These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 21361591)

  • 1. Improved hydrogen ionization rate in enhanced glow discharge plasma immersion ion implantation by enlarging the interaction path using an insulating tube.
    Wang Z; Zhu Y; Li LH; Lu QY; He FS; Dun DD; Li F; Fu RK; Chu PK
    Rev Sci Instrum; 2011 Feb; 82(2):023503. PubMed ID: 21361591
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved ion implant fluence uniformity in hydrogen enhanced glow discharge plasma immersion ion implantation into silicon.
    Luo J; Li LH; Liu HT; Yu KM; Xu Y; Zuo XJ; Zhu PZ; Ma YF; Fu RK; Chu PK
    Rev Sci Instrum; 2014 Jun; 85(6):063506. PubMed ID: 24985818
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rydberg gas theory of a glow discharge plasma: I. Application to the electrical behaviour of a fast flowing glow discharge plasma.
    Mason RS; Mitchell DJ; Dickinson PM
    Phys Chem Chem Phys; 2010 Apr; 12(15):3698-717. PubMed ID: 20358066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of soft plasma ionization (SPI) source for analysis of organic compounds.
    Park H; Lee I; Choi KS; Wagatsuma K; Lee SC
    Talanta; 2007 Jul; 72(5):1659-66. PubMed ID: 19071813
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct coupling of pulsed radio frequency and pulsed high power in novel pulsed power system for plasma immersion ion implantation.
    Gong C; Tian X; Yang S; Fu RK; Chu PK
    Rev Sci Instrum; 2008 Apr; 79(4):043501. PubMed ID: 18447526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dopant-enhanced atmospheric pressure glow discharge ionization source for ion mobility spectrometry.
    Dong C; Wang L; Wang W; Hou K; Li H
    Rev Sci Instrum; 2008 Oct; 79(10):104101. PubMed ID: 19044731
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New method of plasma immersion ion implantation and also deposition of industrial components using tubular fixture and plasma generated inside the tube by high voltage pulses.
    Ueda M; da Silva AR; Pillaca EJ; Mariano SF; Oliveira Rde M; Rossi JO; Lepienski CM; Pichon L
    Rev Sci Instrum; 2016 Jan; 87(1):013902. PubMed ID: 26827328
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Measurement of rotational temperature in N2 DC glow discharge by optical emission spectroscopy].
    Liu LY; Zhang JL; Ma TC; Deng XL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Dec; 22(6):1013-8. PubMed ID: 12914187
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Broad-beam high-current dc ion source based on a two-stage glow discharge plasma.
    Vizir AV; Oks EM; Yushkov GY
    Rev Sci Instrum; 2010 Feb; 81(2):02B304. PubMed ID: 20192427
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inverted end-Hall-type low-energy high-current gaseous ion source.
    Oks EM; Vizir AV; Shandrikov MV; Yushkov GY; Grishin DM; Anders A; Baldwin DA
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02B302. PubMed ID: 18315168
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].
    Li XC; Jia PY; Liu ZH; Li LC; Dong LF
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Dec; 28(12):2741-4. PubMed ID: 19248473
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvement of surface bioactivity on titanium by water and hydrogen plasma immersion ion implantation.
    Xie Y; Liu X; Huang A; Ding C; Chu PK
    Biomaterials; 2005 Nov; 26(31):6129-35. PubMed ID: 15885768
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gridless, very low energy, high-current, gaseous ion source.
    Vizir AV; Shandrikov MV; Yushkov GY; Oks EM
    Rev Sci Instrum; 2010 Feb; 81(2):02B307. PubMed ID: 20192430
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Spatial distribution of electrons with high energy in atmospheric pressure glow discharge excited by DC voltage].
    Liu ZQ; Jia PY; Liu T
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Sep; 33(9):2321-4. PubMed ID: 24369623
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dust particle radial confinement in a dc glow discharge.
    Sukhinin GI; Fedoseev AV; Antipov SN; Petrov OF; Fortov VE
    Phys Rev E Stat Nonlin Soft Matter Phys; 2013 Jan; 87(1):013101. PubMed ID: 23410440
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mathematical description of a direct current glow discharge in argon.
    Bogaerts A; Gijbels R
    Anal Bioanal Chem; 1996 Jul; 355(7-8):853-7. PubMed ID: 15045278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the ionic chemistry in DC cold plasmas of H2 with Ar.
    Méndez I; Tanarro I; Herrero VJ
    Phys Chem Chem Phys; 2010 Apr; 12(16):4239-45. PubMed ID: 20379518
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of an rf-powered magnetron glow discharge for the trace analysis of glasses and ceramics.
    Saprykin AI; Becker JS; Dietze HJ
    Anal Bioanal Chem; 1996 Jul; 355(7-8):831-5. PubMed ID: 15045274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement and analysis of discharge current in dielectric barrier glow discharge at atmospheric pressure].
    Li XC; Yin ZQ; Pang XX; Li YH; Gao RL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2007 Dec; 27(12):2403-5. PubMed ID: 18330271
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical emission spectroscopy in reactive hollow cathode arc discharge plasmas - Local distribution of active species during the deposition of hard carbon films.
    Hemel V; Bolt H; Koch F; Nickel H
    Anal Bioanal Chem; 1996 Jun; 355(3-4):244-6. PubMed ID: 15045373
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.