BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 21359611)

  • 21. Measurement of the Tumor-to-Normal Ratio for Radioembolization of Hepatocellular Carcinoma: A Prospective Study Comparing 2-Dimensional Perfusion Angiography, Technetium-99m Macroaggregated Albumin, and Yttrium-90 SPECT/CT.
    Brunson CP; McGregor HJ; Hennemeyer CT; Patel MV; Woodhead GJ; Young SJ
    J Vasc Interv Radiol; 2024 Jan; 35(1):94-101. PubMed ID: 37783268
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of perfused volume segmentation between cone-beam CT and
    Martin M; Hocquelet A; Debordeaux F; Bordenave L; Blanc JF; Papadopoulos P; Lapuyade B; Trillaud H; Pinaquy JB
    Diagn Interv Imaging; 2021 Jan; 102(1):45-52. PubMed ID: 33032960
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Correlation of Technetium-99m Macroaggregated Albumin and Yttrium-90 Glass Microsphere Biodistribution in Hepatocellular Carcinoma: A Retrospective Review of Pretreatment Single Photon Emission CT and Posttreatment Positron Emission Tomography/CT.
    Haste P; Tann M; Persohn S; LaRoche T; Aaron V; Mauxion T; Chauhan N; Dreher MR; Johnson MS
    J Vasc Interv Radiol; 2017 May; 28(5):722-730.e1. PubMed ID: 28238581
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radioembolization of hepatocarcinoma with (90)Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology.
    Chiesa C; Mira M; Maccauro M; Spreafico C; Romito R; Morosi C; Camerini T; Carrara M; Pellizzari S; Negri A; Aliberti G; Sposito C; Bhoori S; Facciorusso A; Civelli E; Lanocita R; Padovano B; Migliorisi M; De Nile MC; Seregni E; Marchianò A; Crippa F; Mazzaferro V
    Eur J Nucl Med Mol Imaging; 2015 Oct; 42(11):1718-1738. PubMed ID: 26112387
    [TBL] [Abstract][Full Text] [Related]  

  • 25.
    Tabotta F; Gnesin S; Dunet V; Ponti A; Digklia A; Boughdad S; Schaefer N; Prior JO; Villard N; Tsoumakidou G; Denys A; Duran R
    Sci Rep; 2023 Aug; 13(1):13118. PubMed ID: 37573346
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Quantitative comparison of pre-therapy
    Knešaurek K; Tuli A; Pasik SD; Heiba S; Kostakoglu L
    Eur J Radiol; 2018 Dec; 109():57-61. PubMed ID: 30527312
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.
    Jha AK; Zade AA; Rangarajan V; Purandare N; Shah SA; Agrawal A; Kulkarni SS; Shetty N
    Nucl Med Commun; 2012 May; 33(5):486-90. PubMed ID: 22395029
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High quality imaging and dosimetry for yttrium-90 (
    Duan H; Khalaf MH; Ferri V; Baratto L; Srinivas SM; Sze DY; Iagaru A
    Eur J Nucl Med Mol Imaging; 2021 Jul; 48(8):2426-2436. PubMed ID: 33443618
    [TBL] [Abstract][Full Text] [Related]  

  • 29.
    Nezami N; Kokabi N; Camacho JC; Schuster DM; Xing M; Kim HS
    Nucl Med Biol; 2018 Apr; 59():22-28. PubMed ID: 29448165
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Outpatient single-session yttrium-90 glass microsphere radioembolization.
    Gates VL; Marshall KG; Salzig K; Williams M; Lewandowski RJ; Salem R
    J Vasc Interv Radiol; 2014 Feb; 25(2):266-70. PubMed ID: 24332243
    [TBL] [Abstract][Full Text] [Related]  

  • 31. SPECT and CT misregistration reduction in [
    Lu Z; Chen G; Jiang H; Sun J; Lin KH; Mok GSP
    Eur J Nucl Med Mol Imaging; 2023 Jul; 50(8):2319-2330. PubMed ID: 36877236
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Feasibility of temporary protective embolization of normal liver tissue using degradable starch microspheres during radioembolization of liver tumours.
    Meyer C; Pieper CC; Ezziddin S; Wilhelm KE; Schild HH; Ahmadzadehfar H
    Eur J Nucl Med Mol Imaging; 2014 Feb; 41(2):231-7. PubMed ID: 24030669
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of factors affecting tumor response and survival in patients with primary and metastatic liver cancer treated with microspheres.
    Demirelli S; Erkilic M; Oner AO; Budak ES; Gunduz S; Ozgur O; Bozcuk H; Sindel HT; Boz A
    Nucl Med Commun; 2015 Apr; 36(4):340-9. PubMed ID: 25563137
    [TBL] [Abstract][Full Text] [Related]  

  • 34. (⁹⁹m)Tc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with ¹⁶⁶Ho-microspheres.
    Elschot M; Nijsen JF; Lam MG; Smits ML; Prince JF; Viergever MA; van den Bosch MA; Zonnenberg BA; de Jong HW
    Eur J Nucl Med Mol Imaging; 2014 Oct; 41(10):1965-75. PubMed ID: 24819055
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hepatic falciform ligament Tc-99m-macroaggregated albumin activity on SPECT/CT prior to Yttrium-90 microsphere radioembolization: prophylactic measures to prevent non-target microsphere localization via patent hepatic falciform arteries.
    Kao YH; Tan AE; Khoo LS; Lo RH; Chow PK; Goh AS
    Ann Nucl Med; 2011 Jun; 25(5):365-9. PubMed ID: 21234723
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Is a Technetium-99m Macroaggregated Albumin Scan Essential in the Workup for Selective Internal Radiation Therapy with Yttrium-90? An Analysis of 532 Patients.
    Sancho L; Rodriguez-Fraile M; Bilbao JI; Beorlegui Arteta C; Iñarrairaegui M; Moran V; Sangro B
    J Vasc Interv Radiol; 2017 Nov; 28(11):1536-1542. PubMed ID: 28916345
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization.
    Lenoir L; Edeline J; Rolland Y; Pracht M; Raoul JL; Ardisson V; Bourguet P; Clément B; Boucher E; Garin E
    Eur J Nucl Med Mol Imaging; 2012 May; 39(5):872-80. PubMed ID: 22237844
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical impact of (99m)Tc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with (90)Y-loaded microspheres.
    Garin E; Rolland Y; Laffont S; Edeline J
    Eur J Nucl Med Mol Imaging; 2016 Mar; 43(3):559-75. PubMed ID: 26338177
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy and reproducibility of a cone beam CT-based virtual parenchymal perfusion algorithm in the prediction of SPECT/CT anatomical and volumetric results during the planification of radioembolization for HCC.
    Derbel H; Krichen M; Chalaye J; Saccenti L; Van der Sterren W; Muris AH; Lerman L; Galletto A; Zaarour Y; Luciani A; Kobeiter H; Tacher V
    Eur Radiol; 2023 May; 33(5):3510-3520. PubMed ID: 36651956
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tumor-to-Normal Ratio Relationship between Planning Technetium-99 Macroaggregated Albumin and Posttherapy Yttrium-90 Bremsstrahlung SPECT/CT.
    Villalobos A; Cheng B; Wagstaff W; Sethi I; Bercu Z; Schuster DM; Brandon DC; Galt J; Kokabi N
    J Vasc Interv Radiol; 2021 May; 32(5):752-760. PubMed ID: 33642158
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.