These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 2135501)

  • 1. [Study on method for examining bone quality for dental implant. Relationship between cutting force and bone mineral content].
    Sugaya K
    Shikwa Gakuho; 1990 Apr; 90(4):607-33. PubMed ID: 2135501
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
    Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
    Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets.
    Cehreli MC; Kökat AM; Comert A; Akkocaoğlu M; Tekdemir I; Akça K
    Clin Oral Implants Res; 2009 Oct; 20(10):1163-9. PubMed ID: 19681964
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
    Tabassum A; Meijer GJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative evaluation of the peri-implant bone tissue mineral density around unloaded titanium dental implants.
    Traini T; Degidi M; Iezzi G; Artese L; Piattelli A
    J Dent; 2007 Jan; 35(1):84-92. PubMed ID: 16979279
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Immediate loading of single SLA implants: drilling vs. osteotomes for the preparation of the implant site.
    Stavropoulos A; Nyengaard JR; Lang NP; Karring T
    Clin Oral Implants Res; 2008 Jan; 19(1):55-65. PubMed ID: 17956566
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs.
    Salmória KK; Tanaka OM; Guariza-Filho O; Camargo ES; de Souza LT; Maruo H
    Am J Orthod Dentofacial Orthop; 2008 Jun; 133(6):790.e15-22. PubMed ID: 18538236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Human ex vivo bone tissue strains around immediately-loaded implants supporting mandibular fixed prostheses.
    Kökat AM; Cömert A; Tekdemir I; Akkocaoğlu M; Akça K; Cehreli MC
    Implant Dent; 2009 Apr; 18(2):162-71. PubMed ID: 19359867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
    Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rehabilitation of edentulous mandibles by means of five TiUnite implants after one-stage surgery: a 1-year retrospective study of 90 patients.
    Friberg B; Jemt T
    Clin Implant Dent Relat Res; 2008 Mar; 10(1):47-54. PubMed ID: 18254740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers.
    Akça K; Akkocaoglu M; Cömert A; Tekdemir I; Cehreli MC
    Int J Oral Maxillofac Implants; 2007; 22(1):101-9. PubMed ID: 17340903
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of mechanical and thermal fatigue on dental drill performance.
    Harris BH; Kohles SS
    Int J Oral Maxillofac Implants; 2001; 16(6):819-26. PubMed ID: 11769832
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants.
    Degidi M; Perrotti V; Strocchi R; Piattelli A; Iezzi G
    Clin Oral Implants Res; 2009 Aug; 20(8):778-81. PubMed ID: 19486080
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment.
    Alsaadi G; Quirynen M; Michiels K; Jacobs R; van Steenberghe D
    J Clin Periodontol; 2007 Apr; 34(4):359-66. PubMed ID: 17378890
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
    Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
    Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of surgical techniques on primary implant stability and peri-implant bone.
    Fanuscu MI; Chang TL; Akça K
    J Oral Maxillofac Surg; 2007 Dec; 65(12):2487-91. PubMed ID: 18022474
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implant micromotion is related to peak insertion torque and bone density.
    Trisi P; Perfetti G; Baldoni E; Berardi D; Colagiovanni M; Scogna G
    Clin Oral Implants Res; 2009 May; 20(5):467-71. PubMed ID: 19522976
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs.
    Chen Y; Shin HI; Kyung HM
    Am J Orthod Dentofacial Orthop; 2008 Jan; 133(1):44-50. PubMed ID: 18174070
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resonance frequency analysis measurements of implants at placement surgery.
    Ostman PO; Hellman M; Wendelhag I; Sennerby L
    Int J Prosthodont; 2006; 19(1):77-83; discussion 84. PubMed ID: 16479765
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro validation of a novel diagnostic device for intraoperative determination of alveolar bone quality.
    Krafft T; Winter W; Wichmann M; Karl M
    Int J Oral Maxillofac Implants; 2012; 27(2):318-28. PubMed ID: 22442770
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.