These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 21374715)

  • 1. The "periosteal anchor stitch": opening up the surgical field.
    Shah AK; Barabas A; Matthews A; Sassoon E; Haywood R
    Microsurgery; 2011 Mar; 31(3):251-2. PubMed ID: 21374715
    [No Abstract]   [Full Text] [Related]  

  • 2. The internal mammary artery and vein as recipient vessels for microvascular breast reconstruction.
    Nahabedian M
    Ann Plast Surg; 2012 May; 68(5):537-8. PubMed ID: 22531410
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The thoracodorsal artery and vein as recipient vessels for microsurgical breast reconstruction.
    Banwell M; Trotter D; Ramakrishnan V
    Ann Plast Surg; 2012 May; 68(5):542-3. PubMed ID: 22214794
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Potential of performing a microvascular free flap reconstruction using solely a 3D exoscope instead of a conventional microscope.
    Piatkowski AA; Keuter XHA; Schols RM; van der Hulst RRWJ
    J Plast Reconstr Aesthet Surg; 2018 Nov; 71(11):1664-1678. PubMed ID: 30143338
    [No Abstract]   [Full Text] [Related]  

  • 5. Tips for successful microvascular abdominal flap breast reconstruction utilizing the "total rib preservation" technique for internal mammary vessel exposure.
    Malata CM; Moses M; Mickute Z; Di Candia M
    Ann Plast Surg; 2011 Jan; 66(1):36-42. PubMed ID: 21102306
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Strategies in case of unusable internal mammary vessels in a mammary reconstruction by DIEP].
    Cohen-Hayoun E; Pessis R; Lkah C; Atlan M
    Ann Chir Plast Esthet; 2013 Feb; 58(1):69-73. PubMed ID: 23153633
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A stitch in time, which is perfectly aligned, saves nine.
    Wallace CG; Sainsbury DC; Jones ME
    Microsurgery; 2008; 28(5):392-3. PubMed ID: 18561265
    [No Abstract]   [Full Text] [Related]  

  • 8. Thoracodorsal or internal mammary recipient vessels for microvascular breast reconstruction?
    Wallace CG; Shokrollahi K
    Ann Plast Surg; 2012 May; 68(5):536. PubMed ID: 22531409
    [No Abstract]   [Full Text] [Related]  

  • 9. Anterograde and retrograde flow anastomoses to the internal mammary vessels in the third intercostal space.
    Salgarello M; Cervelli D; Barone-Adesi L; Finocchi V
    J Reconstr Microsurg; 2010 Nov; 26(9):637-8. PubMed ID: 20683813
    [No Abstract]   [Full Text] [Related]  

  • 10. [Pedicled versus free TRAM flap for breast reconstruction].
    Galla TJ; Lukas B; Feller AM
    Handchir Mikrochir Plast Chir; 1999 Mar; 31(2):126-33. PubMed ID: 10337558
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The St. Andrews recipient algorithm for breast reconstruction: a comparison analysis with other microsurgical units in the world.
    Liem AA; Ramakrishnan V
    Plast Reconstr Surg; 2013 Jan; 131(1):127e-128e. PubMed ID: 23271543
    [No Abstract]   [Full Text] [Related]  

  • 12. Epiperitoneal vessels: more resources to perform DIEP flaps.
    Lasso JM; Sancho M; Campo V; Jiménez E; Pérez Cano R
    J Plast Reconstr Aesthet Surg; 2008 Jul; 61(7):826-9. PubMed ID: 17446150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Breast reconstruction with the deep inferior epigastric perforator flap: history and an update on current technique.
    Granzow JW; Levine JL; Chiu ES; Allen RJ
    J Plast Reconstr Aesthet Surg; 2006; 59(6):571-9. PubMed ID: 16716950
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The bilateral DIEP flap: a method of bipedicled anastomosis to a single internal mammary artery and venae comitantes.
    Barabás AG; Shafighi M; Sassoon EM; Haywood RM
    J Plast Reconstr Aesthet Surg; 2008 Oct; 61(10):1249-51. PubMed ID: 18583209
    [No Abstract]   [Full Text] [Related]  

  • 15. Salvage of SIEA flaps using the retrograde internal mammary system.
    Agarwal JP; Ley E; Tieman J
    Microsurgery; 2010 Oct; 30(7):545-8. PubMed ID: 20853325
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The thoracodorsal vessels are advantageous, reliable, and safe recipient vessels for free abdominal flap breast reconstruction.
    Guay NA
    Ann Plast Surg; 2012 May; 68(5):539-41. PubMed ID: 22531411
    [No Abstract]   [Full Text] [Related]  

  • 17. A technique for atraumatic microvascular arterial coupling.
    Spector JA; Draper LB; Levine JP; Ahn CY
    Plast Reconstr Surg; 2007 May; 119(6):1968-1969. PubMed ID: 17440404
    [No Abstract]   [Full Text] [Related]  

  • 18. Histoacryl® to secure the microvascular venous anastomosis using the coupling device.
    Shah AK; Clibbon JJ
    Microsurgery; 2011 Nov; 31(8):666-7. PubMed ID: 22025382
    [No Abstract]   [Full Text] [Related]  

  • 19. Microvascular coupler-induced intimal crimping causing venous thrombosis.
    Bank J; Teng E; Song DH
    J Reconstr Microsurg; 2015 Feb; 31(2):157-8. PubMed ID: 25290531
    [No Abstract]   [Full Text] [Related]  

  • 20. Caution in the use of the internal mammary artery in breast reconstruction.
    Al-Benna S
    Plast Reconstr Surg; 2007 Jul; 120(1):348. PubMed ID: 17572589
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.