BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 21330984)

  • 1. A new approach to measure dwell position inaccuracy in HDR ring applicators - quantification and corrective QA.
    Jangda AQ; Hussein S; Rehman Z
    J Appl Clin Med Phys; 2010 Sep; 12(1):3355. PubMed ID: 21330984
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dwell position inaccuracy in the Varian GammaMed HDR ring applicator.
    Stern RL; Liu T
    J Appl Clin Med Phys; 2010 Sep; 11(4):3158. PubMed ID: 21081871
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel system for commissioning brachytherapy applicators: example of a ring applicator.
    Fonseca GP; Van den Bosch MR; Voncken R; Podesta M; Verhaegen F
    Phys Med Biol; 2017 Oct; 62(21):8360-8375. PubMed ID: 28914613
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas.
    Awunor O; Berger D; Kirisits C
    Med Phys; 2015 Aug; 42(8):4472-83. PubMed ID: 26233177
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Source position measurement by Cherenkov emission imaging from applicators for high-dose-rate brachytherapy.
    Yogo K; Noguchi Y; Okudaira K; Nozawa M; Ishiyama H; Okamoto H; Yasuda H; Oguchi H; Yamamoto S
    Med Phys; 2021 Jan; 48(1):488-499. PubMed ID: 33216999
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical evaluation of the Bravos afterloader system for HDR brachytherapy.
    Bellezzo M; Baeza JA; Voncken R; Reniers B; Verhaegen F; Fonseca GP
    Brachytherapy; 2019; 18(6):852-862. PubMed ID: 31327634
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance.
    Guiral P; Ribouton J; Jalade P; Wang R; Galvan JM; Lu GN; Pittet P; Rivoire A; Gindraux L
    Med Phys; 2016 Sep; 43(9):5240. PubMed ID: 27587055
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct reconstruction and associated uncertainties of 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients.
    Awunor OA; Dixon B; Walker C
    Phys Med Biol; 2013 May; 58(10):3207-25. PubMed ID: 23603854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
    Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SU-E-T-138: Quantification of Dwell Position Inaccuracy in Varian GammaMed HDR Titanium Ring Applicators.
    Iftimia I; Cirino E; Mower H; McKee A
    Med Phys; 2012 Jun; 39(6Part11):3735. PubMed ID: 28517159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quality assurance measurements for high-dose-rate brachytherapy without film.
    Jursinic P
    J Appl Clin Med Phys; 2014 Jan; 15(1):4586. PubMed ID: 24423858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.
    McMahon R; Zhuang T; Steffey BA; Song H; Craciunescu OI
    J Appl Clin Med Phys; 2011 Nov; 12(4):3447. PubMed ID: 22089000
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fluorescent screen for high-dose-rate (HDR) brachytherapy quality assurance.
    Lightstone AW
    Med Dosim; 2005; 30(3):143-4. PubMed ID: 16112464
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy.
    Kellermeier M; Herbolzheimer J; Kreppner S; Lotter M; Strnad V; Bert C
    J Appl Clin Med Phys; 2017 Jan; 18(1):211-222. PubMed ID: 28291934
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric comparison of ring and ovoid applicators.
    Tuncell N; Toy A; Demiral AN; Cetingoz R; Garipagaoglu M
    J BUON; 2009; 14(3):451-5. PubMed ID: 19810138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of an HDR-BT QA tool for source position verification.
    Kumazaki Y; Hirai R; Igari M; Kobayashi N; Okazaki S; Abe T; Tamaki T; Noda SE; Kato S
    J Appl Clin Med Phys; 2020 Dec; 21(12):84-89. PubMed ID: 33136313
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Practical experience commissioning MRI-compatible tandem and ring applicators for use with the Bravos HDR afterloader.
    Fagerstrom JM
    J Appl Clin Med Phys; 2023 Nov; 24(11):e14094. PubMed ID: 37469228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and evaluation of a HDR skin applicator with flattening filter.
    Granero D; Pérez-Calatayud J; Gimeno J; Ballester F; Casal E; Crispín V; van der Laarse R
    Med Phys; 2008 Feb; 35(2):495-503. PubMed ID: 18383670
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method.
    Jiang H; Badkul R; Pokhrel D
    J Appl Clin Med Phys; 2018 May; 19(3):101-107. PubMed ID: 29493101
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
    Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.