These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
251 related articles for article (PubMed ID: 2133726)
1. [The 19mm St. Jude Medical prosthetic aortic valve evaluated by long-term hemodynamic sequelae]. Oka K; Hadama T; Takasaki H; Mori Y; Shigemitsu O; Shirabe J J Cardiol; 1990; 20(4):917-28. PubMed ID: 2133726 [TBL] [Abstract][Full Text] [Related]
2. Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement. Lund O; Dørup I; Emmertsen K; Jensen FT; Flø C Scand Cardiovasc J; 2005 Sep; 39(4):237-43. PubMed ID: 16118072 [TBL] [Abstract][Full Text] [Related]
3. [Rest and exercise performance of allografts, Bicer valves and St. Jude Medical valves in the aortic position]. Hasegawa J; Kitamura S; Kawachi K; Kawata T; Niwaya K; Kameda Y; Mizuguchi K; Kobayashi S; Yoshida Y Nihon Kyobu Geka Gakkai Zasshi; 1995 Aug; 43(8):1132-7. PubMed ID: 7594847 [TBL] [Abstract][Full Text] [Related]
5. Hemodynamics of St. Jude Medical prostheses in the small aortic root: in vivo studies using dobutamine Doppler echocardiography. Kadir I; Izzat MB; Birdi I; Wilde P; Reeves B; Bryan AJ; Angelini GD J Heart Valve Dis; 1997 Mar; 6(2):123-9. PubMed ID: 9130118 [TBL] [Abstract][Full Text] [Related]
6. Hemodynamics after aortic valve replacement with St. Jude Medical valve for patients with small aortic annulus and severe left ventricular hypertrophy. Natsuaki M; Itoh T; Tomita S; Naitoh K J Heart Valve Dis; 1998 Jan; 7(1):86-93. PubMed ID: 9502145 [TBL] [Abstract][Full Text] [Related]
7. Influence of St. Jude medical valve in patients with aortic stenosis and small aortic annulus on cardiac function and late survival result. Natsuaki M; Itoh T; Okazaki Y; Takarabe K; Furukawa K; Rikitake K; Ohtubo S Artif Organs; 2002 Oct; 26(10):840-6. PubMed ID: 12296922 [TBL] [Abstract][Full Text] [Related]
8. Comparison of On-X and SJM HP bileaflet aortic valves. Walther T; Falk V; Tigges R; Krüger M; Langebartels G; Diegeler A; Autschbach R; Mohr FW J Heart Valve Dis; 2000 May; 9(3):403-7. PubMed ID: 10888098 [TBL] [Abstract][Full Text] [Related]
9. Small aortic annulus: a functional definition. Ghosh P; Kumar S; Pandey S; Kumar AS; Sinha N Ann Thorac Cardiovasc Surg; 1998 Oct; 4(5):251-61. PubMed ID: 9828282 [TBL] [Abstract][Full Text] [Related]
10. [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve]. Shimabukuro T; Takeuchi Y; Gomi A; Nakatani H; Suda Y; Kono K; Nagano N Jpn J Thorac Cardiovasc Surg; 1998 Dec; 46(12):1285-91. PubMed ID: 10037837 [TBL] [Abstract][Full Text] [Related]
11. Early and mid-term functional and hemodynamic evaluation of the St. Jude Medical Regent 17 mm aortic valve mechanical prosthesis. Prifti E; Bonacchi M; Baboci A; Krakulli K; Giunti G J Heart Valve Dis; 2014 Jan; 23(1):112-21. PubMed ID: 24779337 [TBL] [Abstract][Full Text] [Related]
12. Assessment of the St. Jude Medical Regent prosthetic valve by continuous-wave Doppler and dobutamine stress echocardiography. Sezai A; Kasamaki Y; Abe K; Hata M; Sekino H; Shimura K; Minami K Ann Thorac Surg; 2010 Jan; 89(1):87-92. PubMed ID: 20103211 [TBL] [Abstract][Full Text] [Related]
13. Aortic valve replacement reduces valvuloarterial impedance but does not affect systemic arterial compliance in elderly men with degenerative calcific trileaflet aortic valve stenosis. Pagel PS; Schroeder AR; De Vry DJ; Hudetz JA J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1540-4. PubMed ID: 25267695 [TBL] [Abstract][Full Text] [Related]
14. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm). Kato Y; Hattori K; Motoki M; Takahashi Y; Kotani S; Nishimura S; Shibata T J Heart Valve Dis; 2013 Jul; 22(4):468-75. PubMed ID: 24224408 [TBL] [Abstract][Full Text] [Related]
15. [The evaluation of pressure gradients of various aortic valve prostheses by Doppler ultrasound and influence of pressure gradients to left ventricular function]. Aoki A Nihon Kyobu Geka Gakkai Zasshi; 1989 Apr; 37(4):676-87. PubMed ID: 2671194 [TBL] [Abstract][Full Text] [Related]
16. Cardiopulmonary exercise testing in patients with 21mm St. Jude Medical aortic prosthesis. De Carlo M; Milano A; Musumeci G; Tartarini G; Biadi O; Benedetti M; Bortolotti U J Heart Valve Dis; 1999 Sep; 8(5):522-8; discussion 528-9. PubMed ID: 10517394 [TBL] [Abstract][Full Text] [Related]
17. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis. Bleiziffer S; Eichinger WB; Wagner I; Guenzinger R; Bauernschmitt R; Lange R J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064 [TBL] [Abstract][Full Text] [Related]
18. [Effect of aortic valve replacement on left ventricular function in adult patients with aortic stenosis]. Goda T; Sasaki S; Go K; Matsui Y; Yasuda K; Tanabe T Nihon Kyobu Geka Gakkai Zasshi; 1992 Jun; 40(6):946-50. PubMed ID: 1634843 [TBL] [Abstract][Full Text] [Related]
19. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position. Jaffe WM; Coverdale HA; Roche AH; Whitlock RM; Neutze JM; Barratt-Boyes BG J Thorac Cardiovasc Surg; 1990 Aug; 100(2):167-74. PubMed ID: 2385114 [TBL] [Abstract][Full Text] [Related]
20. [The problem of 19 mm St. Jude Medical valve prosthesis in the small aortic annuls--19 mm St. Jude Medical valve vs 23 mm St. Jude Medical valve]. Yamanaka K; Ando F; Okamoto F; Hanada M; Sasahashi N; Hanada T; Nishigaki Y; Matsuno S Nihon Kyobu Geka Gakkai Zasshi; 1996 Jul; 44(7):906-11. PubMed ID: 8741548 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]