190 related articles for article (PubMed ID: 21335649)
1. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.
Gu Y; Matteson JL; Skelton RT; Deal AC; Stephan EA; Duttweiler F; Gasaway TM; Levin CS
Phys Med Biol; 2011 Mar; 56(6):1563-84. PubMed ID: 21335649
[TBL] [Abstract][Full Text] [Related]
2. Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system.
Abbaszadeh S; Gu Y; Reynolds PD; Levin CS
Phys Med Biol; 2016 Sep; 61(18):6733-6753. PubMed ID: 27551981
[TBL] [Abstract][Full Text] [Related]
3. Study of electrode pattern design for a CZT-based PET detector.
Gu Y; Levin CS
Phys Med Biol; 2014 Jun; 59(11):2599-621. PubMed ID: 24786208
[TBL] [Abstract][Full Text] [Related]
4. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors.
Peng H; Levin CS
Phys Med Biol; 2010 May; 55(9):2761-88. PubMed ID: 20400807
[TBL] [Abstract][Full Text] [Related]
5. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
Habte F; Foudray AM; Olcott PD; Levin CS
Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
[TBL] [Abstract][Full Text] [Related]
6. A simulation of a high-resolution cadmium zinc telluride positron emission tomography system.
Stanford-Hill R; Groll A; Levin CS
Med Phys; 2024 Feb; 51(2):1340-1350. PubMed ID: 38100261
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo investigation of charge-transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applications.
Myronakis ME; Darambara DG
Med Phys; 2011 Jan; 38(1):455-67. PubMed ID: 21361214
[TBL] [Abstract][Full Text] [Related]
8. Positioning true coincidences that undergo inter-and intra-crystal scatter for a sub-mm resolution cadmium zinc telluride-based PET system.
Abbaszadeh S; Chinn G; Levin CS
Phys Med Biol; 2018 Jan; 63(2):025012. PubMed ID: 29131809
[TBL] [Abstract][Full Text] [Related]
9. Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors.
Enlow E; Diba M; Clayton J; Harris B; Abbaszadeh S
IEEE Trans Radiat Plasma Med Sci; 2023 Jul; 7(6):580-586. PubMed ID: 38468608
[TBL] [Abstract][Full Text] [Related]
10. New-generation small animal positron emission tomography system for molecular imaging.
Abbaszadeh S; Levin CS
J Med Imaging (Bellingham); 2017 Jan; 4(1):011008. PubMed ID: 28097211
[TBL] [Abstract][Full Text] [Related]
11. Performance of long rectangular semi-monolithic scintillator PET detectors.
Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
[TBL] [Abstract][Full Text] [Related]
12. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications.
Komarov S; Yin Y; Wu H; Wen J; Krawczynski H; Meng LJ; Tai YC
Phys Med Biol; 2012 Nov; 57(22):7355-80. PubMed ID: 23079763
[TBL] [Abstract][Full Text] [Related]
13. Improved x-ray spectroscopy with room temperature CZT detectors.
Fritz SG; Shikhaliev PM; Matthews KL
Phys Med Biol; 2011 Sep; 56(17):5735-51. PubMed ID: 21841213
[TBL] [Abstract][Full Text] [Related]
14. Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.
Abbene L; Gerardi G; Principato F; Buttacavoli A; Altieri S; Protti N; Tomarchio E; Del Sordo S; Auricchio N; Bettelli M; Amadè NS; Zanettini S; Zappettini A; Caroli E
J Synchrotron Radiat; 2020 Nov; 27(Pt 6):1564-1576. PubMed ID: 33147181
[TBL] [Abstract][Full Text] [Related]
15. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
Shikhaliev PM
Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
[TBL] [Abstract][Full Text] [Related]
16. Development and Characterization of Modular Readout Design for Two-Panel Head-and-Neck Dedicated PET System Based on CZT Detectors.
Wang Y; Herbst R; Abbaszadeh S
IEEE Trans Radiat Plasma Med Sci; 2022 May; 6(5):517-521. PubMed ID: 37711549
[TBL] [Abstract][Full Text] [Related]
17. An edge-readout, multilayer detector for positron emission tomography.
Li X; Ruiz-Gonzalez M; Furenlid LR
Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
[TBL] [Abstract][Full Text] [Related]
18. CZT detectors used in different irradiation geometries: simulations and experimental results.
Fritz SG; Shikhaliev PM
Med Phys; 2009 Apr; 36(4):1098-108. PubMed ID: 19472614
[TBL] [Abstract][Full Text] [Related]
19. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
Shikhaliev PM; Fritz SG; Chapman JW
Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
[TBL] [Abstract][Full Text] [Related]
20. Optimizing timing performance of CdTe detectors for PET.
Nakhostin M
Phys Med Biol; 2017 Sep; 62(19):N485-N505. PubMed ID: 28809758
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]