These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 21342020)

  • 1. Indirect reference intervals of plasma and serum thyrotropin (TSH) concentrations from intra-laboratory data bases from several German and Italian medical centres.
    Arzideh F; Wosniok W; Haeckel R
    Clin Chem Lab Med; 2011 Apr; 49(4):659-64. PubMed ID: 21342020
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reference limits of plasma and serum creatinine concentrations from intra-laboratory data bases of several German and Italian medical centres: Comparison between direct and indirect procedures.
    Arzideh F; Wosniok W; Haeckel R
    Clin Chim Acta; 2010 Feb; 411(3-4):215-21. PubMed ID: 19914230
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A plea for intra-laboratory reference limits. Part 2. A bimodal retrospective concept for determining reference limits from intra-laboratory databases demonstrated by catalytic activity concentrations of enzymes.
    Arzideh F; Wosniok W; Gurr E; Hinsch W; Schumann G; Weinstock N; Haeckel R
    Clin Chem Lab Med; 2007; 45(8):1043-57. PubMed ID: 17867994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reference range for thyrotropin. Post hoc assessment.
    Larisch R; Giacobino A; Eckl W; Wahl HG; Midgley JE; Hoermann R
    Nuklearmedizin; 2015; 54(3):112-7. PubMed ID: 25567792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Age-specific thyroid hormone and thyrotropin reference intervals for a pediatric and adolescent population.
    Chaler EA; Fiorenzano R; Chilelli C; Llinares V; Areny G; Herzovich V; Maceiras M; Lazzati JM; Mendioroz M; Rivarola MA; Belgorosky A
    Clin Chem Lab Med; 2012 Apr; 50(5):885-90. PubMed ID: 22628332
    [TBL] [Abstract][Full Text] [Related]  

  • 6. TSH continuous reference intervals by indirect methods: A Comparisons to Partitioned Reference Intervals.
    Mokhtar KM
    Clin Biochem; 2020 Nov; 85():53-56. PubMed ID: 32795473
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.
    Schalin-Jäntti C; Tanner P; Välimäki MJ; Hämäläinen E
    Scand J Clin Lab Invest; 2011 Jul; 71(4):344-9. PubMed ID: 21426266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of total patient data for indirect estimation of reference intervals for 40 clinical chemical analytes in Turkey.
    Ilcol YO; Aslan D
    Clin Chem Lab Med; 2006; 44(7):867-76. PubMed ID: 16776635
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A multicenter study for the evaluation of the reference interval for TSH in Italy (ELAS TSH Italian Study).
    Clerico A; Trenti T; Aloe R; Dittadi R; Rizzardi S; Migliardi M; Musa R; Dipalo M; Prontera C; Masotti S; Musetti V; Tozzoli R; Padoan A; Bagnasco M;
    Clin Chem Lab Med; 2018 Dec; 57(2):259-267. PubMed ID: 30016276
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biological variables influencing the estimation of reference limits.
    Özçürümez MK; Haeckel R
    Scand J Clin Lab Invest; 2018 Sep; 78(5):337-345. PubMed ID: 29764232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Indirect estimation of age-related reference limits of thyroid parameters: a cross-sectional study of outpatients' results.
    Milinković N; Ignjatović S; Žarković M; Jovičić S; Radosavljević B; Singh S; Majkić-Singh N
    Scand J Clin Lab Invest; 2014 Aug; 74(5):378-84. PubMed ID: 24684474
    [TBL] [Abstract][Full Text] [Related]  

  • 12. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.
    Adeli K; Higgins V; Seccombe D; Collier CP; Balion CM; Cembrowski G; Venner AA; Shaw J;
    Clin Biochem; 2017 Nov; 50(16-17):925-935. PubMed ID: 28647526
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Utility of a panel of sera for the alignment of test results in the worldwide multicenter study on reference values.
    Ichihara K; Ozarda Y; Klee G; Straseski J; Baumann N; Ishikura K;
    Clin Chem Lab Med; 2013 May; 51(5):1007-25. PubMed ID: 23633468
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thyroid hormone reference intervals in an ambulatory Arab population on the Abbott Architect i2000 immunoassay analyzer.
    Dhatt GS; Griffin G; Agarwal MM
    Clin Chim Acta; 2006 Feb; 364(1-2):226-9. PubMed ID: 16098499
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Standardization of the methods of lipid determination according to WHO in the regional project of prevention of cardiovascular diseases in Friuli-Venezia Giulia].
    Grafnetter D; Feruglio GA; Vanuzzo D
    G Ital Cardiol; 1996 Mar; 26(3):287-97. PubMed ID: 8690184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Italian cancer figures, report 2012: Cancer in children and adolescents.
    ; ;
    Epidemiol Prev; 2013; 37(1 Suppl 1):1-225. PubMed ID: 23585445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study.
    Ceriotti F; Henny J; Queraltó J; Ziyu S; Özarda Y; Chen B; Boyd JC; Panteghini M; ;
    Clin Chem Lab Med; 2010 Nov; 48(11):1593-601. PubMed ID: 21034260
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The mean platelet volume is positively correlated with serum thyrotropin concentrations in a population of healthy subjects and subjects with unsuspected subclinical hypothyroidism.
    Kim JH; Park JH; Kim SY; Bae HY
    Thyroid; 2013 Jan; 23(1):31-7. PubMed ID: 22966899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Harmonization protocols for TSH immunoassays: a multicenter study in Italy.
    Clerico A; Ripoli A; Fortunato A; Alfano A; Carrozza C; Correale M; Dittadi R; Gessoni G; Migliardi M; Rizzardi S; Prontera C; Masotti S; Zucchelli G; Guiotto C; Iacovazzi PA; Iervasi G;
    Clin Chem Lab Med; 2017 Oct; 55(11):1722-1733. PubMed ID: 28245185
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A reference interval study for common biochemical analytes in Eastern Turkey: a comparison of a reference population with laboratory data mining.
    Bakan E; Polat H; Ozarda Y; Ozturk N; Baygutalp NK; Umudum FZ; Bakan N
    Biochem Med (Zagreb); 2016; 26(2):210-23. PubMed ID: 27346966
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.