183 related articles for article (PubMed ID: 21381372)
1. [Rate and level of contamination of potentially dangerous water supply facilities in Moscow region by Legionella pneumophila].
Tartakovskiĭ IS; Novokshonova IV; Sadretdinova OV; Gruzdeva OA; Aliapkina IuS; Karpova TI; Dronina IuE; Fokina VG; Shustrova NM
Zh Mikrobiol Epidemiol Immunobiol; 2010; (6):21-6. PubMed ID: 21381372
[TBL] [Abstract][Full Text] [Related]
2. [The hazards of hospitals and selected public buildings of Legionella pneumophila].
Sikora A; Kozioł-Montewka M; Wójtowicz-Bobin M; Gładysz I; Dobosz P
Pol Merkur Lekarski; 2013 Nov; 35(209):263-7. PubMed ID: 24575645
[TBL] [Abstract][Full Text] [Related]
3. [Examination of the contamination aetiological agent of legionellosis in the water supply systems of medical treatment facilities].
Gruzdeva OA; Tartakovskiĭ IS; Mar'in GG
Voen Med Zh; 2012 May; 333(5):34-8. PubMed ID: 22830115
[TBL] [Abstract][Full Text] [Related]
4. [Features of legionella biofilm formation in artificial and natural water systems].
Dronina IuE; Karpova TI; Sadretdinova OV; Didenko LV; Tartakovskiĭ IS
Zh Mikrobiol Epidemiol Immunobiol; 2012; (4):76-80. PubMed ID: 22937712
[TBL] [Abstract][Full Text] [Related]
5. Prevalence of Legionella strains in cooling towers and legionellosis cases in New Zealand.
Lau R; Maqsood S; Harte D; Caughley B; Deacon R
J Environ Health; 2013; 75(6):82-9. PubMed ID: 23397654
[TBL] [Abstract][Full Text] [Related]
6. [Using real-time polymerase chain reaction for detection of Legionella in objects of the environment].
Aliapkina IuS; Dronina IuE; Karpova TI; Pashko IuP; Varlamov DA; Alekseev IaI; Romanova IuM; Tartakovskiĭ IS
Zh Mikrobiol Epidemiol Immunobiol; 2009; (2):75-80. PubMed ID: 19459484
[TBL] [Abstract][Full Text] [Related]
7. Legionella pneumophila in Norwegian naval vessels.
Ahlén C; Aas M; Nor A; Wetteland PI; Johansen H; Sørbø T; Sommerfelt-Pettersen JK; Iversen OJ
Tidsskr Nor Laegeforen; 2013 Aug; 133(14):1445-8. PubMed ID: 23929291
[TBL] [Abstract][Full Text] [Related]
8. Water quality influences Legionella pneumophila determination.
Donohue MJ; Pham M; Brown S; Easwaran KM; Vesper S; Mistry JH
Water Res; 2023 Jun; 238():119989. PubMed ID: 37137207
[TBL] [Abstract][Full Text] [Related]
9. [Contamination of hot water supply in office buildings by Legionella pneumophila and some countermeasures].
Furuhata K; Takayanagi T; Danno N; Okada S; Kiya F
Nihon Koshu Eisei Zasshi; 1994 Nov; 41(11):1073-83. PubMed ID: 7873767
[TBL] [Abstract][Full Text] [Related]
10. Surveillance of hospital water and primary prevention of nosocomial legionellosis: what is the evidence?
O'Neill E; Humphreys H
J Hosp Infect; 2005 Apr; 59(4):273-9. PubMed ID: 15749313
[TBL] [Abstract][Full Text] [Related]
11. Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophila by culture in industrial cooling systems.
Touron-Bodilis A; Pougnard C; Frenkiel-Lebossé H; Hallier-Soulier S
J Appl Microbiol; 2011 Aug; 111(2):499-510. PubMed ID: 21624019
[TBL] [Abstract][Full Text] [Related]
12. Occurrence of Legionella in showers at recreational facilities.
De Filippis P; Mozzetti C; Amicosante M; D'Alò GL; Messina A; Varrenti D; Giammattei R; Di Giorgio F; Corradi S; D'Auria A; Fraietta R; Gabrieli R
J Water Health; 2017 Jun; 15(3):402-409. PubMed ID: 28598344
[TBL] [Abstract][Full Text] [Related]
13. Prevalence study of Legionella spp. contamination in ferries and cruise ships.
Azara A; Piana A; Sotgiu G; Dettori M; Deriu MG; Masia MD; Are BM; Muresu E
BMC Public Health; 2006 Apr; 6():100. PubMed ID: 16620388
[TBL] [Abstract][Full Text] [Related]
14. Hot water plumbing in residences and office buildings have distinctive risk of Legionella pneumophila contamination.
Donohue MJ; Mistry JH; Tucker N; Vesper SJ
Int J Hyg Environ Health; 2022 Aug; 245():114023. PubMed ID: 36058110
[TBL] [Abstract][Full Text] [Related]
15. DISTRIBUTION OF LEGIONELLA PNEUMOPHILA SEROGROUPS ISOLATED FROM WATER SYSTEMS OF PUBLIC FACILITIES IN BUSAN, SOUTH KOREA.
Hwang IY; Park EH; Park YK; Park SH; Sung GH; Park HY; Lee YC
Southeast Asian J Trop Med Public Health; 2016 May; 47(3):467-74. PubMed ID: 27405130
[TBL] [Abstract][Full Text] [Related]
16. Phylogenetic analysis of environmental Legionella pneumophila isolates from an endemic area (Alcoy, Spain).
Sánchez-Busó L; Olmos MP; Camaró ML; Adrián F; Calafat JM; González-Candelas F
Infect Genet Evol; 2015 Mar; 30():45-54. PubMed ID: 25511251
[TBL] [Abstract][Full Text] [Related]
17. Local Adaptation of Legionella pneumophila within a Hospital Hot Water System Increases Tolerance to Copper.
Bédard E; Trigui H; Liang J; Doberva M; Paranjape K; Lalancette C; Allegra S; Faucher SP; Prévost M
Appl Environ Microbiol; 2021 Apr; 87(10):. PubMed ID: 33674435
[TBL] [Abstract][Full Text] [Related]
18. Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of eastern Poland.
Sikora A; Wójtowicz-Bobin M; Kozioł-Montewka M; Magryś A; Gładysz I
Ann Agric Environ Med; 2015; 22(2):195-201. PubMed ID: 26094507
[TBL] [Abstract][Full Text] [Related]
19. Detection of Legionella pneumophila in water samples by species-specific real-time and nested PCR assays.
Fiume L; Bucci Sabattini MA; Poda G
Lett Appl Microbiol; 2005; 41(6):470-5. PubMed ID: 16305672
[TBL] [Abstract][Full Text] [Related]
20. [Legionellosis--a new infection in Poland].
Stypułkowska-Misiurewicz H; Pancer K
Przegl Epidemiol; 2002; 56(4):567-76. PubMed ID: 12666582
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]