These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 21377073)

  • 21. A clinical comparison of the Flexiblade and Macintosh laryngoscopes for laryngeal exposure in anesthetized adults.
    Cheung RW; Irwin MG; Law BC; Chan CK
    Anesth Analg; 2006 Feb; 102(2):626-30. PubMed ID: 16428574
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The Cardiff paediatric laryngoscope blade: a comparison with the Miller size 1 and Macintosh size 2 laryngoscope blades.
    Jones RM; Jones PL; Gildersleve CD; Hall JE; Harding LJ; Chawathe MS
    Anaesthesia; 2004 Oct; 59(10):1016-9. PubMed ID: 15488063
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Single-use and reusable laryngoscope blades: a randomized controlled trial in elective surgery].
    Guerci P; Vial F; Bouaziz H
    Can J Anaesth; 2012 Jan; 59(1):114-5. PubMed ID: 21997227
    [No Abstract]   [Full Text] [Related]  

  • 24. Comparison of plastic single-use and metal reusable laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia.
    Amour J; Marmion F; Birenbaum A; Nicolas-Robin A; Coriat P; Riou B; Langeron O
    Anesthesiology; 2006 Jan; 104(1):60-4. PubMed ID: 16394691
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: the comparison of haemodynamic changes with Macintosh blade in a randomized trial.
    Tewari P; Gupta D; Kumar A; Singh U
    J Postgrad Med; 2005; 51(4):260-4; discussion 264-5. PubMed ID: 16388166
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A comparison of the Laryngopharyngeal Examination blade and the English Macintosh laryngoscope blade using an intubating manikin: a prospective randomized crossover study.
    Ashfaque M; Mason J; Al-Shaikh B; Adegoke K
    Eur J Anaesthesiol; 2009 Nov; 26(11):917-22. PubMed ID: 19593148
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of direct and video-assisted views of the larynx during routine intubation.
    Kaplan MB; Hagberg CA; Ward DS; Brambrink A; Chhibber AK; Heidegger T; Lozada L; Ovassapian A; Parsons D; Ramsay J; Wilhelm W; Zwissler B; Gerig HJ; Hofstetter C; Karan S; Kreisler N; Pousman RM; Thierbach A; Wrobel M; Berci G
    J Clin Anesth; 2006 Aug; 18(5):357-62. PubMed ID: 16905081
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Straight blades improve visualization of the larynx while curved blades increase ease of intubation: a comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview blades.
    Arino JJ; Velasco JM; Gasco C; Lopez-Timoneda F
    Can J Anaesth; 2003 May; 50(5):501-6. PubMed ID: 12734161
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Callander laryngoscope blade modification is associated with a decreased risk of dental contact.
    Lee J; Choi JH; Lee YK; Kim ES; Kwon OK; Hastings RH
    Can J Anaesth; 2004 Feb; 51(2):181-4. PubMed ID: 14766698
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia.
    Xue FS; Zhang GH; Liu J; Li XY; Yang QY; Xu YC; Li CW
    Minerva Anestesiol; 2007 Sep; 73(9):451-7. PubMed ID: 17660737
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison between the GlideScope Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways - a pilot study.
    Armstrong J; John J; Karsli C
    Anaesthesia; 2010 Apr; 65(4):353-7. PubMed ID: 20402873
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Changes in the light intensity of the fiberoptic laryngoscope blade by steam sterilization.
    Nishiyama T
    Anesth Analg; 2007 Apr; 104(4):908-10. PubMed ID: 17377105
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A randomized comparison of the use of an optical compared with a rigid laryngoscope on the success rate of novices performing tracheal intubation.
    de Oliveira GS; Fitzgerald PC; Beckerly R; McCarthy RJ
    Anesth Analg; 2011 Mar; 112(3):615-8. PubMed ID: 21233492
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The Rusch ViewMax vs Macintosh laryngoscopy in human cadavers: impoved vocal cord visualization?
    Brillhart A; Dasti A; Matz W; Schrading WA
    Am J Emerg Med; 2009 Sep; 27(7):864-7. PubMed ID: 19683119
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Nasotracheal intubation with the McGrath videolaryngoscope in patients with difficult airway.
    Bamgbade OA; Onaolapo MH; Zuokumor PA
    Eur J Anaesthesiol; 2011 Sep; 28(9):673-4. PubMed ID: 21730864
    [No Abstract]   [Full Text] [Related]  

  • 37. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.
    Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H
    Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway--a randomized clinical trial.
    Vlatten A; Aucoin S; Litz S; Macmanus B; Soder C
    Paediatr Anaesth; 2009 Nov; 19(11):1102-7. PubMed ID: 19708910
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The McCoy straight blade does not improve laryngoscopy and intubation in normal infants.
    Iohom G; Franklin R; Casey W; Lyons B
    Can J Anaesth; 2004 Feb; 51(2):155-9. PubMed ID: 14766692
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Does the Miller blade truly provide a better laryngoscopic view and intubating conditions than the Macintosh blade in small children?
    Varghese E; Kundu R
    Paediatr Anaesth; 2014 Aug; 24(8):825-9. PubMed ID: 24690084
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.