These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 21364757)

  • 21. A comparative study on the reliability of the fluorescence microscopy and Ziehl-Neelsen method in the diagnosis of pulmonary tuberculosis.
    Githui W; Kitui F; Juma ES; Obwana DO; Mwai J; Kwamanga D
    East Afr Med J; 1993 May; 70(5):263-6. PubMed ID: 8306899
    [TBL] [Abstract][Full Text] [Related]  

  • 22. LED-fluorescence microscopy for diagnosis of pulmonary tuberculosis under programmatic conditions in India.
    Reza LW; Satyanarayna S; Enarson DA; Kumar AM; Sagili K; Kumar S; Prabhakar LA; Devendrappa NM; Pandey A; Wilson N; Chadha S; Thapa B; Sachdeva KS; Kohli MP
    PLoS One; 2013; 8(10):e75566. PubMed ID: 24130719
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mobile digital fluorescence microscopy for diagnosis of tuberculosis.
    Tapley A; Switz N; Reber C; Davis JL; Miller C; Matovu JB; Worodria W; Huang L; Fletcher DA; Cattamanchi A
    J Clin Microbiol; 2013 Jun; 51(6):1774-8. PubMed ID: 23554191
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum.
    Marais BJ; Brittle W; Painczyk K; Hesseling AC; Beyers N; Wasserman E; van Soolingen D; Warren RM
    Clin Infect Dis; 2008 Jul; 47(2):203-7. PubMed ID: 18532893
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison Of Ziehl-Neelsen Based Light Microscopy With Led Fluorescent Microscopy For Tuberculosis Diagnosis: An Insight From A Limited Resource-High Burden setting.
    Noori MY; Ali F; Ali Z; Sharafat S
    J Ayub Med Coll Abbottabad; 2017; 29(4):577-579. PubMed ID: 29330981
    [TBL] [Abstract][Full Text] [Related]  

  • 26. SeeTB: A novel alternative to sputum smear microscopy to diagnose tuberculosis in high burden countries.
    Pandey V; Singh P; Singh S; Arora N; Quadir N; Singh S; Das A; Dudeja M; Kapur P; Ehtesham NZ; Elangovan R; Hasnain SE
    Sci Rep; 2019 Nov; 9(1):16371. PubMed ID: 31719539
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Light Emitting Diode Fluorescence Microscopy increased the detection of smear-positives during follow-up of Tuberculosis patients in India: program implications.
    Thapa B; Reza LW; Kumar AM; Pandey A; Satyanarayana S; Chadha S
    BMC Res Notes; 2015 Oct; 8():596. PubMed ID: 26499322
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Usefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.
    Khatun Z; Kamal M; Roy CK; Sultana T; Rahman MQ; Azad MB; Ahmed AN
    Bangladesh Med Res Counc Bull; 2011 Apr; 37(1):7-10. PubMed ID: 21710809
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Light-emitting diode fluorescence microscopy for tuberculosis diagnosis: a meta-analysis.
    Chang EW; Page AL; Bonnet M
    Eur Respir J; 2016 Mar; 47(3):929-37. PubMed ID: 26647430
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Multicentre evaluation of Ziehl-Neelsen and light-emitting diode fluorescence microscopy in China.
    Xia H; Song YY; Zhao B; Kam KM; O'Brien RJ; Zhang ZY; Sohn H; Wang W; Zhao YL
    Int J Tuberc Lung Dis; 2013 Jan; 17(1):107-12. PubMed ID: 23232010
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Optimising Mycobacterium tuberculosis detection in resource limited settings.
    Alfred N; Lovette L; Aliyu G; Olusegun O; Meshak P; Jilang T; Iwakun M; Nnamdi E; Olubunmi O; Dakum P; Abimiku A
    BMJ Open; 2014 Mar; 4(3):e004093. PubMed ID: 24589822
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Performance and acceptability of the FluoLED Easy module for tuberculosis fluorescence microscopy.
    Van Deun A; Chonde TM; Gumusboga M; Rienthong S
    Int J Tuberc Lung Dis; 2008 Sep; 12(9):1009-14. PubMed ID: 18713497
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Integrated strategies to optimize sputum smear microscopy: a prospective observational study.
    Cattamanchi A; Huang L; Worodria W; den Boon S; Kalema N; Katagira W; Byanyima P; Yoo S; Matovu J; Hopewell PC; Davis JL
    Am J Respir Crit Care Med; 2011 Feb; 183(4):547-51. PubMed ID: 20851925
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Is frontloaded sputum microscopy an option in active tuberculosis case finding?
    Lorent N; Buyze J; Kim T; Kong C; Van Deun A; Colebunders R; Thai S; Lynen L; Rigouts L
    Int J Tuberc Lung Dis; 2015 Jan; 19(1):91-6. PubMed ID: 25519797
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of LED and conventional fluorescence microscopy for detection of acid-fast bacilli in an area with high tuberculosis incidence.
    Marzouk M; Ferjani A; Dhaou M; Ali MH; Hannachi N; Boukadida J
    Diagn Microbiol Infect Dis; 2013 Jul; 76(3):306-8. PubMed ID: 23632250
    [TBL] [Abstract][Full Text] [Related]  

  • 36. No added value of performing Ziehl-Neelsen on auramine-positive samples for tuberculosis diagnostics.
    den Hertog AL; Daher S; Straetemans M; Scholing M; Anthony RM
    Int J Tuberc Lung Dis; 2013 Aug; 17(8):1094-9. PubMed ID: 23827035
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparative study of fluorescent microscopy with Ziehl-Neelsen staining and culture for the diagnosis of pulmonary tuberculosis.
    Laifangbam S; Singh HL; Singh NB; Devi KM; Singh NT
    Kathmandu Univ Med J (KUMJ); 2009; 7(27):226-30. PubMed ID: 20071867
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The CyScope® fluorescence microscope, a reliable tool for tuberculosis diagnosis in resource-limited settings.
    Lehman LG; Ngapmen Yamadji AL; Ngo Sack F; Bilong Bilong CF
    Am J Trop Med Hyg; 2010 Oct; 83(4):906-8. PubMed ID: 20889889
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of mobile digital light-emitting diode fluorescence microscopy in Hanoi, Viet Nam.
    Chaisson LH; Reber C; Phan H; Switz N; Nilsson LM; Myers F; Nhung NV; Luu L; Pham T; Vu C; Nguyen H; Nguyen A; Dinh T; Nahid P; Fletcher DA; Cattamanchi A
    Int J Tuberc Lung Dis; 2015 Sep; 19(9):1068-72. PubMed ID: 26260826
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A comparative study on the different staining methods and number of specimens for the detection of acid fast bacilli.
    Ulukanligil M; Aslan G; Tasçi S
    Mem Inst Oswaldo Cruz; 2000; 95(6):855-8. PubMed ID: 11080774
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.