240 related articles for article (PubMed ID: 21372650)
1. Validation of a noninvasive technique to precisely measure in vivo three-dimensional cervical spine movement.
Anderst WJ; Baillargeon E; Donaldson WF; Lee JY; Kang JD
Spine (Phila Pa 1976); 2011 Mar; 36(6):E393-400. PubMed ID: 21372650
[TBL] [Abstract][Full Text] [Related]
2. Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings.
McDonald CP; Bachison CC; Chang V; Bartol SW; Bey MJ
Spine J; 2010 Jun; 10(6):497-504. PubMed ID: 20359957
[TBL] [Abstract][Full Text] [Related]
3. A technique to measure three-dimensional in vivo rotation of fused and adjacent lumbar vertebrae.
Anderst WJ; Vaidya R; Tashman S
Spine J; 2008; 8(6):991-7. PubMed ID: 17919983
[TBL] [Abstract][Full Text] [Related]
4. Continuous cervical spine kinematics during in vivo dynamic flexion-extension.
Anderst WJ; Donaldson WF; Lee JY; Kang JD
Spine J; 2014 Jul; 14(7):1221-7. PubMed ID: 24210579
[TBL] [Abstract][Full Text] [Related]
5. Intervertebral kinematics of the cervical spine before, during, and after high-velocity low-amplitude manipulation.
Anderst WJ; Gale T; LeVasseur C; Raj S; Gongaware K; Schneider M
Spine J; 2018 Dec; 18(12):2333-2342. PubMed ID: 30142458
[TBL] [Abstract][Full Text] [Related]
6. Validation of three-dimensional model-based tibio-femoral tracking during running.
Anderst W; Zauel R; Bishop J; Demps E; Tashman S
Med Eng Phys; 2009 Jan; 31(1):10-6. PubMed ID: 18434230
[TBL] [Abstract][Full Text] [Related]
7. Cervical kinematics after fusion and bryan disc arthroplasty.
Sasso RC; Best NM
J Spinal Disord Tech; 2008 Feb; 21(1):19-22. PubMed ID: 18418131
[TBL] [Abstract][Full Text] [Related]
8. Bootstrap prediction bands for cervical spine intervertebral kinematics during in vivo three-dimensional head movements.
Anderst WJ
J Biomech; 2015 May; 48(7):1270-6. PubMed ID: 25798763
[TBL] [Abstract][Full Text] [Related]
9. Three-dimensional kinematic analysis of the cervical spine after anterior cervical decompression and fusion at an adjacent level: a preliminary report.
Watanabe S; Inoue N; Yamaguchi T; Hirano Y; Espinoza Orías AA; Nishida S; Hirose Y; Mizuno J
Eur Spine J; 2012 May; 21(5):946-55. PubMed ID: 22124708
[TBL] [Abstract][Full Text] [Related]
10. Capturing three-dimensional in vivo lumbar intervertebral joint kinematics using dynamic stereo-X-ray imaging.
Aiyangar AK; Zheng L; Tashman S; Anderst WJ; Zhang X
J Biomech Eng; 2014 Jan; 136(1):011004. PubMed ID: 24149991
[TBL] [Abstract][Full Text] [Related]
11. In vivo three-dimensional intervertebral kinematics of the subaxial cervical spine during seated axial rotation and lateral bending via a fluoroscopy-to-CT registration approach.
Lin CC; Lu TW; Wang TM; Hsu CY; Hsu SJ; Shih TF
J Biomech; 2014 Oct; 47(13):3310-7. PubMed ID: 25218506
[TBL] [Abstract][Full Text] [Related]
12. Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.
Anderst WJ; Donaldson WF; Lee JY; Kang JD
J Biomech; 2015 May; 48(7):1286-93. PubMed ID: 25814180
[TBL] [Abstract][Full Text] [Related]
13. In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency.
Tashman S; Anderst W
J Biomech Eng; 2003 Apr; 125(2):238-45. PubMed ID: 12751286
[TBL] [Abstract][Full Text] [Related]
14. Three-dimensional motion analysis of the cervical spine for comparison of anterior cervical decompression and fusion versus artificial disc replacement in 17 patients: clinical article.
McDonald CP; Chang V; McDonald M; Ramo N; Bey MJ; Bartol S
J Neurosurg Spine; 2014 Mar; 20(3):245-55. PubMed ID: 24359000
[TBL] [Abstract][Full Text] [Related]
15. Index and adjacent level kinematics after cervical disc replacement and anterior fusion: in vivo quantitative radiographic analysis.
Park DK; Lin EL; Phillips FM
Spine (Phila Pa 1976); 2011 Apr; 36(9):721-30. PubMed ID: 20543765
[TBL] [Abstract][Full Text] [Related]
16. Validation and application of a novel in vivo cervical spine kinematics analysis technique.
Wan Z; Wang W; Li C; Li J; Lin J; Tian F; Zhu T; Wu D; Guo L; Wang S
Sci Rep; 2021 Dec; 11(1):24266. PubMed ID: 34930931
[TBL] [Abstract][Full Text] [Related]
17. Dynamic foraminal dimensions during neck extension and rotation in fusion and artificial disc replacement: an observational study.
Yeni YN; Baumer T; Oravec D; Basheer A; McDonald CP; Bey MJ; Bartol SW; Chang V
Spine J; 2018 Apr; 18(4):575-583. PubMed ID: 28882520
[TBL] [Abstract][Full Text] [Related]
18. Surgery-related Factors Do Not Affect Short-term Adjacent Segment Kinematics After Anterior Cervical Arthrodesis.
Chen SR; LeVasseur CM; Pitcairn S; Kanter AS; Okonkwo DO; Shaw JD; Donaldson WF; Lee JY; Anderst WJ
Spine (Phila Pa 1976); 2021 Dec; 46(23):1630-1636. PubMed ID: 33907081
[TBL] [Abstract][Full Text] [Related]
19. In vivo three-dimensional kinematics of the cervical spine during maximal active head rotation.
Kang J; Chen G; Zhai X; He X
PLoS One; 2019; 14(4):e0215357. PubMed ID: 30990826
[TBL] [Abstract][Full Text] [Related]
20. [In vivo measurement of three-dimensional motion of the upper cervical spine using CT three-dimensional reconstruction].
Zhai X; Kang J; Chen X; Dong J; Qiu XW; Ding XA; Liu J; He XJ
Zhongguo Gu Shang; 2019 Jul; 32(7):658-665. PubMed ID: 31382726
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]