These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 21304331)

  • 1. A computed tomography-based localizer to determine the entry site of the ventricular end of a parietal ventriculoperitoneal shunt.
    Sarkar H; Thakar S; Kumar SS; Moorthy RK; Rajshekhar V
    Neurosurgery; 2011 Mar; 68(1 Suppl Operative):162-7; discussion 167. PubMed ID: 21304331
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Approach to Slitlike Ventricles: Parietal-Occipital versus Frontal Burr Catheter Entry Sites.
    Craven CL; Pradini-Santos L; Goel A; Thorne L; Watkins LD; Toma AK
    World Neurosurg; 2020 Mar; 135():e447-e451. PubMed ID: 31843723
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
    Antes S; Tschan CA; Heckelmann M; Salah M; Senger S; Linsler S; Oertel J
    World Neurosurg; 2017 May; 101():11-19. PubMed ID: 28179179
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Wishbone: A Cranial Midline Localizing Device.
    Zanaty M; Banu M; Flouty O; Grady S; Holland MT; Isaacs A; Kung D; Limbrick DD; McKhann G; Nagahama Y; Zipfel GJ; Howard MA
    World Neurosurg; 2019 Aug; 128():600-605.e1. PubMed ID: 31100521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CT-based, fiducial-free frameless stereotaxy for difficult ventriculoperitoneal shunt insertion: experience in 26 consecutive patients.
    Reig AS; Stevenson CB; Tulipan NB
    Stereotact Funct Neurosurg; 2010; 88(2):75-80. PubMed ID: 20068382
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Posterior ventricular catheter burr-hole localizer. Technical note.
    Garell PC; Mirsky R; Noh MD; Loftus CM; Hitchon PW; Grady MS; Dacey RG; Howard MA
    J Neurosurg; 1998 Jul; 89(1):157-60. PubMed ID: 9647190
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volumetric measurements in the detection of reduced ventricular volume in patients with normal-pressure hydrocephalus whose clinical condition improved after ventriculoperitoneal shunt placement.
    Anderson RC; Grant JJ; de la Paz R; Frucht S; Goodman RR
    J Neurosurg; 2002 Jul; 97(1):73-9. PubMed ID: 12134935
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Endoscope-guided placement of the ventriculoperitoneal shunt: technique and applications].
    Sagan LM; Kojder I; Madany L; Gizewska M
    Ann Acad Med Stetin; 2006; 52(3):85-9. PubMed ID: 17385353
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors associated with ventricular catheter movement and inaccurate catheter location: post hoc analysis of the hydrocephalus clinical research network ultrasound-guided shunt placement study.
    Whitehead WE; Riva-Cambrin J; Wellons JC; Kulkarni AV; Browd S; Limbrick D; Rozzelle C; Tamber MS; Simon TD; Shannon CN; Holubkov R; Oakes WJ; Luerssen TG; Walker ML; Drake JM; Kestle JR;
    J Neurosurg Pediatr; 2014 Aug; 14(2):173-8. PubMed ID: 24926971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Relationship of the location of the ventricular catheter tip and function of the ventriculoperitoneal shunt.
    Yamada SM; Kitagawa R; Teramoto A
    J Clin Neurosci; 2013 Jan; 20(1):99-101. PubMed ID: 22999561
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Frameless stereotactic placement of ventriculoperitoneal shunts in undersized ventricles: a simple modification to free-hand procedures.
    Woerdeman PA; Willems PW; Han KS; Hanlo PW; Berkelbach van der Sprenkel JW
    Br J Neurosurg; 2005 Dec; 19(6):484-7. PubMed ID: 16574560
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Factors affecting the accuracy of ventricular catheter placement.
    Wan KR; Toy JA; Wolfe R; Danks A
    J Clin Neurosci; 2011 Apr; 18(4):485-8. PubMed ID: 21256029
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A guide to placement of parietooccipital ventricular catheters. Technical note.
    Howard MA; Srinivasan J; Bevering CG; Winn HR; Grady MS
    J Neurosurg; 1995 Feb; 82(2):300-4. PubMed ID: 7815163
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shortening of ventricular shunt catheter associated with cranial growth: effect of the frontal and parieto-occipital access route on long-term shunt patency.
    Nakahara K; Shimizu S; Utsuki S; Suzuki S; Oka H; Yamada M; Kan S; Fujii K
    Childs Nerv Syst; 2009 Jan; 25(1):91-4. PubMed ID: 18769926
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Freehand stereotactic ventricular catheter insertion for ventriculoperitoneal shunts based on individualized radio-anatomical landmarks.
    Spitaels J; Riva M; Delpierre I; Dewitte O; Bruneau M
    Acta Neurochir (Wien); 2021 Apr; 163(4):1103-1112. PubMed ID: 33587186
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conversion of external ventricular drains to ventriculoperitoneal shunts after aneurysmal subarachnoid hemorrhage: effects of site and protein/red blood cell counts on shunt infection and malfunction.
    Rammos S; Klopfenstein J; Augspurger L; Wang H; Wagenbach A; Poston J; Lanzino G
    J Neurosurg; 2008 Dec; 109(6):1001-4. PubMed ID: 19035711
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Using a burr hole valve prevents proximal shunt failure in infants and toddlers.
    Hsu CH; Chou SC; Yang SH; Shih MC; Kuo MF
    J Neurosurg Pediatr; 2019 Jun; 24(3):315-322. PubMed ID: 31252383
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Late calcification and rupture: a rare complication of ventriculoperitoneal shunting.
    Kural C; Kirik A; Pusat S; Senturk T; Izci Y
    Turk Neurosurg; 2012; 22(6):779-82. PubMed ID: 23208915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel method for stereotactic, endoscope-assisted transtentorial placement of a shunt catheter into symptomatic posterior fossa cysts.
    Turner MS; Nguyen HS; Payner TD; Cohen-Gadol AA
    J Neurosurg Pediatr; 2011 Jul; 8(1):15-21. PubMed ID: 21721883
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation.
    Wilson TJ; Stetler WR; Al-Holou WN; Sullivan SE
    J Neurosurg; 2013 Jul; 119(1):66-70. PubMed ID: 23330995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.