These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
317 related articles for article (PubMed ID: 21328697)
1. A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3. Higashi T; Suzuki M; Hanai J; Inagaki S; Min JZ; Shimada K; Toyo'oka T J Sep Sci; 2011 Apr; 34(7):725-32. PubMed ID: 21328697 [TBL] [Abstract][Full Text] [Related]
2. A novel Cookson-type reagent for enhancing sensitivity and specificity in assessment of infant vitamin D status using liquid chromatography/tandem mass spectrometry. Ogawa S; Ooki S; Morohashi M; Yamagata K; Higashi T Rapid Commun Mass Spectrom; 2013 Nov; 27(21):2453-60. PubMed ID: 24097402 [TBL] [Abstract][Full Text] [Related]
3. Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D Ogawa S; Kittaka H; Nakata A; Komatsu K; Sugiura T; Satoh M; Nomura F; Higashi T J Pharm Biomed Anal; 2017 Mar; 136():126-133. PubMed ID: 28081498 [TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of new Cookson-type reagents for LC/ESI-MS/MS assay of 25-hydroxyvitamin D3 in neonatal blood samples. Ogawa S; Kittaka H; Shinoda K; Ooki S; Nakata A; Higashi T Biomed Chromatogr; 2016 Jun; 30(6):938-45. PubMed ID: 26451531 [TBL] [Abstract][Full Text] [Related]
5. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum. van den Ouweland JM; Beijers AM; van Daal H J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396 [TBL] [Abstract][Full Text] [Related]
6. Development and validation of a method for determination of plasma 25-hydroxyvitamin D3 3-sulfate using liquid chromatography/tandem mass spectrometry. Higashi T; Goto A; Morohashi M; Ogawa S; Komatsu K; Sugiura T; Fukuoka T; Mitamura K J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Oct; 969():230-4. PubMed ID: 25195024 [TBL] [Abstract][Full Text] [Related]
7. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma. Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873 [TBL] [Abstract][Full Text] [Related]
8. Liquid chromatography-tandem mass spectrometric method for the determination of salivary 25-hydroxyvitamin D3: a noninvasive tool for the assessment of vitamin D status. Higashi T; Shibayama Y; Fuji M; Shimada K Anal Bioanal Chem; 2008 May; 391(1):229-38. PubMed ID: 18087693 [TBL] [Abstract][Full Text] [Related]
9. A sensitive LC/MS/MS assay of 25OH vitamin D3 and 25OH vitamin D2 in dried blood spots. Eyles D; Anderson C; Ko P; Jones A; Thomas A; Burne T; Mortensen PB; Nørgaard-Pedersen B; Hougaard DM; McGrath J Clin Chim Acta; 2009 May; 403(1-2):145-51. PubMed ID: 19232332 [TBL] [Abstract][Full Text] [Related]
10. Quantification of the 3α and 3β epimers of 25-hydroxyvitamin D Müller MJ; Stokes CS; Volmer DA Talanta; 2017 Apr; 165():398-404. PubMed ID: 28153274 [TBL] [Abstract][Full Text] [Related]
11. Analysis of urinary vitamin D₃ metabolites by liquid chromatography/tandem mass spectrometry with ESI-enhancing and stable isotope-coded derivatization. Ogawa S; Ooki S; Shinoda K; Higashi T Anal Bioanal Chem; 2014 Oct; 406(26):6647-54. PubMed ID: 25168117 [TBL] [Abstract][Full Text] [Related]
12. Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: a comparative study. Bogusz MJ; Al Enazi E; Tahtamoni M; Jawaad JA; Al Tufail M Clin Biochem; 2011 Nov; 44(16):1329-37. PubMed ID: 21907190 [TBL] [Abstract][Full Text] [Related]
13. Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency. Saenger AK; Laha TJ; Bremner DE; Sadrzadeh SM Am J Clin Pathol; 2006 Jun; 125(6):914-20. PubMed ID: 16690491 [TBL] [Abstract][Full Text] [Related]
14. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications. Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091 [TBL] [Abstract][Full Text] [Related]
15. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation. Bruce SJ; Rochat B; Béguin A; Pesse B; Guessous I; Boulat O; Henry H Rapid Commun Mass Spectrom; 2013 Jan; 27(1):200-6. PubMed ID: 23239334 [TBL] [Abstract][Full Text] [Related]
16. A Method for Simultaneous Determination of 25-Hydroxyvitamin D3 and Its 3-Sulfate in Newborn Plasma by LC/ESI-MS/MS after Derivatization with a Proton-Affinitive Cookson-Type Reagent. Higashi T; Yokota M; Goto A; Komatsu K; Sugiura T; Ogawa S; Satoh M; Nomura F Mass Spectrom (Tokyo); 2016; 5(Spec Iss):S0051. PubMed ID: 27656337 [TBL] [Abstract][Full Text] [Related]
17. Ferrocene-based Diels-Alder derivatization for the determination of 1alpha-hydroxyvitamin D3 in rat plasma by high-performance liquid chromatography-electrospray tandem mass spectrometry. Murao N; Ishigai M; Sekiguchi N; Takahashi T; Aso Y Anal Biochem; 2005 Nov; 346(1):158-66. PubMed ID: 16169508 [TBL] [Abstract][Full Text] [Related]
18. Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. Schleicher RL; Encisco SE; Chaudhary-Webb M; Paliakov E; McCoy LF; Pfeiffer CM Clin Chim Acta; 2011 Aug; 412(17-18):1594-9. PubMed ID: 21601563 [TBL] [Abstract][Full Text] [Related]
19. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays. Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879 [TBL] [Abstract][Full Text] [Related]
20. A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry. Knox S; Harris J; Calton L; Wallace AM Ann Clin Biochem; 2009 May; 46(Pt 3):226-30. PubMed ID: 19389886 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]