These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 21332564)

  • 1. Use of a genetic algorithm for multiobjective design optimization of the femoral stem of a cemented total hip arthroplasty.
    Ishida T; Nishimura I; Tanino H; Higa M; Ito H; Mitamura Y
    Artif Organs; 2011 Apr; 35(4):404-10. PubMed ID: 21332564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of femoral prosthesis design on cement strain in cemented total hip arthroplasty.
    Peters CL; Bachus KN; Craig MA; Higginbotham TO
    J Arthroplasty; 2001 Feb; 16(2):216-24. PubMed ID: 11222897
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses.
    Ramos A; Simões JA
    J Biomech; 2009 Nov; 42(15):2602-10. PubMed ID: 19660758
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
    O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
    J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of stem geometry on mechanics of cemented femoral hip components with a proximal bond.
    Mann KA; Bartel DL; Ayers DC
    J Orthop Res; 1997 Sep; 15(5):700-6. PubMed ID: 9420599
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Early aseptic loosening of the CF 30 femoral stem].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cement mantle fatigue failure in total hip replacement: experimental and computational testing.
    Jeffers JR; Browne M; Lennon AB; Prendergast PJ; Taylor M
    J Biomech; 2007; 40(7):1525-33. PubMed ID: 17070816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of three-dimensional shape optimization on the probabilistic response of a cemented femoral hip prosthesis.
    Nicolella DP; Thacker BH; Katoozian H; Davy DT
    J Biomech; 2006; 39(7):1265-78. PubMed ID: 15961093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of stem geometry on stresses within the distal cement mantle in total hip replacement.
    Schmölz W; Gordon DR; Shields AJ; Kirkwood D; Grigoris P
    Technol Health Care; 2000; 8(1):67-73. PubMed ID: 10942992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Failure of cementless fixation of the femoral component in total hip arthroplasty.
    Otani T; Whiteside LA
    Orthop Clin North Am; 1992 Apr; 23(2):335-46. PubMed ID: 1570145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new design of cemented stem using functionally graded materials (FGM).
    Hedia HS; Aldousari SM; Abdellatif AK; Fouda N
    Biomed Mater Eng; 2014; 24(3):1575-88. PubMed ID: 24840196
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.
    Cheal EJ; Spector M; Hayes WC
    J Orthop Res; 1992 May; 10(3):405-22. PubMed ID: 1569504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A finite element study of the initiation of failure of fixation in cemented femoral total hip components.
    Harrigan TP; Kareh JA; O'Connor DO; Burke DW; Harris WH
    J Orthop Res; 1992 Jan; 10(1):134-44. PubMed ID: 1727933
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cemented femoral stem performance. Effects of proximal bonding, geometry, and neck length.
    Chang PB; Mann KA; Bartel DL
    Clin Orthop Relat Res; 1998 Oct; (355):57-69. PubMed ID: 9917591
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of different hip prosthesis shapes considering micro-level bone remodeling and stress-shielding criteria using three-dimensional design space topology optimization.
    Boyle C; Kim IY
    J Biomech; 2011 Jun; 44(9):1722-8. PubMed ID: 21497816
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Probabilistic analysis of the influence of the bonding degree of the stem-cement interface in the performance of cemented hip prostheses.
    Pérez MA; Grasa J; García-Aznar JM; Bea JA; Doblaré M
    J Biomech; 2006; 39(10):1859-72. PubMed ID: 16054633
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cement mantle stress under retroversion torque at heel-strike.
    Afsharpoya B; Barton DC; Fisher J; Purbach B; Wroblewski M; Stewart TD
    Med Eng Phys; 2009 Dec; 31(10):1323-30. PubMed ID: 19879794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.