These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

521 related articles for article (PubMed ID: 21325208)

  • 1. Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.
    Leite LR; Santos SN; Maia H; Henz BD; Giuseppin F; Oliverira A; Zanatta AR; Peres AK; Novakoski C; Barreto JR; Vassalo F; d'Avila A; Singh SM
    Circ Arrhythm Electrophysiol; 2011 Apr; 4(2):149-56. PubMed ID: 21325208
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prevalence of esophageal ulceration after atrial fibrillation ablation with the hot balloon ablation catheter: what is the value of esophageal cooling?
    Sohara H; Satake S; Takeda H; Yamaguchi Y; Nagasu N
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):686-92. PubMed ID: 24576252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Esophagus-Related Complications During Second-Generation Cryoballoon Ablation-Insight from Simultaneous Esophageal Temperature Monitoring from 2 Esophageal Probes.
    Miyazaki S; Nakamura H; Taniguchi H; Takagi T; Iwasawa J; Watanabe T; Hachiya H; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2016 Sep; 27(9):1038-44. PubMed ID: 27221011
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Esophageal injury and temperature monitoring during atrial fibrillation ablation.
    Singh SM; d'Avila A; Doshi SK; Brugge WR; Bedford RA; Mela T; Ruskin JN; Reddy VY
    Circ Arrhythm Electrophysiol; 2008 Aug; 1(3):162-8. PubMed ID: 19808410
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes.
    Müller P; Dietrich JW; Halbfass P; Abouarab A; Fochler F; Szöllösi A; Nentwich K; Roos M; Krug J; Schade A; Mügge A; Deneke T
    Heart Rhythm; 2015 Jul; 12(7):1464-9. PubMed ID: 25847474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases.
    Mateos JC; Mateos EI; Peña TG; Lobo TJ; Mateos JC; Vargas RN; Pachón CT; Acosta JC
    Rev Bras Cir Cardiovasc; 2015; 30(2):139-47. PubMed ID: 26107444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Esophageal damage during radiofrequency ablation of atrial fibrillation: impact of energy settings, lesion sets, and esophageal visualization.
    Martinek M; Bencsik G; Aichinger J; Hassanein S; Schoefl R; Kuchinka P; Nesser HJ; Purerfellner H
    J Cardiovasc Electrophysiol; 2009 Jul; 20(7):726-33. PubMed ID: 19207781
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility, safety, and efficacy of a novel preshaped nitinol esophageal deviator to successfully deflect the esophagus and ablate left atrium without esophageal temperature rise during atrial fibrillation ablation: The DEFLECT GUT study.
    Parikh V; Swarup V; Hantla J; Vuddanda V; Dar T; Yarlagadda B; Di Biase L; Al-Ahmad A; Natale A; Lakkireddy D
    Heart Rhythm; 2018 Sep; 15(9):1321-1327. PubMed ID: 29678784
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incidences of esophageal injury during esophageal temperature monitoring: a comparative study of a multi-thermocouple temperature probe and a deflectable temperature probe in atrial fibrillation ablation.
    Kuwahara T; Takahashi A; Takahashi Y; Okubo K; Takagi K; Fujino T; Kusa S; Takigawa M; Watari Y; Yamao K; Nakashima E; Kawaguchi N; Hikita H; Sato A; Aonuma K
    J Interv Card Electrophysiol; 2014 Apr; 39(3):251-7. PubMed ID: 24532111
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias.
    Halm U; Gaspar T; Zachäus M; Sack S; Arya A; Piorkowski C; Knigge I; Hindricks G; Husser D
    Am J Gastroenterol; 2010 Mar; 105(3):551-6. PubMed ID: 19888201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrical and thermal effects of esophageal temperature probes on radiofrequency catheter ablation of atrial fibrillation: results from a computational modeling study.
    Pérez JJ; D'Avila A; Aryana A; Berjano E
    J Cardiovasc Electrophysiol; 2015 May; 26(5):556-64. PubMed ID: 25648533
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The transesophageal echo probe may contribute to esophageal injury after catheter ablation for paroxysmal atrial fibrillation under general anesthesia: a preliminary observation.
    Kumar S; Brown G; Sutherland F; Morgan J; Andrews D; Ling LH; McLELLAN AJ; Lee G; Robinson T; Heck P; Halloran K; Morton J; Kistler P; Kalman JM; Sparks PB
    J Cardiovasc Electrophysiol; 2015 Feb; 26(2):119-26. PubMed ID: 25352207
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature monitoring and temperature-driven irrigated radiofrequency energy titration do not prevent thermally induced esophageal lesions in pulmonary vein isolation: A randomized study controlled by esophagoscopy before and after catheter ablation.
    Grosse Meininghaus D; Blembel K; Waniek C; Kruells-Muench J; Ernst H; Kleemann T; Geller JC
    Heart Rhythm; 2021 Jun; 18(6):926-934. PubMed ID: 33561587
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation.
    Deneke T; Bünz K; Bastian A; Päsler M; Anders H; Lehmann R; Meuser W; de Groot JR; Horlitz M; Haberkorn R; Mügge A; Shin DI
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):255-61. PubMed ID: 20958829
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique.
    Fürnkranz A; Chun KR; Metzner A; Nuyens D; Schmidt B; Burchard A; Tilz R; Ouyang F; Kuck KH
    J Cardiovasc Electrophysiol; 2010 Aug; 21(8):869-74. PubMed ID: 20233270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-sensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared to single-sensor probe.
    Carroll BJ; Contreras-Valdes FM; Heist EK; Barrett CD; Danik SB; Ruskin JN; Mansour M
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):958-64. PubMed ID: 23746064
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation.
    Di Biase L; Saenz LC; Burkhardt DJ; Vacca M; Elayi CS; Barrett CD; Horton R; Bai R; Siu A; Fahmy TS; Patel D; Armaganijan L; Wu CT; Kai S; Ching CK; Phillips K; Schweikert RA; Cummings JE; Arruda M; Saliba WI; Dodig M; Natale A
    Circ Arrhythm Electrophysiol; 2009 Apr; 2(2):108-12. PubMed ID: 19808454
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The esophageal temperature probe: helpful monitoring device or inadvertent amplifier of risk?
    Musat D; Mittal S
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):262-4. PubMed ID: 20958839
    [No Abstract]   [Full Text] [Related]  

  • 19. Reliability of luminal oesophageal temperature monitoring during radiofrequency ablation of atrial fibrillation: insights from probe visualization and oesophageal reconstruction using magnetic resonance imaging.
    Knecht S; Sticherling C; Reichlin T; Mühl A; Pavlovic N; Schaer B; Osswald S; Kühne M
    Europace; 2017 Jul; 19(7):1123-1131. PubMed ID: 27358070
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ablation of atrial fibrillation and esophageal injury: Role of bipolar and unipolar energy using a novel multipolar irrigated ablation catheter.
    Di Monaco A; Quadrini F; Katsouras G; Caccavo V; Troisi F; Quatraro F; Cecere G; Langialonga T; Grimaldi M
    Heart Rhythm; 2015 Jun; 12(6):1120-7. PubMed ID: 25766775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.