santini M;
    Europace; 2009 May; 11(5):587-93. PubMed ID: 19401341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of cardiac tachyarrhythmias in implantable devices.
    Gillberg J
    J Electrocardiol; 2007; 40(6 Suppl):S123-8. PubMed ID: 17993309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.