210 related articles for article (PubMed ID: 21376971)
1. An automatic gas-phase molecular absorption spectrometric system using a UV-LED photodiode based detector for determination of nitrite and total nitrate.
Zhang M; Zhang Z; Yuan D; Feng S; Liu B
Talanta; 2011 Apr; 84(2):443-50. PubMed ID: 21376971
[TBL] [Abstract][Full Text] [Related]
2. Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples.
Burakham R; Oshima M; Grudpan K; Motomizu S
Talanta; 2004 Dec; 64(5):1259-65. PubMed ID: 18969739
[TBL] [Abstract][Full Text] [Related]
3. UV-absorbance detector for HPLC based on a light-emitting diode.
Schmid S; Macka M; Hauser PC
Analyst; 2008 Apr; 133(4):465-9. PubMed ID: 18365115
[TBL] [Abstract][Full Text] [Related]
4. A violet light-emitting diode-based gas-phase molecular absorption device for measurement of nitrate and nitrite in environmental water.
Liu C; Gao S; Han X; Tian Y; Ma J; Wang W; Chen XW; Chen ML; Zhang Y
Spectrochim Acta A Mol Biomol Spectrosc; 2024 Sep; 317():124423. PubMed ID: 38759395
[TBL] [Abstract][Full Text] [Related]
5. Sequential flow injection analysis of ammonium and nitrate using gas phase molecular absorption spectrometry.
Haghighi B; Kurd SF
Talanta; 2004 Oct; 64(3):688-94. PubMed ID: 18969660
[TBL] [Abstract][Full Text] [Related]
6. A simple miniaturised photometrical method for rapid determination of nitrate and nitrite in freshwater.
Tu X; Xiao B; Xiong J; Chen X
Talanta; 2010 Aug; 82(3):976-83. PubMed ID: 20678655
[TBL] [Abstract][Full Text] [Related]
7. Low cost 235 nm ultra-violet light-emitting diode-based absorbance detector for application in a portable ion chromatography system for nitrite and nitrate monitoring.
Murray E; Roche P; Harrington K; McCaul M; Moore B; Morrin A; Diamond D; Paull B
J Chromatogr A; 2019 Oct; 1603():8-14. PubMed ID: 31151694
[TBL] [Abstract][Full Text] [Related]
8. Application of manganese(IV) dioxide microcolumn for determination and speciation of nitrite and nitrate using a flow injection analysis-flame atomic absorption spectrometry system.
Noroozifar M; Khorasani-Motlagh M; Taheri A; Homayoonfard M
Talanta; 2007 Jan; 71(1):359-64. PubMed ID: 19071312
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples by ion-pair high-performance liquid chromatography.
Zuo Y; Wang C; Van T
Talanta; 2006 Sep; 70(2):281-5. PubMed ID: 18970764
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous determination of nitrate and nitrite in biological samples by multichannel flow injection analysis.
Pratt PF; Nithipatikom K; Campbell WB
Anal Biochem; 1995 Nov; 231(2):383-6. PubMed ID: 8594989
[TBL] [Abstract][Full Text] [Related]
11. Flow-injection analysis of nitrate by reduction to nitrite and gas-phase molecular absorption spectrometry.
Haghighi B; Tavassoli A
Fresenius J Anal Chem; 2001 Dec; 371(8):1113-8. PubMed ID: 11798108
[TBL] [Abstract][Full Text] [Related]
12. Performance of a New 235 nm UV-LED-Based On-Capillary Photometric Detector.
Li Y; Nesterenko PN; Paull B; Stanley R; Macka M
Anal Chem; 2016 Dec; 88(24):12116-12121. PubMed ID: 27595290
[TBL] [Abstract][Full Text] [Related]
13. Selective determination method for measurement of nitrite and nitrate in water samples using high-performance liquid chromatography with post-column photochemical reaction and chemiluminescence detection.
Kodamatani H; Yamazaki S; Saito K; Tomiyasu T; Komatsu Y
J Chromatogr A; 2009 Apr; 1216(15):3163-7. PubMed ID: 19233366
[TBL] [Abstract][Full Text] [Related]
14. Determination of phosphate using a highly sensitive paired emitter-detector diode photometric flow detector.
O'Toole M; Lau KT; Shepherd R; Slater C; Diamond D
Anal Chim Acta; 2007 Aug; 597(2):290-4. PubMed ID: 17683741
[TBL] [Abstract][Full Text] [Related]
15. Hand-held photometer based on liquid-core waveguide absorption detection for nanoliter-scale samples.
Pan JZ; Yao B; Fang Q
Anal Chem; 2010 Apr; 82(8):3394-8. PubMed ID: 20349997
[TBL] [Abstract][Full Text] [Related]
16. A downsized flow set up based on multicommutation for the sequential photometric determination of iron(II)/iron(III) and nitrite/nitrate in surface water.
Feres MA; Reis BF
Talanta; 2005 Dec; 68(2):422-8. PubMed ID: 18970339
[TBL] [Abstract][Full Text] [Related]
17. Simultaneous spectrophotometric determination of nitrite and nitrate by flow-injection analysis.
Ahmed MJ; Stalikas CD; Tzouwara-Karayanni SM; Karayannis MI
Talanta; 1996 Jul; 43(7):1009-18. PubMed ID: 18966574
[TBL] [Abstract][Full Text] [Related]
18. Electrospray ionization-ion mobility spectrometry: a rapid analytical method for aqueous nitrate and nitrite analysis.
Dwivedi P; Matz LM; Atkinson DA; Hill HH
Analyst; 2004 Feb; 129(2):139-44. PubMed ID: 14752557
[TBL] [Abstract][Full Text] [Related]
19. Flow injection catalytic spectrophotometric simultaneous determination of nitrite and nitrate.
Yue XF; Zhang ZQ; Yan HT
Talanta; 2004 Jan; 62(1):97-101. PubMed ID: 18969269
[TBL] [Abstract][Full Text] [Related]
20. Chemical conversion of nitrate and nitrite to nitrous oxide for nitrogen and oxygen isotopic analysis in freshwater and seawater.
McIlvin MR; Altabet MA
Anal Chem; 2005 Sep; 77(17):5589-95. PubMed ID: 16131070
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]