BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 21364410)

  • 1. Tissue oximetry monitoring in microsurgical breast reconstruction decreases flap loss and improves rate of flap salvage.
    Lin SJ; Nguyen MD; Chen C; Colakoglu S; Curtis MS; Tobias AM; Lee BT
    Plast Reconstr Surg; 2011 Mar; 127(3):1080-1085. PubMed ID: 21364410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does Increased Experience with Tissue Oximetry Monitoring in Microsurgical Breast Reconstruction Lead to Decreased Flap Loss? The Learning Effect.
    Koolen PGL; Vargas CR; Ho OA; Ibrahim AMS; Ricci JA; Tobias AM; Winters HAH; Lin SJ; Lee BT
    Plast Reconstr Surg; 2016 Apr; 137(4):1093-1101. PubMed ID: 27018663
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Novel Free Flap Monitoring System Using Tissue Oximetry with Text Message Alerts.
    Ricci JA; Vargas CR; Lin SJ; Tobias AM; Taghinia AH; Lee BT
    J Reconstr Microsurg; 2016 Jun; 32(5):415-20. PubMed ID: 27135144
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction.
    Ricci JA; Vargas CR; Ho OA; Lin SJ; Tobias AM; Lee BT
    Ann Plast Surg; 2017 Jul; 79(1):42-46. PubMed ID: 28296715
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements.
    Keller A
    Ann Plast Surg; 2009 May; 62(5):538-43. PubMed ID: 19387157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring Breast Reconstruction Flaps Using Near-Infrared Spectroscopy Tissue Oximetry.
    Kumbasar DE; Hagiga A; Dawood O; Berner JE; Blackburn A
    Plast Surg Nurs; 2021 Apr-Jun 01; 41(2):108-111. PubMed ID: 34033637
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical variations of the bipedicled TRAM flap in unilateral breast reconstruction: effects of conventional versus microsurgical techniques of pedicle transfer on complications rates.
    Ng RL; Youssef A; Kronowitz SJ; Lipa JE; Potochny J; Reece GP
    Plast Reconstr Surg; 2004 Aug; 114(2):374-84; discussion 385-8. PubMed ID: 15277802
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noninvasive tissue oximetry for flap monitoring: an initial study.
    Keller A
    J Reconstr Microsurg; 2007 May; 23(4):189-97. PubMed ID: 17530610
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The False Positive Rate of Transcutaneous Tissue Oximetry Alarms in Microvascular Breast Reconstruction Rises after 24 Hours.
    Tran PC; DeBrock W; Lester ME; Hartman BC; Socas J; Hassanein AH
    J Reconstr Microsurg; 2021 Jun; 37(5):453-557. PubMed ID: 33129214
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing tissue oximetry to doppler monitoring in 1367 consecutive breast free flaps.
    Johnson BM; Cullom ME; Egan KG; Nazir N; Elver AA; Limpiado MJ; Lai EC; Butterworth JA
    Microsurgery; 2023 Jan; 43(1):57-62. PubMed ID: 35238069
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Unilateral failures in bilateral microvascular breast reconstruction.
    Rao SS; Parikh PM; Goldstein JA; Nahabedian MY
    Plast Reconstr Surg; 2010 Jul; 126(1):17-25. PubMed ID: 20595829
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers.
    Chen KT; Mardini S; Chuang DC; Lin CH; Cheng MH; Lin YT; Huang WC; Tsao CK; Wei FC
    Plast Reconstr Surg; 2007 Jul; 120(1):187-195. PubMed ID: 17572562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Simplified Cost-Utility Analysis of Inpatient Flap Monitoring after Microsurgical Breast Reconstruction and Implications for Hospital Length of Stay.
    Jablonka EM; Lamelas AM; Kanchwala SK; Rhemtulla I; Smith ML
    Plast Reconstr Surg; 2019 Oct; 144(4):540e-549e. PubMed ID: 31568278
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Alternative venous outflow vessels in microvascular breast reconstruction.
    Mehrara BJ; Santoro T; Smith A; Arcilla EA; Watson JP; Shaw WW; Da Lio AL
    Plast Reconstr Surg; 2003 Aug; 112(2):448-55. PubMed ID: 12900602
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases.
    Disa JJ; Cordeiro PG; Hidalgo DA
    Plast Reconstr Surg; 1999 Jul; 104(1):97-101. PubMed ID: 10597680
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Trials and tribulations with the inferior gluteal artery perforator flap in autologous breast reconstruction.
    Mirzabeigi MN; Au A; Jandali S; Natoli N; Sbitany H; Serletti JM
    Plast Reconstr Surg; 2011 Dec; 128(6):614e-624e. PubMed ID: 22094760
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The efficacy of postoperative monitoring: a single surgeon comparison of clinical monitoring and the implantable Doppler probe in 547 consecutive free flaps.
    Rozen WM; Chubb D; Whitaker IS; Acosta R
    Microsurgery; 2010; 30(2):105-10. PubMed ID: 19790183
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Remote monitoring of head and neck free flaps using near infrared spectroscopic tissue oximetry.
    Starr NC; Slade E; Gal TJ; Adekunle A; Bigler D; Cheung B; Wang D; Yeoh M; Liau J; Kejner A
    Am J Otolaryngol; 2021; 42(1):102834. PubMed ID: 33229129
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Free flap reexploration: indications, treatment, and outcomes in 1193 free flaps.
    Bui DT; Cordeiro PG; Hu QY; Disa JJ; Pusic A; Mehrara BJ
    Plast Reconstr Surg; 2007 Jun; 119(7):2092-2100. PubMed ID: 17519706
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A systematic approach to emergent breast free flap takeback: Clinical outcomes, algorithm, and review of the literature.
    Khansa I; Chao AH; Taghizadeh M; Nagel T; Wang D; Tiwari P
    Microsurgery; 2013 Oct; 33(7):505-13. PubMed ID: 23946137
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.