BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 21337418)

  • 1. Optimization of pulse train presaturation for CEST imaging in clinical scanners.
    Schmitt B; Zaiss M; Zhou J; Bachert P
    Magn Reson Med; 2011 Jun; 65(6):1620-9. PubMed ID: 21337418
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simulation, phantom validation, and clinical evaluation of fast pH-weighted molecular imaging using amine chemical exchange saturation transfer echo planar imaging (CEST-EPI) in glioma at 3 T.
    Harris RJ; Cloughesy TF; Liau LM; Nghiemphu PL; Lai A; Pope WB; Ellingson BM
    NMR Biomed; 2016 Nov; 29(11):1563-1576. PubMed ID: 27717216
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fast simulation and optimization of pulse-train chemical exchange saturation transfer (CEST) imaging.
    Xiao G; Sun PZ; Wu R
    Phys Med Biol; 2015 Jun; 60(12):4719-30. PubMed ID: 26020414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative pulsed CEST-MRI using Ω-plots.
    Meissner JE; Goerke S; Rerich E; Klika KD; Radbruch A; Ladd ME; Bachert P; Zaiss M
    NMR Biomed; 2015 Oct; 28(10):1196-208. PubMed ID: 26278686
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Understanding quantitative pulsed CEST in the presence of MT.
    Desmond KL; Stanisz GJ
    Magn Reson Med; 2012 Apr; 67(4):979-90. PubMed ID: 21858864
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variable delay multi-pulse train for fast chemical exchange saturation transfer and relayed-nuclear overhauser enhancement MRI.
    Xu J; Yadav NN; Bar-Shir A; Jones CK; Chan KW; Zhang J; Walczak P; McMahon MT; van Zijl PC
    Magn Reson Med; 2014 May; 71(5):1798-812. PubMed ID: 23813483
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T.
    Jones CK; Polders D; Hua J; Zhu H; Hoogduin HJ; Zhou J; Luijten P; van Zijl PC
    Magn Reson Med; 2012 Jun; 67(6):1579-89. PubMed ID: 22083645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low duty cycle pulse trains for exchange rate insensitive chemical exchange saturation transfer MRI.
    Chung JJ; Jin T
    Magn Reson Med; 2021 Nov; 86(5):2542-2551. PubMed ID: 34196028
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors affecting the chemical exchange saturation transfer of Creatine as assessed by 11.7 T MRI.
    Saito S; Mori Y; Tanki N; Yoshioka Y; Murase K
    Radiol Phys Technol; 2015 Jan; 8(1):146-52. PubMed ID: 25477238
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sidebands in CEST MR-How to recognize and avoid them.
    Schüre JR; Weinmüller S; Kamm L; Herz K; Zaiss M
    Magn Reson Med; 2024 Jun; 91(6):2391-2402. PubMed ID: 38317286
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved chemical exchange saturation transfer imaging with real-time frequency drift correction.
    Liu R; Zhang H; Niu W; Lai C; Ding Q; Chen W; Liang S; Zhou J; Wu D; Zhang Y
    Magn Reson Med; 2019 May; 81(5):2915-2923. PubMed ID: 30697813
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization of 7-T chemical exchange saturation transfer parameters for validation of glycosaminoglycan and amide proton transfer of fibroglandular breast tissue.
    Dula AN; Dewey BE; Arlinghaus LR; Williams JM; Klomp D; Yankeelov TE; Smith S
    Radiology; 2015 Apr; 275(1):255-61. PubMed ID: 25353249
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla.
    Martirosian P; Boss A; Deimling M; Kiefer B; Schraml C; Schwenzer NF; Claussen CD; Schick F
    Invest Radiol; 2008 Jan; 43(1):16-26. PubMed ID: 18097273
    [TBL] [Abstract][Full Text] [Related]  

  • 14. B1+ inhomogeneity mitigation in CEST using parallel transmission.
    Tse DHY; da Silva NA; Poser BA; Shah NJ
    Magn Reson Med; 2017 Dec; 78(6):2216-2225. PubMed ID: 28244138
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra.
    Zaiss M; Schmitt B; Bachert P
    J Magn Reson; 2011 Aug; 211(2):149-55. PubMed ID: 21641247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging.
    Wu R; Longo DL; Aime S; Sun PZ
    NMR Biomed; 2015 May; 28(5):555-65. PubMed ID: 25807919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of the saturation pulse duration on chemical exchange saturation transfer in amide proton transfer MR imaging: a phantom study.
    Wada T; Togao O; Tokunaga C; Funatsu R; Kobayashi K; Nakamura Y
    Radiol Phys Technol; 2016 Jan; 9(1):15-21. PubMed ID: 26099607
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fast fat suppression RF pulse train with insensitivity to B1 inhomogeneity for body imaging.
    Abe T
    Magn Reson Med; 2012 Feb; 67(2):464-9. PubMed ID: 21633968
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new contrast in MR mammography by means of chemical exchange saturation transfer (CEST) imaging at 3 Tesla: preliminary results.
    Schmitt B; Zamecnik P; Zaiss M; Rerich E; Schuster L; Bachert P; Schlemmer HP
    Rofo; 2011 Nov; 183(11):1030-6. PubMed ID: 22034086
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods.
    Zaiss M; Bachert P
    Phys Med Biol; 2013 Nov; 58(22):R221-69. PubMed ID: 24201125
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.