These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 21389636)

  • 1. Angioscopic assessment of arterial repair following biodegradable polymer-coated biolimus A9-eluting stent implantation. - Comparison with durable polymer-coated sirolimus-eluting stent-.
    Awata M; Uematsu M; Sera F; Ishihara T; Watanabe T; Fujita M; Onishi T; Iida O; Ishida Y; Nanto S; Nagata S
    Circ J; 2011; 75(5):1113-9. PubMed ID: 21389636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.
    Ishihara T; Awata M; Iida O; Fujita M; Masuda M; Okamoto S; Nanto K; Kanda T; Tsujimura T; Uematsu M; Mano T
    Cardiovasc Interv Ther; 2019 Jan; 34(1):34-39. PubMed ID: 29335827
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy.
    Nojima Y; Adachi H; Ihara M; Kurimoto T; Okayama K; Sakata Y; Nanto S
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):204-209. PubMed ID: 30737973
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of early-phase arterial repair following cobalt-chrome everolimus-eluting stent and slow-release zotarolimus-eluting stent: an angioscopic study.
    Ishihara T; Iida O; Fujita M; Masuda M; Okamoto S; Nanto K; Kanda T; Tsujimura T; Sunaga A; Awata M; Nanto S; Uematsu M
    Cardiovasc Interv Ther; 2018 Apr; 33(2):163-168. PubMed ID: 28255728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heterogeneous arterial healing in patients following paclitaxel-eluting stent implantation: comparison with sirolimus-eluting stents.
    Awata M; Nanto S; Uematsu M; Morozumi T; Watanabe T; Onishi T; Iida O; Sera F; Minamiguchi H; Kotani J; Nagata S
    JACC Cardiovasc Interv; 2009 May; 2(5):453-8. PubMed ID: 19463470
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: five-year follow-up optical coherence tomography study.
    Kuramitsu S; Sonoda S; Yokoi H; Iwabuchi M; Nishizaki Y; Shinozaki T; Domei T; Hyodo M; Inoue K; Shirai S; Ando K; Nobuyoshi M
    Atherosclerosis; 2014 Nov; 237(1):23-9. PubMed ID: 25190308
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.
    Serruys PW; Farooq V; Kalesan B; de Vries T; Buszman P; Linke A; Ischinger T; Klauss V; Eberli F; Wijns W; Morice MC; Di Mario C; Corti R; Antoni D; Sohn HY; Eerdmans P; Rademaker-Havinga T; van Es GA; Meier B; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2013 Aug; 6(8):777-89. PubMed ID: 23968698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angioscopic assessments and clinical outcomes one year after polymer-free biolimus A9-coated coronary stent implantation.
    Tsujimura T; Ishihara T; Okuno S; Iida O; Kurata N; Asai M; Masuda M; Okamoto S; Nanto K; Kanda T; Matsuda Y; Hata Y; Mano T
    J Cardiol; 2021 May; 77(5):457-464. PubMed ID: 33121798
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparisons of detailed arterial healing response at seven months following implantation of an everolimus- or sirolimus-eluting stent in patients with ST-segment elevation myocardial infarction.
    Sawada T; Shinke T; Otake H; Mizoguchi T; Iwasaki M; Emoto T; Terashita D; Mizuguchi T; Okamoto H; Matsuo Y; Kim SK; Takarada A; Yokoyama M
    Int J Cardiol; 2013 Sep; 168(2):960-6. PubMed ID: 23164597
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
    Klauss V; Serruys PW; Pilgrim T; Buszman P; Linke A; Ischinger T; Eberli F; Corti R; Wijns W; Morice MC; di Mario C; van Geuns RJ; van Es GA; Kalesan B; Wenaweser P; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2011 Aug; 4(8):887-95. PubMed ID: 21851904
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Angioscopy study from a large patient population comparing sirolimus-eluting stent with biodegradable versus durable polymer.
    Chen SL; Xu T; Zhang JJ; Ye F; Hu ZY; Tian NL; Zhang YJ; Kotani J; Zhang JX
    Catheter Cardiovasc Interv; 2012 Sep; 80(3):420-8. PubMed ID: 21953920
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: comparative sequential assessment with optical coherence tomography until complete resorption of the polymer.
    Gutiérrez-Chico JL; Jüni P; García-García HM; Regar E; Nüesch E; Borgia F; van der Giessen WJ; Davies S; van Geuns RJ; Secco GG; Meis S; Windecker S; Serruys PW; di Mario C
    Am Heart J; 2011 Nov; 162(5):922-31. PubMed ID: 22093210
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).
    Vlachojannis GJ; Smits PC; Hofma SH; Togni M; Vázquez N; Valdés M; Voudris V; Slagboom T; Goy JJ; den Heijer P; van der Ent M
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1215-1221. PubMed ID: 28579236
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Angioscopic assessment of early phase arterial repair after paclitaxel-coated nitinol drug-eluting stent implantation in the superficial femoral artery.
    Ishihara T; Iida O; Awata M; Nanto K; Nanto S; Uematsu M
    Circ J; 2013; 77(7):1838-43. PubMed ID: 23595033
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents.
    Awata M; Kotani J; Uematsu M; Morozumi T; Watanabe T; Onishi T; Iida O; Sera F; Nanto S; Hori M; Nagata S
    Circulation; 2007 Aug; 116(8):910-6. PubMed ID: 17684153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early vascular healing after implantation of the polymer-free biolimus-eluting stent or the ultrathin strut biodegradable polymer sirolimus-eluting stent in patients with ST-segment elevation myocardial infarction.
    Hansen KN; Maeng M; Antonsen L; Maehara A; Jakobsen L; Ellert J; Terkelsen CJ; Ahlehoff O; Thim T; Fallesen CO; Noori M; Veien KT; Jensen LO; Christiansen EH
    Coron Artery Dis; 2022 May; 33(3):196-205. PubMed ID: 34985003
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.
    Tada N; Virmani R; Grant G; Bartlett L; Black A; Clavijo C; Christians U; Betts R; Savage D; Su SH; Shulze J; Kar S
    Circ Cardiovasc Interv; 2010 Apr; 3(2):174-83. PubMed ID: 20407114
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-month and 12-month serial follow-up.
    Kim BK; Hong MK; Shin DH; Kim JS; Ko YG; Choi D; Jang Y
    Int J Cardiol; 2013 Oct; 168(5):4617-23. PubMed ID: 23932862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Arterial repair 4 months after zotarolimus-eluting stent implantation observed on angioscopy.
    Ishihara T; Awata M; Sera F; Fujita M; Watanabe T; Iida O; Ishida Y; Nanto S; Uematsu M
    Circ J; 2013; 77(5):1186-92. PubMed ID: 23412803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of coronary angioscopic findings 8 months after stent implantation between two kinds of biodegradable polymer-coated and one durable polymer-coated drug-eluting stent.
    Yasumura K; Shutta R; Matsunaga-Lee Y; Nakamura D; Yano M; Yamato M; Egami Y; Sakata Y; Nishino M; Tanouchi J
    Coron Artery Dis; 2021 Mar; 32(2):91-95. PubMed ID: 32976243
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.