These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Line spread function study of kinestatic charge detectors operating at high gas pressures. Giakos GC; Ghotra P; Pillai B; Chowdhury S; Vedantham S; Dibianca FA; Jordan LM; Devidas S; Nagarajan S; Endorf RJ J Xray Sci Technol; 1996 Jan; 6(4):343-58. PubMed ID: 21307533 [TBL] [Abstract][Full Text] [Related]
3. On modelling the kinestatic charge detector for digital radiographic diagnostic and portal imaging. Qi G; Goloubev MY; DiBianca FA; Samant S J Med Eng Technol; 2002; 26(5):193-8. PubMed ID: 12487709 [TBL] [Abstract][Full Text] [Related]
4. Signal Dependence on Irradiation Geometry of Cd1-xZnxTe Detectors for Digital X-Ray Imaging. Giakos GC; Vedantham S; Pillai B; Chowdhury S; Sheffer DB; Dasgupta A; Endorf RJ; Passalaqua A; Kollipara S J Xray Sci Technol; 1997 Jan; 7(3):295-304. PubMed ID: 21311126 [TBL] [Abstract][Full Text] [Related]
5. Use of a low ionization potential dopant in a kinestatic charge detector: experimental findings. Wagenaar DJ; DiBianca FA; Tenney CR; Reed MS; Vance JE Med Phys; 1991; 18(2):227-35. PubMed ID: 2046609 [TBL] [Abstract][Full Text] [Related]
6. Space charge effects in a kinestatic charge detector. Wagenaar DJ; DiBianca FA; Tenney CR; Fritsch D Phys Med Biol; 1991 Jan; 36(1):61-76. PubMed ID: 2006215 [TBL] [Abstract][Full Text] [Related]
12. An examination of automatic exposure control regimes for two digital radiography systems. Marshall NW Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115 [TBL] [Abstract][Full Text] [Related]
13. [Digital radiography: fundamentals and future potentials]. Doi K Nihon Igaku Hoshasen Gakkai Zasshi; 1989 Jan; 49(1):1-14. PubMed ID: 2660097 [TBL] [Abstract][Full Text] [Related]
14. Development of a two-dimensional virtual-pixel X-ray imaging detector for time-resolved structure research. Orthen A; Wagner H; Martoiu S; Amenitsch H; Bernstorff S; Besch HJ; Menk RH; Nurdan K; Rappolt M; Walenta AH; Werthenbach U J Synchrotron Radiat; 2004 Mar; 11(Pt 2):177-86. PubMed ID: 14960783 [TBL] [Abstract][Full Text] [Related]
15. Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator. Saw CB; Yang Y; Li F; Yue NJ; Ding C; Komanduri K; Huq S; Heron DE Med Dosim; 2007; 32(2):80-5. PubMed ID: 17472886 [TBL] [Abstract][Full Text] [Related]
16. [Chest radiography: ROC phantom study of four different digital systems and one conventional radiographic system]. Redlich U; Reissberg S; Hoeschen C; Effenberger O; Fessel A; Preuss H; Scherlach C; Döhring W Rofo; 2003 Jan; 175(1):38-45. PubMed ID: 12525979 [TBL] [Abstract][Full Text] [Related]
17. Charge detector for the measurement of ionic solutes. Yang B; Chen Y; Mori M; Ohira S; Azad AK; Dasgupta PK; Srinivasan K Anal Chem; 2010 Feb; 82(3):951-8. PubMed ID: 20055448 [TBL] [Abstract][Full Text] [Related]
18. [Imaging quality of a digital Konica Regius 336 system for thoracic radiology]. Ostinelli A; Frigerio M; Monti AF; Gelosa S; Tognoli P; Perniola N; Gozzi G Radiol Med; 2000 Jun; 99(6):465-8. PubMed ID: 11262825 [TBL] [Abstract][Full Text] [Related]