These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 2134913)

  • 1. [Analysis of the denture dynamics in R.P.D.'s. 2. Influence of retainers on the dynamics of free-end-saddle].
    Igarashi Y; Kawata M; Asami M; Shiba A
    Nihon Hotetsu Shika Gakkai Zasshi; 1990 Feb; 34(1):128-35. PubMed ID: 2134913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stress distribution and abutment tooth mobility of distal-extension removable partial dentures with different retainers: an in vivo study.
    Igarashi Y; Ogata A; Kuroiwa A; Wang CH
    J Oral Rehabil; 1999 Feb; 26(2):111-6. PubMed ID: 10080307
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An analysis of stress distribution in the free-end saddles on the mandibular model.
    Shibuya T
    Bull Tokyo Med Dent Univ; 1975 Sep; 22(3):221-34. PubMed ID: 776432
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Analysis of the denture dynamics in R.P.D.'s. 1. Methods for analyzing the denture dynamics of free-end-saddle].
    Igarashi Y
    Nihon Hotetsu Shika Gakkai Zasshi; 1989 Apr; 33(2):369-75. PubMed ID: 2489571
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Stress analysis of abutment teeth on removal moment of R.P.D.'s].
    Hachikawa M
    Nihon Hotetsu Shika Gakkai Zasshi; 1990 Jun; 34(3):427-37. PubMed ID: 2135305
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of retainer and major connector designs of removable partial dentures on the stabilization of mobile teeth: A preliminary study.
    Nagayama T; Wada J; Watanabe C; Murakami N; Takakusaki K; Uchida H; Utsumi M; Wakabayashi N
    Dent Mater J; 2020 Jan; 39(1):89-100. PubMed ID: 31582595
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of loading locations and direct retainers on the movements of the abutment tooth and denture base of removable partial dentures.
    Mizuuchi W; Yatabe M; Sato M; Nishiyama A; Ohyama T
    J Med Dent Sci; 2002 Mar; 49(1):11-8. PubMed ID: 12160222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of partial denture design on abutment tooth and saddle movement.
    Feingold GM; Grant AA; Johnson W
    J Oral Rehabil; 1986 Nov; 13(6):549-57. PubMed ID: 3540241
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of direct retainer and major connector designs on RPD and abutment tooth movement dynamics.
    Itoh H; Baba K; Aridome K; Okada D; Tokuda A; Nishiyama A; Miura H; Igarashi Y
    J Oral Rehabil; 2008 Nov; 35(11):810-5. PubMed ID: 18482346
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Selection of retainers in lower overlay denture-in relation to the abutment tooth mobility--(a laboratory study).
    Igarashi Y
    Bull Tokyo Med Dent Univ; 1975 Sep; 22(3):207-20. PubMed ID: 776431
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.
    Kim D; Park C; Yi Y; Cho L
    J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laboratory study on abutment movement of the combined clasp, the extension clasp and the telescopic crown.
    Han D; Liu L; Li Q; Li B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2002 Sep; 37(5):349-52. PubMed ID: 12425846
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanics of removable partial denture design-wrought wire and the extension base removable partial denture.
    Rommerdale EH; Akerly WB
    Trends Tech Contemp Dent Lab; 1991 Mar; 8(2):45-9. PubMed ID: 1947638
    [No Abstract]   [Full Text] [Related]  

  • 14. Occlusion of artificial teeth in partial dentures in the "chewing center"--first exploratory population-based evaluations.
    Kordass B; Ruge S; Quooss A; Hugger A; Mundt T
    Int J Comput Dent; 2014; 17(3):185-95. PubMed ID: 25558759
    [TBL] [Abstract][Full Text] [Related]  

  • 15. When to choose which retention element to use for removable dental prostheses.
    Zitzmann NU; Rohner U; Weiger R; Krastl G
    Int J Prosthodont; 2009; 22(2):161-7. PubMed ID: 19418863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Designing clasps for the asymmetric distal extension removable partial denture.
    Ben-Ur Z; Gorfil C; Shifman A
    Int J Prosthodont; 1996; 9(4):374-8. PubMed ID: 8957876
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention for a removable partial denture.
    Johnson DL
    J Prosthodont; 1992 Sep; 1(1):11-7. PubMed ID: 1308213
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Kinetics and load distribution of supported free-end prostheses. IV. Effect of the saddle curvature on the saddle resp. abutment kinetics and the load distribution in prosthesis beds without abutments].
    Ludwig P; Rarisch B
    Dtsch Zahnarztl Z; 1979 Mar; 34(3):251-6. PubMed ID: 374045
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preparation of composite retentive areas for removable partial denture retainers.
    Pavarina AC; Machado AL; Vergani CE; Giampaolo ET
    J Prosthet Dent; 2002 Aug; 88(2):218-20. PubMed ID: 12397251
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photoelastic study of the support structures of distal-extension removable partial dentures.
    Costa MM; da Silva MA; Oliveira SA; Gomes VL; Carvalho PM; Lucas BL
    J Prosthodont; 2009 Oct; 18(7):589-95. PubMed ID: 19531158
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.