130 related articles for article (PubMed ID: 21340180)
1. Hyperprolactinemia: new assay more specific for the monomeric form does not eliminate screening for macroprolactin with polyethylene glycol precipitation.
Vieira JG; Tachibana TT; Ferrer CM; Sá Jd; Biscolla RP; Hoff AO; Kanashiro I
Arq Bras Endocrinol Metabol; 2010 Dec; 54(9):856-7. PubMed ID: 21340180
[No Abstract] [Full Text] [Related]
2. Serum prolactin revisited: parametric reference intervals and cross platform evaluation of polyethylene glycol precipitation-based methods for discrimination between hyperprolactinemia and macroprolactinemia.
Overgaard M; Pedersen SM
Clin Chem Lab Med; 2017 Oct; 55(11):1744-1753. PubMed ID: 28236625
[TBL] [Abstract][Full Text] [Related]
3. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(5-6):301-7. PubMed ID: 17605405
[TBL] [Abstract][Full Text] [Related]
4. Macroprolactinemia Detection by Magnetically Assisted Polyethylene Glycol Precipitation: Potential for Automation.
Smith T; Stern E; Tan E; Vacic A; Fahie-Wilson M
J Appl Lab Med; 2020 May; 5(3):494-505. PubMed ID: 32445359
[TBL] [Abstract][Full Text] [Related]
5. Macroprolactin detection by precipitation with protein A-sepharose: a rapid screening method compared with polyethylene glycol precipitation.
Sapin R; Kertesz G
Clin Chem; 2003 Mar; 49(3):502-5. PubMed ID: 12600967
[No Abstract] [Full Text] [Related]
6. A New Method of Using Polyethylene Glycol (PEG) Precipitation of Macroprolactin to Detect Genuine Hyperprolactinemia.
Chen Y; Wang H; Yang W; Jin W; Yu W; Wang W; Zhang K; Song G
J Clin Lab Anal; 2016 Nov; 30(6):1169-1174. PubMed ID: 27219457
[TBL] [Abstract][Full Text] [Related]
7. Prolactin and macroprolactin: a case report of hyperprolactinaemia highlighting the interpretation of discrepant results.
Ismail AA; Walker PL; Fahie-Wilson MN; Jassam N; Barth JH
Ann Clin Biochem; 2003 May; 40(Pt 3):298-300. PubMed ID: 12803849
[TBL] [Abstract][Full Text] [Related]
8. Comparison of multiple methods for identification of hyperprolactinemia in the presence of macroprolactin.
McCudden CR; Sharpless JL; Grenache DG
Clin Chim Acta; 2010 Feb; 411(3-4):155-60. PubMed ID: 19895797
[TBL] [Abstract][Full Text] [Related]
9. False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins.
Ram S; Harris B; Fernando JJ; Gama R; Fahie-Wilson M
Ann Clin Biochem; 2008 May; 45(Pt 3):256-9. PubMed ID: 18482912
[TBL] [Abstract][Full Text] [Related]
10. Assessment of intraindividual agreement in prolactin results after post-polyethylene glycol precipitation test for the estimation of macroprolactin. Should the precipitation procedure be repeated in the same patient?
Jimenez-Anon L; Barallat J; Regidor D; Urgell E; Dolade M; Granada ML
Clin Chem Lab Med; 2020 Aug; 59(1):e27-e29. PubMed ID: 32739904
[No Abstract] [Full Text] [Related]
11. [Usefulness of Polyethylene-Glycol Precipitation As a Screening Method for Macroprolactinemia].
Yamakami A; Takahashi R; Fukazawa C; Tanaka C; Takeda K
Rinsho Byori; 2016 Sep; 64(9):1012-1015. PubMed ID: 30609453
[TBL] [Abstract][Full Text] [Related]
12. Determination of prolactin: the macroprolactin problem.
Fahie-Wilson M; Smith TP
Best Pract Res Clin Endocrinol Metab; 2013 Oct; 27(5):725-42. PubMed ID: 24094642
[TBL] [Abstract][Full Text] [Related]
13. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.
Whitehead SJ; Cornes MP; Ford C; Gama R
Ann Clin Biochem; 2015 Jan; 52(Pt 1):61-6. PubMed ID: 25074991
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of monomeric prolactin level by TRACE method and precipitation with polyethylene glycol.
Vorotnikova SY; Dzeranova LK; Fedorova NS; Pigarova EA; Vershinina MG; Il'in AV
Klin Lab Diagn; 2021 Mar; 66(2):69-74. PubMed ID: 33734638
[TBL] [Abstract][Full Text] [Related]
15. Comparison of PEG precipitation and ultrafiltration treatment for serum macroprolactin in Chinese patients with hyperprolactinemia.
Ke X; Wang L; Duan L; Yang H; Yin J; Qiu L; Pan H; Gong F; Zhu H
Clin Chim Acta; 2023 Apr; 544():117358. PubMed ID: 37086942
[TBL] [Abstract][Full Text] [Related]
16. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(7-8):485-92. PubMed ID: 17821956
[TBL] [Abstract][Full Text] [Related]
17. Importance of screening for macroprolactin in all hyperprolactinaemic sera.
Jamaluddin FA; Sthaneshwar P; Hussein Z; Othman N; Chan SP
Malays J Pathol; 2013 Jun; 35(1):59-63. PubMed ID: 23817395
[TBL] [Abstract][Full Text] [Related]
18. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin.
Byrne B; O'Shea P; Barrett P; Tormey W
Clin Chem Lab Med; 2010 Feb; 48(2):205-8. PubMed ID: 19943807
[TBL] [Abstract][Full Text] [Related]
19. Macroprolactin and the Roche Elecsys prolactin assay: characteristics of the reaction and detection by precipitation with polyethylene glycol.
Fahie-Wilson M; Brunsden P; Surrey J; Everitt A
Clin Chem; 2000 Dec; 46(12):1993-5. PubMed ID: 11106334
[No Abstract] [Full Text] [Related]
20. [Macroprolactin detection: a new approach].
Sapin R; Gasser F; Fischbach E; Grucker D
Ann Biol Clin (Paris); 2000; 58(6):729-34. PubMed ID: 11098170
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]