These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 21385268)

  • 21. Apparent inappropriate shocks from an implantable cardioverter defibrillator:
    Moore DR; Kok LC; Vijayaraman P
    J Cardiovasc Electrophysiol; 2004 Jan; 15(1):116-7. PubMed ID: 15028086
    [No Abstract]   [Full Text] [Related]  

  • 22. Conductor externalization of the RIATA implantable cardioverter defibrillator lead: a challenging lead extraction requiring laser-powered sheath.
    Migliore F; Bertaglia E; Bontempi L; Verlato R; Leoni L; Iliceto S; Curnis A
    J Cardiovasc Med (Hagerstown); 2013 Oct; 14(10):755-6. PubMed ID: 23996009
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Insulation damage in a shock wire: an unexpected fluoroscopic image.
    Valk S; Luijten R; Jordaens L
    Pacing Clin Electrophysiol; 2010 Jun; 33(6):770-2. PubMed ID: 20070544
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads.
    Schmutz M; Delacrétaz E; Schwick N; Roten L; Fuhrer J; Boesch C; Tanner H
    Int J Cardiol; 2013 Jul; 167(1):254-7. PubMed ID: 22236515
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Inappropriate therapy of an implantable cardioverter-defibrillator--is it always an undesired event? A case report].
    Krzyzanowski K; Michałkiewicz D; Wierzbowski R; Gniłka A; Ryczek R; Orski Z; Kubik L
    Kardiol Pol; 2009 Aug; 67(8):927-9. PubMed ID: 19784895
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prevalence and predictors of cable extrusion and loss of electrical integrity with the Riata defibrillator lead.
    Shen S; Bhave P; Giedrimas E; Patel T; Arora R; Chicos AB; Goldberger JJ; Ilkhanoff L; Kim MH; Lin AC; Passman R; Lee R; Knight BP; Kim SS
    J Cardiovasc Electrophysiol; 2012 Nov; 23(11):1207-12. PubMed ID: 22697600
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Detection of a Riata™ insulation failure by the Medtronic Lead Integrity Alert™.
    Kneller J; Delacey W; Wood MA; Ellenbogen KA
    Europace; 2012 Aug; 14(8):1215-6. PubMed ID: 22371526
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.
    Saksena S; Tullo NG; Krol RB; Mauro AM
    Arch Intern Med; 1989 Oct; 149(10):2333-9. PubMed ID: 2802898
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pacing during a wide complex rhythm: implantable cardioverter defibrillator malfunction or not?
    Wood MA
    J Cardiovasc Electrophysiol; 2004 Jan; 15(1):114-5. PubMed ID: 15028085
    [No Abstract]   [Full Text] [Related]  

  • 32. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors.
    Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ
    Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Defibrillation coil reversal: a rare cause of abnormal noise and inappropriate shocks.
    Jeevanantham V; Levine E; Budzikowski AS; Shah AH; Daubert JP
    Pacing Clin Electrophysiol; 2008 Mar; 31(3):375-7. PubMed ID: 18307635
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Failure-free survival of the Durata defibrillator lead.
    Liu J; Patel D; Rattan R; Brumberg G; Saini A; Vaghasia N; Bazaz R; Adelstein E; Jain S; Saba S
    Europace; 2013 Jul; 15(7):1002-6. PubMed ID: 23376976
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A life-threatening arrhythmia induced by inappropriate activation of an implantable cardioverter defibrillator.
    Kadmon E; Kusniec J; Strasberg B
    Europace; 2009 Dec; 11(12):1716-8. PubMed ID: 19762330
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Unintentional protrusion and trapping of the screw-in helix of an implantable cardioverter defibrillator lead.
    Irie T; Kaneko Y; Nakajima T; Kurabayashi M
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):351. PubMed ID: 21385262
    [No Abstract]   [Full Text] [Related]  

  • 39. Impedance changes on defibrillation coils after atrial fibrillation ablation: lead damage or electromechanical interference?
    Vanga SR; Bommana S; Kroll M; Lakkireddy D
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e163-6. PubMed ID: 21029124
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Unrecognized failure of a narrow caliber defibrillation lead: the role of defibrillation threshold testing in identifying an unprotected individual.
    Leong DP; van Erven L
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e154-5. PubMed ID: 22309386
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.