BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

388 related articles for article (PubMed ID: 21330155)

  • 1. Medial support by fibula bone graft in angular stable plate fixation of proximal humeral fractures: an in vitro study with synthetic bone.
    Osterhoff G; Baumgartner D; Favre P; Wanner GA; Gerber H; Simmen HP; Werner CM
    J Shoulder Elbow Surg; 2011 Jul; 20(5):740-6. PubMed ID: 21330155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures.
    Hsiao CK; Tsai YJ; Yen CY; Lee CH; Yang TY; Tu YK
    BMC Musculoskelet Disord; 2017 Feb; 18(1):64. PubMed ID: 28153021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical study of Proximal humeral fracture fixation: Locking plate with medial support screw vs. locking plate with intramedullary fibular graft.
    Jang Y; Kim D
    Clin Biomech (Bristol, Avon); 2021 Dec; 90():105510. PubMed ID: 34673363
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Proximal humeral fracture fixation: locking plate construct ± intramedullary fibular allograft.
    Chow RM; Begum F; Beaupre LA; Carey JP; Adeeb S; Bouliane MJ
    J Shoulder Elbow Surg; 2012 Jul; 21(7):894-901. PubMed ID: 21782474
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
    Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.
    Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR
    J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft.
    Mathison C; Chaudhary R; Beaupre L; Reynolds M; Adeeb S; Bouliane M
    Clin Biomech (Bristol, Avon); 2010 Aug; 25(7):642-6. PubMed ID: 20483189
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus.
    Bae JH; Oh JK; Chon CS; Oh CW; Hwang JH; Yoon YC
    J Bone Joint Surg Br; 2011 Jul; 93(7):937-41. PubMed ID: 21705567
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Which additional augmented fixation procedure decreases surgical failure after proximal humeral fracture with medial comminution: fibular allograft or inferomedial screws?
    Kim DS; Lee DH; Chun YM; Shin SJ
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1852-1858. PubMed ID: 29735375
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus.
    Matassi F; Angeloni R; Carulli C; Civinini R; Di Bella L; Redl B; Innocenti M
    Injury; 2012 Nov; 43(11):1939-42. PubMed ID: 22921382
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis.
    Yang P; Zhang Y; Liu J; Xiao J; Ma LM; Zhu CR
    Acta Orthop Traumatol Turc; 2015; 49(2):203-9. PubMed ID: 26012943
    [TBL] [Abstract][Full Text] [Related]  

  • 12. No Contribution of Tension-Reducing Rotator Cuff Sutures on Locking Plate Fixation in a 2-Part Proximal Humerus Fracture Model.
    Sinatra PM; Jernick ML; Bledsoe G; Kaar SG
    J Orthop Trauma; 2014 Aug; 28(8):458-63. PubMed ID: 24375272
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.
    Röderer G; Scola A; Schmölz W; Gebhard F; Windolf M; Hofmann-Fliri L
    Injury; 2013 Oct; 44(10):1327-32. PubMed ID: 23769470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Locking plate fixation with and without inferomedial screws for proximal humeral fractures: a biomechanical study.
    Burke NG; Kennedy J; Cousins G; Fitzpatrick D; Mullett H
    J Orthop Surg (Hong Kong); 2014 Aug; 22(2):190-4. PubMed ID: 25163953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures.
    Schliemann B; Risse N; Frank A; Müller M; Michel P; Raschke MJ; Katthagen JC
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():21-26. PubMed ID: 30784787
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Type C2 proximal humeral fracture fixation using locking-plate with an intramedullary fibular allograft].
    Chen X; Chen H; Zou Y; Feng H; Wu J; Zhang J; Peng Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Feb; 28(2):201-4. PubMed ID: 24796193
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Locking plate fixation of proximal humeral fractures with impaction of the fracture site to restore medial column support: a biomechanical study.
    Weeks CA; Begum F; Beaupre LA; Carey JP; Adeeb S; Bouliane MJ
    J Shoulder Elbow Surg; 2013 Nov; 22(11):1552-7. PubMed ID: 23639833
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of screw length on predicted cut-out failures for proximal humeral fracture fixations predicted by finite element simulations.
    Fletcher JWA; Windolf M; Grünwald L; Richards RG; Gueorguiev B; Varga P
    Arch Orthop Trauma Surg; 2019 Aug; 139(8):1069-1074. PubMed ID: 30895465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
    Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures.
    Jabran A; Peach C; Zou Z; Ren L
    Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.