These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 21339482)

  • 1. Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative).
    Khawaja MZ; Rajani R; Cook A; Khavandi A; Moynagh A; Chowdhary S; Spence MS; Brown S; Khan SQ; Walker N; Trivedi U; Hutchinson N; De Belder AJ; Moat N; Blackman DJ; Levy RD; Manoharan G; Roberts D; Khogali SS; Crean P; Brecker SJ; Baumbach A; Mullen M; Laborde JC; Hildick-Smith D
    Circulation; 2011 Mar; 123(9):951-60. PubMed ID: 21339482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis.
    Jilaihawi H; Chin D; Vasa-Nicotera M; Jeilan M; Spyt T; Ng GA; Bence J; Logtens E; Kovac J
    Am Heart J; 2009 May; 157(5):860-6. PubMed ID: 19376312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
    Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.
    Petronio AS; Sinning JM; Van Mieghem N; Zucchelli G; Nickenig G; Bekeredjian R; Bosmans J; Bedogni F; Branny M; Stangl K; Kovac J; Schiltgen M; Kraus S; de Jaegere P
    JACC Cardiovasc Interv; 2015 May; 8(6):837-846. PubMed ID: 25999108
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Factors predicting and having an impact on the need for a permanent pacemaker after CoreValve prosthesis implantation using the new Accutrak delivery catheter system.
    Muñoz-García AJ; Hernández-García JM; Jiménez-Navarro MF; Alonso-Briales JH; Domínguez-Franco AJ; Fernández-Pastor J; Peña Hernández J; Barrera Cordero A; Alzueta Rodríguez J; de Teresa-Galván E
    JACC Cardiovasc Interv; 2012 May; 5(5):533-539. PubMed ID: 22625192
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.
    van der Boon RM; Van Mieghem NM; Theuns DA; Nuis RJ; Nauta ST; Serruys PW; Jordaens L; van Domburg RT; de Jaegere PP
    Int J Cardiol; 2013 Sep; 168(2):1269-73. PubMed ID: 23295037
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incidence, indications and predicting factors of permanent pacemaker implantation after transcatheter aortic valve implantation: A retrospective study.
    Becker M; Blangy H; Folliguet T; Villemin T; Freysz L; Luc A; Maureira P; Popovic B; Olivier A; Sadoul N
    Arch Cardiovasc Dis; 2017 Oct; 110(10):508-516. PubMed ID: 28647466
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Postoperative permanent pacemaker implantation in patients undergoing trans-catheter aortic valve implantation: what is the incidence and are there any predicting factors?
    Bates MG; Matthews IG; Fazal IA; Turley AJ
    Interact Cardiovasc Thorac Surg; 2011 Feb; 12(2):243-53. PubMed ID: 21098508
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation.
    De Carlo M; Giannini C; Bedogni F; Klugmann S; Brambilla N; De Marco F; Zucchelli G; Testa L; Oreglia J; Petronio AS
    Am Heart J; 2012 Mar; 163(3):492-9. PubMed ID: 22424022
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve Revalving System.
    Guetta V; Goldenberg G; Segev A; Dvir D; Kornowski R; Finckelstein A; Hay I; Goldenberg I; Glikson M
    Am J Cardiol; 2011 Dec; 108(11):1600-5. PubMed ID: 21880290
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis.
    Ferreira ND; Caeiro D; Adão L; Oliveira M; Gonçalves H; Ribeiro J; Teixeira M; Albuquerque A; Primo J; Braga P; Simões L; Ribeiro VG
    Pacing Clin Electrophysiol; 2010 Nov; 33(11):1364-72. PubMed ID: 20723083
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion.
    Al-Azzam F; Greason KL; Krittanawong C; Williamson EE; McLeod CJ; King KS; Mathew V
    J Thorac Cardiovasc Surg; 2017 May; 153(5):1056-1062.e1. PubMed ID: 28073567
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors of permanent pacemaker requirement after transcatheter aortic valve implantation: insights from a Brazilian registry.
    Gensas CS; Caixeta A; Siqueira D; Carvalho LA; Sarmento-Leite R; Mangione JA; Lemos PA; Colafranceschi AS; Caramori P; Ferreira MC; Abizaid A; Brito FS;
    Int J Cardiol; 2014 Aug; 175(2):248-52. PubMed ID: 24880480
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.
    Kaneko H; Hoelschermann F; Seifert M; Tambor G; Okamoto M; Moeller V; Neuss M; Butter C
    Heart Vessels; 2019 Feb; 34(2):360-367. PubMed ID: 30083944
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The incidence of transcatheter aortic valve implantation-related heart block in self-expandable Medtronic CoreValve and balloon-expandable Edwards valves.
    Liang M; Devlin G; Pasupati S
    J Invasive Cardiol; 2012 Apr; 24(4):173-6. PubMed ID: 22477754
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.
    Hamdan A; Guetta V; Klempfner R; Konen E; Raanani E; Glikson M; Goitein O; Segev A; Barbash I; Fefer P; Spiegelstein D; Goldenberg I; Schwammenthal E
    JACC Cardiovasc Interv; 2015 Aug; 8(9):1218-1228. PubMed ID: 26292585
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.