These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 21338409)

  • 1. Influence of probe application pressure on in vitro and in vivo capacitance (Corneometer CM 825(®)) and conductance (Skicon 200 EX(®)) measurements.
    Clarys P; Clijsen R; Barel AO
    Skin Res Technol; 2011 Nov; 17(4):445-50. PubMed ID: 21338409
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydration measurements of the stratum corneum: comparison between the capacitance method (digital version of the Corneometer CM 825®) and the impedance method (Skicon-200EX®).
    Clarys P; Clijsen R; Taeymans J; Barel AO
    Skin Res Technol; 2012 Aug; 18(3):316-23. PubMed ID: 22092664
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inter-instrumental variation of skin capacitance measured with the Corneometer.
    O'goshi K; Serup J
    Skin Res Technol; 2005 May; 11(2):107-9. PubMed ID: 15807808
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Skin conductance; validation of Skicon-200EX compared to the original model, Skicon-100.
    O'goshi K; Serup J
    Skin Res Technol; 2007 Feb; 13(1):13-8. PubMed ID: 17250527
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrical measurement of the water content of the stratum corneum in vivo and in vitro under various conditions: comparison between skin surface hygrometer and corneometer in evaluation of the skin surface hydration state.
    Hashimoto-Kumasaka K; Takahashi K; Tagami H
    Acta Derm Venereol; 1993 Oct; 73(5):335-9. PubMed ID: 7904396
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of skin moisture. Measurement of electrical conductance, capacitance and transepidermal water loss.
    Blichmann CW; Serup J
    Acta Derm Venereol; 1988; 68(4):284-90. PubMed ID: 2459872
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer.
    Alanen E; Nuutinen J; Nicklén K; Lahtinen T; Mönkkönen J
    Skin Res Technol; 2004 Feb; 10(1):32-7. PubMed ID: 14731246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro calibration of the capacitance method (Corneometer CM 825) and conductance method (Skicon-200) for the evaluation of the hydration state of the skin.
    Barel AO; Clarys P
    Skin Res Technol; 1997 May; 3(2):107-13. PubMed ID: 27333371
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Capacitance imaging of the skin surface.
    Batisse D; Giron F; Lévêque JL
    Skin Res Technol; 2006 May; 12(2):99-104. PubMed ID: 16626383
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Moisture Evaluator: a direct measure of fingertip skin hydration during object manipulation.
    André T; De Wan M; Lefèvre P; Thonnard JL
    Skin Res Technol; 2008 Nov; 14(4):385-9. PubMed ID: 18937771
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrating effects of moisturizer active compounds incorporated into hydrogels: in vivo assessment and comparison between devices.
    Leite e Silva VR; Schulman MA; Ferelli C; Gimenis JM; Ruas GW; Baby AR; Velasco MV; Taqueda ME; Kaneko TM
    J Cosmet Dermatol; 2009 Mar; 8(1):32-9. PubMed ID: 19250164
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Photoaging of the chest analyzed by capacitance imaging.
    Bazin R; Laquièze S; Rosillo A; Lévêque JL
    Skin Res Technol; 2010 Feb; 16(1):23-9. PubMed ID: 20384880
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Construction, in vitro and in vivo evaluation of an in-house conductance meter for measurement of skin hydration.
    Hamed SH; Altrabsheh B; Assa'd T; Jaradat S; Alshra'ah M; Aljamal A; Alkhatib HS; Almalty AM
    Med Eng Phys; 2012 Dec; 34(10):1471-6. PubMed ID: 22430060
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrical measurement of moisturizing effect on skin hydration and barrier function in psoriasis patients.
    Rim JH; Jo SJ; Park JY; Park BD; Youn JI
    Clin Exp Dermatol; 2005 Jul; 30(4):409-13. PubMed ID: 15953083
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comprehensive comparison of facial skin hydration based on capacitance and conductance measurements in Chinese women.
    Voegeli R; Cherel M; Schoop R; Rawlings AV
    Int J Cosmet Sci; 2022 Dec; 44(6):703-718. PubMed ID: 35980652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Skin capacitance imaging of acne lesions.
    Xhauflaire-Uhoda E; Piérard GE
    Skin Res Technol; 2007 Feb; 13(1):9-12. PubMed ID: 17250526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Understanding effects of topical ingredients on electrical measurement of skin hydration.
    Crowther JM
    Int J Cosmet Sci; 2016 Dec; 38(6):589-598. PubMed ID: 27028308
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of 3 moisturisers on skin surface hydration: Electrical conductance (Skicon-200), capacitance (Corneometer CM420), and transepidermal water loss (TEWL).
    Møss J
    Skin Res Technol; 1996 Feb; 2(1):32-6. PubMed ID: 27327056
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of a single application of different moisturizers on the skin capacitance.
    Lodén M; Lindberg M
    Acta Derm Venereol; 1991; 71(1):79-82. PubMed ID: 1676227
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measuring the effects of topical moisturizers on changes in stratum corneum thickness, water gradients and hydration in vivo.
    Crowther JM; Sieg A; Blenkiron P; Marcott C; Matts PJ; Kaczvinsky JR; Rawlings AV
    Br J Dermatol; 2008 Sep; 159(3):567-77. PubMed ID: 18616783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.