These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 21333860)

  • 1. Dark field electron holography for strain measurement.
    Béché A; Rouvière JL; Barnes JP; Cooper D
    Ultramicroscopy; 2011 Feb; 111(3):227-38. PubMed ID: 21333860
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Strain measurement at the nanoscale: Comparison between convergent beam electron diffraction, nano-beam electron diffraction, high resolution imaging and dark field electron holography.
    Béché A; Rouvière JL; Barnes JP; Cooper D
    Ultramicroscopy; 2013 Aug; 131():10-23. PubMed ID: 23673283
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Practical aspects of strain measurement in thin SiGe layers by (004) dark-field electron holography in Lorentz mode.
    Denneulin T; Cooper D; Rouviere JL
    Micron; 2014 Jul; 62():52-65. PubMed ID: 24811992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dark-field electron holography for the measurement of geometric phase.
    Hÿtch MJ; Houdellier F; Hüe F; Snoeck E
    Ultramicroscopy; 2011 Jul; 111(8):1328-37. PubMed ID: 21864773
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Strain mapping in a nanoscale-triangular SiGe pattern by dark-field electron holography with medium magnification mode.
    Hoang VV; Cho Y; Yoo JH; Hong SK; Choi YH; Choi S; Jung W; Jeong CK; Yang JM
    Microscopy (Oxf); 2016 Dec; 65(6):499-507. PubMed ID: 27609112
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Off-axis electron holography combining summation of hologram series with double-exposure phase-shifting: Theory and application.
    Boureau V; McLeod R; Mayall B; Cooper D
    Ultramicroscopy; 2018 Oct; 193():52-63. PubMed ID: 29935412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electron beam coherence measurements using diffracted beam interferometry/holography.
    Herring RA
    J Electron Microsc (Tokyo); 2009 Jun; 58(3):213-21. PubMed ID: 19141592
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phase-shifting electron holography for atomic image reconstruction.
    Yamamoto K; Sugawara Y; McCartney MR; Smith DJ
    J Electron Microsc (Tokyo); 2010 Aug; 59 Suppl 1():S81-8. PubMed ID: 20543160
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Imaging modes for potential mapping in semiconductor devices by electron holography with improved lateral resolution.
    Sickmann J; Formánek P; Linck M; Muehle U; Lichte H
    Ultramicroscopy; 2011 Mar; 111(4):290-302. PubMed ID: 21353156
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nanoscale holographic interferometry for strain measurements in electronic devices.
    Hÿtch M; Houdellier F; Hüe F; Snoeck E
    Nature; 2008 Jun; 453(7198):1086-9. PubMed ID: 18563161
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differential phase-contrast dark-field electron holography for strain mapping.
    Denneulin T; Houdellier F; Hÿtch M
    Ultramicroscopy; 2016 Jan; 160():98-109. PubMed ID: 26476802
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of JEOL 2100F Lorentz-TEM for low-magnification electron holography and magnetic imaging.
    Schofield MA; Beleggia M; Zhu Y; Pozzi G
    Ultramicroscopy; 2008 Jun; 108(7):625-34. PubMed ID: 18328628
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Averaging scheme for atomic resolution off-axis electron holograms.
    Niermann T; Lehmann M
    Micron; 2014 Aug; 63():28-34. PubMed ID: 24568718
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Realization of a tilted reference wave for electron holography by means of a condenser biprism.
    Röder F; Houdellier F; Denneulin T; Snoeck E; Hÿtch M
    Ultramicroscopy; 2016 Feb; 161():23-40. PubMed ID: 26624513
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strain mapping of LED devices by dark-field inline electron holography: comparison between deterministic and iterative phase retrieval approaches.
    Song K; Shin GY; Kim JK; Oh SH; Koch CT
    Ultramicroscopy; 2013 Apr; 127():119-25. PubMed ID: 22910615
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental quantification of annular dark-field images in scanning transmission electron microscopy.
    Lebeau JM; Stemmer S
    Ultramicroscopy; 2008 Nov; 108(12):1653-8. PubMed ID: 18707809
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tutorial on off-axis electron holography.
    Lehmann M; Lichte H
    Microsc Microanal; 2002 Dec; 8(6):447-66. PubMed ID: 12533207
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Visualization of different carrier concentrations in n-type-GaN semiconductors by phase-shifting electron holography with multiple electron biprisms.
    Yamamoto K; Nakano K; Tanaka A; Honda Y; Ando Y; Ogura M; Matsumoto M; Anada S; Ishikawa Y; Amano H; Hirayama T
    Microscopy (Oxf); 2020 Mar; 69(1):1-10. PubMed ID: 31711167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of the elliptical illumination on acquisition and correction of coherent aberrations in high-resolution electron holography.
    Lehmann M
    Ultramicroscopy; 2004 Jul; 100(1-2):9-23. PubMed ID: 15219689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thin dielectric film thickness determination by advanced transmission electron microscopy.
    Diebold AC; Foran B; Kisielowski C; Muller DA; Pennycook SJ; Principe E; Stemmer S
    Microsc Microanal; 2003 Dec; 9(6):493-508. PubMed ID: 14750984
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.