These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

338 related articles for article (PubMed ID: 21345158)

  • 1. A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-art.
    Haeckel R; Wosniok W
    Clin Chem Lab Med; 2011 Apr; 49(4):623-35. PubMed ID: 21345158
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reprint of "Influence of analytical bias and imprecision on the number of false positive results using Guideline-Driven Medical Decision Limits".
    Hyltoft Petersen P; Klee GG
    Clin Chim Acta; 2014 May; 432():127-34. PubMed ID: 24747109
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Do new concepts for deriving permissible limits for analytical imprecision and bias have any advantages over existing consensus?
    Petersen PH; Sandberg S; Fraser CG
    Clin Chem Lab Med; 2011 Apr; 49(4):637-40. PubMed ID: 21345044
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A pragmatic proposal for permissible limits in external quality assessment schemes with a compromise between biological variation and the state of the art.
    Haeckel R; Wosniok W; Kratochvila J; Carobene A
    Clin Chem Lab Med; 2012 Jan; 50(5):833-9. PubMed ID: 22628326
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Permissible limits for uncertainty of measurement in laboratory medicine.
    Haeckel R; Wosniok W; Gurr E; Peil B
    Clin Chem Lab Med; 2015 Jul; 53(8):1161-71. PubMed ID: 25720082
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing the use of the "state-of-the-art" performance criteria.
    Haeckel R; Wosniok W; Streichert T
    Clin Chem Lab Med; 2015 May; 53(6):887-91. PubMed ID: 25803083
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination of analytical quality specifications based on biological within- and between-subject variation.
    Petersen PH; Fraser CG; Jørgensen L; Brandslund I; Stahl M; Gowans E; Libeer JC; Ricós C
    Ann Clin Biochem; 2002 Nov; 39(Pt 6):543-50. PubMed ID: 12564835
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of analytical bias and imprecision on the number of false positive results using Guideline-Driven Medical Decision Limits.
    Hyltoft Petersen P; Klee GG
    Clin Chim Acta; 2014 Mar; 430():1-8. PubMed ID: 24362233
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The discordance rate, a new concept for combining diagnostic decisions with analytical performance characteristics. 2. Defining analytical goals applied to the diagnosis of type 2 diabetes by blood glucose concentrations.
    Haeckel R; Wosniok W
    Clin Chem Lab Med; 2004 Feb; 42(2):198-203. PubMed ID: 15061361
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of analytical bias on diagnostic misclassifications.
    Petersen PH; de Verdier CH; Groth T; Fraser CG; Blaabjerg O; Hørder M
    Clin Chim Acta; 1997 Apr; 260(2):189-206. PubMed ID: 9177913
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Discordance rate, a new concept for combining diagnostic decisions with analytical performance characteristics. 1. Application in method or sample system comparisons and in defining decision limits.
    Haeckel R; Wosniok W; Puentmann I
    Clin Chem Lab Med; 2003 Mar; 41(3):347-55. PubMed ID: 12705345
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A simple matrix of analytical performance to identify assays that risk patients using External Quality Assurance Program data.
    Mackay M; Hegedus G; Badrick T
    Clin Biochem; 2016 May; 49(7-8):596-600. PubMed ID: 26800780
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measuring Analytical Quality: Total Analytical Error Versus Measurement Uncertainty.
    Westgard JO; Westgard SA
    Clin Lab Med; 2017 Mar; 37(1):1-13. PubMed ID: 28153359
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Requirements for reproducibility, trueness and error of measurement in internal quality control schemes.
    Bonvicini P; Metus P; Pavón MA; Tocchini M
    Clin Chem Lab Med; 2003 May; 41(5):693-9. PubMed ID: 12812269
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Proposal for the modification of the conventional model for establishing performance specifications.
    Oosterhuis WP; Sandberg S
    Clin Chem Lab Med; 2015 May; 53(6):925-37. PubMed ID: 25901717
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance goals for the laboratory testing of antithrombin, protein C and protein S.
    Meijer P; Haverkate F; Kluft C
    Thromb Haemost; 2006 Nov; 96(5):584-9. PubMed ID: 17080214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical goals for quantities used to assess thyrometabolic status.
    Browning MC
    Ann Clin Biochem; 1989 Jan; 26 ( Pt 1)():1-12. PubMed ID: 2660738
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Expressing analytical performance from multi-sample evaluation in laboratory EQA.
    Thelen MHM; Jansen RTP; Weykamp CW; Steigstra H; Meijer R; Cobbaert CM
    Clin Chem Lab Med; 2017 Aug; 55(10):1509-1516. PubMed ID: 28182577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity.
    Klee GG
    Clin Chem; 1993 Jul; 39(7):1514-8. PubMed ID: 8330413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analytical goals for coagulation tests based on biological variation.
    Wada Y; Kurihara M; Toyofuku M; Kawamura M; Iida H; Kayamori Y; Kinoshita S; Hamasaki N
    Clin Chem Lab Med; 2004 Jan; 42(1):79-83. PubMed ID: 15061385
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.