BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

498 related articles for article (PubMed ID: 21342822)

  • 1. Monitoring of thermal therapy based on shear modulus changes: I. shear wave thermometry.
    Arnal B; Pernot M; Tanter M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):369-78. PubMed ID: 21342822
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monitoring of thermal therapy based on shear modulus changes: II. Shear wave imaging of thermal lesions.
    Arnal B; Pernot M; Tanter M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Aug; 58(8):1603-11. PubMed ID: 21859579
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
    Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
    Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring MR-guided high intensity focused ultrasound therapy using transient supersonic shear wave MR-elastography.
    Ishak O; Breton E; Choquet K; Josset A; Cabras P; Vappou J
    Phys Med Biol; 2023 Jan; 68(3):. PubMed ID: 36595333
    [No Abstract]   [Full Text] [Related]  

  • 5. Cardiac shear-wave elastography using a transesophageal transducer: application to the mapping of thermal lesions in ultrasound transesophageal cardiac ablation.
    Kwiecinski W; Bessière F; Colas EC; N'Djin WA; Tanter M; Lafon C; Pernot M
    Phys Med Biol; 2015 Oct; 60(20):7829-46. PubMed ID: 26406354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.
    Celicanin Z; Auboiroux V; Bieri O; Petrusca L; Santini F; Viallon M; Scheffler K; Salomir R
    Magn Reson Med; 2014 Oct; 72(4):1087-95. PubMed ID: 24243500
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU).
    Grondin J; Payen T; Wang S; Konofagou EE
    J Vis Exp; 2015 Nov; (105):e53050. PubMed ID: 26556647
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
    Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT
    NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reference-free PRFS MR-thermometry using near-harmonic 2-D reconstruction of the background phase.
    Salomir R; Viallon M; Kickhefel A; Roland J; Morel DR; Petrusca L; Auboiroux V; Goget T; Terraz S; Becker CD; Gross P
    IEEE Trans Med Imaging; 2012 Feb; 31(2):287-301. PubMed ID: 21937345
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time monitoring of high-intensity focused ultrasound treatment using axial strain and axial-shear strain elastograms.
    Xia R; Thittai AK
    Ultrasound Med Biol; 2014 Mar; 40(3):485-95. PubMed ID: 24361216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatio-temporal quantitative thermography of pre-focal interactions between high intensity focused ultrasound and the rib cage.
    Petrusca L; Salomir R; Manasseh G; Becker CD; Terraz S
    Int J Hyperthermia; 2015 Jun; 31(4):421-32. PubMed ID: 25753370
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo T2 -based MR thermometry in adipose tissue layers for high-intensity focused ultrasound near-field monitoring.
    Baron P; Ries M; Deckers R; de Greef M; Tanttu J; Köhler M; Viergever MA; Moonen CT; Bartels LW
    Magn Reson Med; 2014 Oct; 72(4):1057-64. PubMed ID: 24259459
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.
    Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ
    Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring thermally-induced lesions with supersonic shear imaging.
    Bercoff J; Pernot M; Tanter M; Fink M
    Ultrason Imaging; 2004 Apr; 26(2):71-84. PubMed ID: 15344412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Viscoelastic characterization of HIFU ablation with shear wave by using K-space analysis combined with model-fitting correction method.
    Wang X; Geng Y; Han D; Lu M; Li R; Li Y; Zhang Q; Wan M
    Ultrasonics; 2020 Dec; 108():106179. PubMed ID: 32504988
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laser-induced fluorescence thermometry of heating in water from short bursts of high intensity focused ultrasound.
    Al-Qraini MM; Canney MS; Oweis GF
    Ultrasound Med Biol; 2013 Apr; 39(4):647-59. PubMed ID: 23497843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.
    Celicanin Z; Manasseh G; Petrusca L; Scheffler K; Auboiroux V; Crowe LA; Hyacinthe JN; Natsuaki Y; Santini F; Becker CD; Terraz S; Bieri O; Salomir R
    Magn Reson Med; 2018 May; 79(5):2511-2523. PubMed ID: 28944490
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: In vivo Young's modulus mapping of pancreatic ductal adenocarcinoma during HIFU ablation using harmonic motion elastography (HME).
    Nabavizadeh A; Payen T; Saharkhiz N; McGarry M; Olive KP; Konofagou EE
    Med Phys; 2018 Nov; 45(11):5244-5250. PubMed ID: 30178474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.