120 related articles for article (PubMed ID: 21321443)
21. Ion chromatography of nitrite at the ppb level with photometric measurement of iodine formed by post-column reaction of nitrite with iodide.
Miura Y; Hamada H
J Chromatogr A; 1999 Jul; 850(1-2):153-60. PubMed ID: 10457476
[TBL] [Abstract][Full Text] [Related]
22. Flow-injection analysis method for the determination of nitrite and nitrate in natural water samples using a chemiluminescence NOx monitor.
Kanda Y; Taira M
Anal Sci; 2003 May; 19(5):695-9. PubMed ID: 12769367
[TBL] [Abstract][Full Text] [Related]
23. C(18) columns for the simultaneous determination of oxytetracycline and its related substances by reversed-phase high performance liquid chromatography and UV detection.
Smyrniotakis CG; Archontaki HA
J Pharm Biomed Anal; 2007 Jan; 43(2):506-14. PubMed ID: 16989968
[TBL] [Abstract][Full Text] [Related]
24. Electrospray ionization-ion mobility spectrometry: a rapid analytical method for aqueous nitrate and nitrite analysis.
Dwivedi P; Matz LM; Atkinson DA; Hill HH
Analyst; 2004 Feb; 129(2):139-44. PubMed ID: 14752557
[TBL] [Abstract][Full Text] [Related]
25. A simple and high resolution ion-pair HPLC method for separation and simultaneous determination of nitrate and thiocyanate in different water samples.
Soleimani M; Yamini Y; Mohazab Rad F
J Chromatogr Sci; 2012 Oct; 50(9):826-30. PubMed ID: 22695882
[TBL] [Abstract][Full Text] [Related]
26. Fast separation of UV absorbing anions using ion-interaction chromatography.
Connolly D; Paull B
J Chromatogr A; 2001 May; 917(1-2):353-9. PubMed ID: 11403488
[TBL] [Abstract][Full Text] [Related]
27. Determination of nitrate by suppressed ion chromatography after copperised-cadmium column reduction.
Thabano JR; Abong'o D; Sawula GM
J Chromatogr A; 2004 Aug; 1045(1-2):153-9. PubMed ID: 15378890
[TBL] [Abstract][Full Text] [Related]
28. Ultra-sensitive HPLC-photochemical reaction-luminol chemiluminescence method for the measurement of secondary amines after nitrosation.
Kodamatani H; Iwaya Y; Saga M; Saito K; Fujioka T; Yamazaki S; Kanzaki R; Tomiyasu T
Anal Chim Acta; 2017 Feb; 952():50-58. PubMed ID: 28010842
[TBL] [Abstract][Full Text] [Related]
29. Simultaneous analysis of nitrate and nitrite in a microfluidic device with a Cu-complex-modified electrode.
Shiddiky MJ; Won MS; Shim YB
Electrophoresis; 2006 Nov; 27(22):4545-54. PubMed ID: 17058308
[TBL] [Abstract][Full Text] [Related]
30. The Determination of Nitrate and Nitrite in Human Urine and Blood by High-Performance Liquid Chromatography and Cloud-Point Extraction.
Zhao J; Wang J; Yang Y; Lu Y
J Chromatogr Sci; 2015 Aug; 53(7):1169-77. PubMed ID: 25616990
[TBL] [Abstract][Full Text] [Related]
31. Ion chromatographic method for the simultaneous determination of nitrite and nitrate by post-column indirect fluorescence detection.
Stalikas CD; Konidari CN; Nanos CG
J Chromatogr A; 2003 Jun; 1002(1-2):237-41. PubMed ID: 12885094
[TBL] [Abstract][Full Text] [Related]
32. An automatic gas-phase molecular absorption spectrometric system using a UV-LED photodiode based detector for determination of nitrite and total nitrate.
Zhang M; Zhang Z; Yuan D; Feng S; Liu B
Talanta; 2011 Apr; 84(2):443-50. PubMed ID: 21376971
[TBL] [Abstract][Full Text] [Related]
33. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection.
del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC
J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420
[TBL] [Abstract][Full Text] [Related]
34. An automatic reserve flow injection method using vanadium (III) reduction for simultaneous determination of nitrite and nitrate in estuarine and coastal waters.
Lin K; Li P; Ma J; Yuan D
Talanta; 2019 Apr; 195():613-618. PubMed ID: 30625591
[TBL] [Abstract][Full Text] [Related]
35. Highly sensitive method for determination of N-nitrosamines using high-performance liquid chromatography with online UV irradiation and luminol chemiluminescence detection.
Kodamatani H; Yamazaki S; Saito K; Amponsaa-Karikari A; Kishikawa N; Kuroda N; Tomiyasu T; Komatsu Y
J Chromatogr A; 2009 Jan; 1216(1):92-8. PubMed ID: 19062029
[TBL] [Abstract][Full Text] [Related]
36. A simple simultaneous flow injection method based on phosphomolybdenum chemistry for nitrate and nitrite determinations in water and fish samples.
Monser L; Sadok S; Greenway GM; Shah I; Uglow RF
Talanta; 2002 May; 57(3):511-8. PubMed ID: 18968650
[TBL] [Abstract][Full Text] [Related]
37. Rapid and direct determination of iodide in seawater by electrostatic ion chromatography.
Hu W; Yang PJ; Hasebe K; Haddad PR; Tanaka K
J Chromatogr A; 2002 May; 956(1-2):103-7. PubMed ID: 12108640
[TBL] [Abstract][Full Text] [Related]
38. Ion chromatographic determination of nitrate and nitrite in vegetable and fruit baby foods.
McMullen SE; Casanova JA; Gross LK; Schenck FJ
J AOAC Int; 2005; 88(6):1793-6. PubMed ID: 16526464
[TBL] [Abstract][Full Text] [Related]
39. A simple miniaturised photometrical method for rapid determination of nitrate and nitrite in freshwater.
Tu X; Xiao B; Xiong J; Chen X
Talanta; 2010 Aug; 82(3):976-83. PubMed ID: 20678655
[TBL] [Abstract][Full Text] [Related]
40. Optimum conditions for effective use of the terminating ion in transient isotachophoresis for capillary zone electrophoretic determination of nitrite and nitrate in seawater, with artificial seawater as background electrolyte.
Ishio N; Fukushi K; Michiba K; Takeda S; Wakida S
Anal Bioanal Chem; 2002 Nov; 374(6):1165-9. PubMed ID: 12458437
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]