BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

409 related articles for article (PubMed ID: 21362692)

  • 1. Principles for the design and calibration of radiation protection dosemeters for operational and protection quantities for eye lens dosimetry.
    Bordy JM; Gualdrini G; Daures J; Mariotti F
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):257-61. PubMed ID: 21362692
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Eye lens dosimetry: task 2 within the ORAMED project.
    Gualdrini G; Mariotti F; Wach S; Bilski P; Denoziere M; Daures J; Bordy JM; Ferrari P; Monteventi F; Fantuzzi E
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):473-7. PubMed ID: 21335629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,alpha).
    Mariotti F; Fantuzzi E; Morelli B; Gualdrini G; Botta MC; Uleri G; Bordy JM; Denoziere M
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):187-91. PubMed ID: 21224262
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring the eye lens: which dose quantity is adequate?
    Behrens R; Dietze G
    Phys Med Biol; 2010 Jul; 55(14):4047-62. PubMed ID: 20601777
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hp(0.07) photon dosemeters for eye lens dosimetry: calibration on a rod vs. a slab phantom.
    Behrens R; Engelhardt J; Figel M; Hupe O; Jordan M; Seifert R
    Radiat Prot Dosimetry; 2012 Jan; 148(2):139-42. PubMed ID: 21393309
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetry.
    Koukorava C; Carinou E; Simantirakis G; Vrachliotis TG; Archontakis E; Tierris C; Dimitriou P
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):482-6. PubMed ID: 21044993
    [TBL] [Abstract][Full Text] [Related]  

  • 7. INFLUENCE OF DIFFERENT TYPES OF PHANTOMS ON THE CALIBRATION OF DOSEMETERS FOR EYE LENS DOSIMETRY.
    Yoshitomi H; Kowatari M
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):199-203. PubMed ID: 27026745
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the operational quantity H(p)(3) for eye lens dosimetry.
    Behrens R
    J Radiol Prot; 2012 Dec; 32(4):455-64. PubMed ID: 23146823
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulations.
    Daures J; Gouriou J; Bordy JM
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):37-42. PubMed ID: 21242167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intercomparison on measurements of the quantity personal dose equivalent Hp(10) in photon fields in the African region.
    Msimang Z; Cruz-Suárez R; Zeger J
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):282-6. PubMed ID: 21112891
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.
    Carinou E; Ferrari P; Bjelac OC; Gingaume M; Merce MS; O'Connor U
    J Radiol Prot; 2015 Sep; 35(3):R17-34. PubMed ID: 26343787
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of active personal dosemeters as a personal monitoring device: comparison with TL dosimetry.
    Boziari A; Koukorava C; Carinou E; Hourdakis CJ; Kamenopoulou V
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):173-6. PubMed ID: 21196464
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of angular distributions of workplace photon fields in a context of effective dose estimation.
    Volosky V; Bakhanova E; Chumak V
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):636-9. PubMed ID: 21450705
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effective dose measurement at workplaces within an instrumented anthropomorphic phantom.
    Villagrasa C; Darréon J; Martin-Burtat N; Clairand I; Colin J; Fontbonne JM
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):640-4. PubMed ID: 21051438
    [TBL] [Abstract][Full Text] [Related]  

  • 15. EURADOS 2016 INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS.
    Clairand I; Behrens R; Brodecki M; Carinou E; Domienik-Andrzejewska J; Ginjaume M; Hupe O; Roig M
    Radiat Prot Dosimetry; 2018 Dec; 182(3):317-322. PubMed ID: 30590842
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fluence to Hp(3) conversion coefficients for neutrons from thermal to 15 MeV.
    Gualdrini G; Ferrari P; Tanner R
    Radiat Prot Dosimetry; 2013 Dec; 157(2):278-90. PubMed ID: 23671134
    [TBL] [Abstract][Full Text] [Related]  

  • 17. FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.
    Clairand I; Ginjaume M; Vanhavere F; Carinou E; Daures J; Denoziere M; Silva EH; Roig M; Principi S; Van Rycheghem L
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):21-6. PubMed ID: 26163384
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Active personal dosemeters in interventional radiology: tests in laboratory conditions and in hospitals.
    Clairand I; Bordy JM; Daures J; Debroas J; Denozière M; Donadille L; Ginjaume M; Itié C; Koukorava C; Krim S; Lebacq AL; Martin P; Struelens L; Sans-Mercé M; Tosic M; Vanhavere F
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):453-8. PubMed ID: 21186215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. AIR KERMA TO Hp(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICS.
    Principi S; Guardiola C; Duch MA; Ginjaume M
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):45-8. PubMed ID: 26464527
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Field calibration of dosemeters used for routine measurements at flight altitudes.
    Wissmann F; Burmeister S; Dönsdorf E; Heber B; Hubiak M; Klages T; Langner F; Möller T; Meier M
    Radiat Prot Dosimetry; 2010 Aug; 140(4):319-25. PubMed ID: 20484163
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.